Brooklyn · Block 6598 · Lot 1 · 11204

58 Avenue O

3 floors · 5 apartments · 5,100 sq ft · built 1926 · class S5 · owner of record: 58 Ave. O Llc

38open violations
$0ECB/OATH penalties owed
6HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 66 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 82 days
Annual
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 431 days
Next cycle year 2027
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-01-30 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (0)

None open.

DOB (1)
IssuedViolationStatus
Feb 10, 1997LOCAL LAW 62/91 - BOILERS

#30213
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Feb 10, 1997Boiler LL6291
Active
HPD (36) · C 6 · B 19 · A 11
IssuedClassViolationCorrect by
Jun 12, 2008BApt 2F · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING THRU OUT 2 STY FRONT APT 2F. , SECTION '' ''Jul 17, 2008
Jun 12, 2008BApt 2F · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS & CEILING 2 STY NORTH APT 2F. , SECTION '' ''Jul 17, 2008
Jun 12, 2008BApt 2F · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING 2 STY NORTH APT 2F BATHROOM. , SECTION '' ''Jul 17, 2008
Jun 12, 2008AApt 2F · SECTION 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION DROP CEILING INSTALLED 2 STY NORTH APT 2F BATHROOM. , SECTION '' ''Sep 15, 2008
Jun 12, 2008AApt 2R · SECTION 27-2005 ADM CODE REFIT DOOR ENTRANCE 2 STY APT 2R. , SECTION '' ''Sep 15, 2008
Jun 12, 2008BApt 2R · SECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ENTRANCE 2 STY APT 2R. , SECTION '' ''Jul 17, 2008
Jun 12, 2008AApt 2R · SECTION 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION DROP CEILING 2 STY REAR APT 2R KITCHEN. , SECTION '' ''Sep 15, 2008
Jun 12, 2008BApt 2F · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS & CEILINGS THRU OUT 2 STY FRONT APT 2F. LOCATED AT APT 2FJul 17, 2008
Jun 12, 2008AApt 2F · SECTION 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION DROP CEILING 2 STY FRONT APT 2F BATHROOM. LOCATED AT APT 2FSep 15, 2008
Jun 12, 2008AApt 2R · SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING 2 STY REAR APT 2R CENTER ROOM. , SECTION '' ''Sep 15, 2008
Jun 12, 2008AApt 2F · SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING 2 STY FRONT APT 2F FRONT NORTHEAST ROOM. LOCATED AT APT 2FSep 15, 2008
Jun 12, 2008CApt 3F · SECTION 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTELINE WASHBASIN 3 STY APT 3F BATHROOM ER1. , SECTION '' ''Jun 18, 2008
Jun 12, 2008BApt 3F · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MECHANICAL STOPPER TO WASTELINE WASHBASIN 3 STY APT 3F BATHROOM. , SECTION '' ''Jul 17, 2008
Jun 12, 2008BApt 2F · SECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ENTRANCE TO 2 STY APT 2F FRONT WEST. , SECTION '' ''Jul 17, 2008
Jul 28, 2006ASECTION 27-2005 ADM CODE REFIT DOOR BULKHEAD TO ROOF.Nov 24, 2006
Jul 28, 2006AApt 3F · SECTION 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION DROP CEILING BATHROOM 3 STY APT 3F. , SECTION '' ''Nov 24, 2006
Jul 28, 2006AApt 3F · SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILINGS THRU OUT 3 STY APT 3F. LOCATED AT APT 3FNov 24, 2006
Jul 28, 2006AApt 3F · SECTION 27-2026 ADM CODE RESET, SO AS TO SECURE A PROPER AND TIGHT CONNECTION, THE WATER CLOSET BOWL BATHROOM 3 STY APT 3F. LOCATED AT APT 3FNov 24, 2006
Jul 28, 2006AApt 3F · SECTION 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION DROPPED CEILING BATHROOM 3 STY APT 3F LOCATED AT APT 3FNov 24, 2006
Jul 23, 2001BApt 3F · SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS SINK 3 STY APT 3F KITCHEN. , SECTION '' ''Sep 1, 2001
Jul 23, 2001BApt 3F · SECTION 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTELINE KITCHEN SINK 3 STY APT 3F. , SECTION '' