Manhattan · Block 837 · Lot 77 · 10018

58 West 36 Street

5 floors · 7 apartments · 6,390 sq ft · built 1905 · class C7 · owner of record: 58 West 36th Llc

15open violations
$365,000ECB/OATH penalties owed
0HPD class C (immediately hazardous)
47dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 47 days
Annual
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-12-30 (Accepted). Agency page

Dec 31, 2026
in 47 days
1 of 1 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 63 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 291 days
Registered through 2027-09-01
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1143 days
Next cycle year 2029

Open violations

ECB / OATH (22) · $365,000 owed
IssuedViolationHearingBalance
Sep 16, 2026Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. LACK OF REQUIRED NUMBER OF MEANS OF EGRESS FOR EVERY FLOOR PER BC 1018.1(2008 CODE); 27-366; BC 1021.1(2014 CODE); BC 1006.3(2022 CODE), FOR TRANSIENT USE
#35731176K
Dec 3, 2026
PENDING
$12,500
Sep 16, 2026Construction CLASS - 1
BC 907.2.8. FAILURE TO PROVIDE CLASS "J" FIRE ALARM SYSTEM FOR TRANSIENT USE AT APARTMENT #2A ON 2ND FLOOR.-PREVIOUS ECB VIOLATIONS #S 35725848N, 35720192R, 35688395J, 35688166X. REMEDY: DISCONTINUE ILLEGAL OCC
#35731178Y
Dec 3, 2026
$12,500
Sep 16, 2026Quality of Life CLASS - 1
PERMANENT DWELLING USED/CONVERTED FOR OTHER THAN PERMANENT RESIDENTIALPURPOSES. DEPARTMENT OF BUILDING RECORDS INDICATES PREMISES TO BE LEGALLY APPROVED AS A CLASS "A" MULTIPLE DWELLING. NOW, APARTMENT #2A ON 2
#35731175Z
Dec 3, 2026
$70,000
Sep 16, 2026Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. LACK OF A SYSTEM OF AUTOMATIC SPRINKLERS WHERE REQUIRED AS PER BC 903.2 AND 27-954,FOR TRANSIENT USE AT APARTMENT #2A ON 2ND FLOOR.-PREVIOUS ECB VIOLATIO
#35731177M
Dec 3, 2026
$12,500
May 5, 2026Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. LACK OF A SYSTEM OF AUTOMATIC SPRINKLERS WHERE IS REQUIRED AS PER BC 903.2 AND 27-954FOR TRANSIENT USE AT UNIT 2A AT 2ND FLOOR. PREV ECB: 35720191P. REMEDY
#35725847L
Jun 3, 2027
DEFAULT
$12,500
May 5, 2026Construction CLASS - 1
BC 907.2.8. FAILURE TO PROVIDE A CLASS "J" FIRE ALARM SYSTEM FOR TRANSIENT USE AT 2ND FLOOR, UNIT 2A. PREV ECB: 35720192R. REMEDY: DISCONTINUE ILLEGAL OCCUPANCY.
#35725848N
Jun 3, 2027
DEFAULT
$12,500
May 5, 2026Quality of Life CLASS - 1
PERMANENT DWELLING USED/CONVERTED FOR OTHER THAN PERMANENT RESIDENTIALPURPOSES. DOB RECORDS INDICATES PREMISES TO BE LEGALLY APPROVED AS A CLASS A MULTIPLE DWELLING. NOW, UNIT 2A AT THE 2ND FLOOR IS USED TRANSI
#35725845H
Jun 3, 2027
DEFAULT
$57,500
May 5, 2026Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. LACK OF REQUIRED NUMBER OF MEANS OF EGRESS FOR EVERU FLOOR PER BC 1018.1(2008 CODE); 27-366; BC 1021.1(2014 CODE); BC 1006.3(2022 CODE) FOR TRANSIENT USE A
#35725846J
Jun 3, 2027
DEFAULT
$12,500
Feb 20, 2026Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. FLOOR NUMBERINGSIGNS MISSING AND/OR DEFECTIVE PER BC 1019.1.7(2008 CODE); 27-392; BC 1022.8(2014 CODE); BC 1023.9(2022 CODE). UPON INSPECTION, IT WAS OBSER
#35725818M
May 28, 2026
IN VIOLATION
$2,500
Feb 20, 2026Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1(2004 CODE); 27-381; BC 1008.1(2022 CODE). UPON INSPECTION, THE MAIN EGRESS PATH
#35725819Y
May 28, 2026
IN VIOLATION
$2,500
Nov 28, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. LACK OF A SYSTEM OF AUTOMATIC SPRINKLER WHERE IS REQUIRED AS PER BC 903.2 AND 27-954 FOR TRANSIENT USE AT UNIT(2A) ON THE 2ND FLOOR-FRONT. PRE ECB #3568817
#35720191P
Oct 20, 2026
$6,250
Nov 28, 2025Quality of Life CLASS - 1
PERMANENT DWELLING USED/CONVERTED FOR OTHER THAN PERMANENT RESIDENTIALPURPOSES BY DOB RECORDS INDICATES PREMISES TO BE LEGALLY APPROVED AS ACLASS "A" MULTIPLE DWELLING NOW: PREMISES TO BE LEGALLY APPROVED AS A
#35720189X
Oct 20, 2026
$57,500
Nov 28, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. LACK OF REQUIRED NUMBER OF MEANS OF EGRESS FOR EVERY FLOOR PER BC 1018.1(2008 CODE); 27-366 BC 1021.1(2014 CODE); BC 1006.2(2022 CODE) FOR TRANSIENT USE
#35720190N
Oct 20, 2026
$6,250
Nov 28, 2025Construction CLASS - 1
BC 907.2.8. FAILURE TO PROVIDE A FIRE ALARM SYSTEM FOR TRANSIENT USE AT THE 2ND FLOOR FRONT UNIT(2A). PRE ECB #35688166X, 35688395J. REMEDY:DISCONTINUE ILLEGAL OCCUPANCY.
#35720192R
Oct 20, 2026
$2,500
Feb 21, 2025Construction CLASS - 1
B. C. 907.2.8. FAILURE TO PROVIDE CLASS "J" FIRE ALARM SYSTEM FOR TRANSIENT USE AT UNIT 2A ON THE 3RD FLOOR. PREVIOUS VIOLATION #35688166X. REMEDY: DISCONTINUE ILLEGAL OCCUPANCY.
#35688395J
May 20, 2027
$6,250
Feb 21, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER: LACK OF REQUIRED NUMBER OF MEANS OF EGRESS FOR EVERY FLOOR PER BC 1018.1(2008 CODE); 27-366; BC 1021.1(2014 CODE); BC 1006.3(2022 CODE) FOR TRANSIENT USE
#35688393X
May 20, 2027
$6,250
Feb 21, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: LACK OF A SYSTEM OF AUTOMATIC SPRINKLER WHERE IS REQUIRED AS PER B. C. 903.2 AND 27-954 FOR TRANSIENT USE AT UNIT 2A ON THE 3RD FLOOR. PREVIOUS VIOLATION #
#35688394H
May 20, 2027
$6,250
Feb 21, 2025Quality of Life CLASS - 1
PERMANENT DWELLING USED/CONVERTED FOR OTHER THAN PERMANENT RESIDENTIALPURPOSES. DOB RECORDS INDICATES PREMISES TO BE LEGALLY APPROVED AS A CLASS "A" MULTIPLE DWELLING NOW UNIT 2A ON THE 3RD FLOOR IS BEING USED
#35688392Y
May 20, 2027
$57,500
Jan 31, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: LACK OF REQUIRED NUMBER OF MEANS OF EGRESS FOR EVERY FLOOR PER BC 1018.1(2008 CODE); 27-366; 27-366; BC 1021.1(2014 CODE); BC 1006.3(2022 CODE) FOR TRANSIE
#35688165Y
Apr 15, 2027
$2,500
Jan 31, 2025Construction CLASS - 1
FAILURE TO PROVIDE A SYSTEM OF AUTOMATIC SPRINKLERS WHERE REQUIRED PERBC 903.2 AND 127-954 FOR TRANSIENT USE AT UNIT 2A. REMEDY: DISCONTINUEILLEGAL OCCUPANCY.
#35688170Z
Apr 15, 2027
$1,250
Jan 31, 2025Quality of Life CLASS - 2
PERMANENT DWELLING OFFERED/USED/CONVERTED FOR OTHER THEN PERMANENT RESIDENTIAL PURPOSES. DOB RECORDS INDICATED PREMISES TO BE LEGALLY APPROVED AS A CLASS "A" MULTIPLE DWELLING. NOW UNIT 2A ON THE 3RD FLOOR IS U
#35688164M
Apr 15, 2027
$2,500
Jan 31, 2025Construction CLASS - 1
BC 907.2.8. FAILURE TO PROVIDE CLASS "J" FIRE ALARM SYSTEM FOR UNIT 2AFOR TRANSIENT USE. REMEDY: DISCONTINUE ILLEGAL USE.
#35688166X
Apr 15, 2027
$2,500
DOB (6)
IssuedViolationStatus
Jun 30, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
#15362
DOB VIOLATION - ACTIVE
Jun 30, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
#35567
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
#16031
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
#36665
DOB VIOLATION - ACTIVE
Feb 24, 2017LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT
#00688
DOB VIOLATION - ACTIVE
Oct 1, 2015LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT
#00648
DOB VIOLATION - ACTIVE
DOB NOW Safety (6)
IssuedViolationStatus
Jun 30, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 30, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
Active
Feb 24, 2017Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT
Active
Oct 1, 2015Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT
Active
HPD (2) · C 0 · B 2 · A 0
IssuedClassViolationCorrect by
Sep 11, 2025B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LINTEL 1ST FROM EAST AT SOUTH AT BUILDING FRONT , 3rd STORYOct 16, 2025
Sep 11, 2025B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LINTEL 3RD FROM EAST AT SOUTH AT BUILDING FRONT , 3rd STORYOct 16, 2025

Issued in the last 120 days

DateSourceWhatNow
Sep 16, 2026ECBConstruction: FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. LACK OF REQUIRED NUMBER OF MEANS OF EGRESS FOR EVERY FLOOR PER BC 1018.1(2008 CODE); 27-366; BC 1021.1(2014 CODE); BC 1006.3(2022 CODE), FOR TRANSIENT USEOpen
Sep 16, 2026ECBConstruction: BC 907.2.8. FAILURE TO PROVIDE CLASS "J" FIRE ALARM SYSTEM FOR TRANSIENT USE AT APARTMENT #2A ON 2ND FLOOR.-PREVIOUS ECB VIOLATIONS #S 35725848N, 35720192R, 35688395J, 35688166X. REMEDY: DISCONTINUE ILLEGAL OCCClosed
Sep 16, 2026ECBQuality of Life: PERMANENT DWELLING USED/CONVERTED FOR OTHER THAN PERMANENT RESIDENTIALPURPOSES. DEPARTMENT OF BUILDING RECORDS INDICATES PREMISES TO BE LEGALLY APPROVED AS A CLASS "A" MULTIPLE DWELLING. NOW, APARTMENT #2A ON 2Closed
Sep 16, 2026ECBConstruction: FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. LACK OF A SYSTEM OF AUTOMATIC SPRINKLERS WHERE REQUIRED AS PER BC 903.2 AND 27-954,FOR TRANSIENT USE AT APARTMENT #2A ON 2ND FLOOR.-PREVIOUS ECB VIOLATIOClosed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 14, 2026, 4:21 AM ET. BBL 1008370077.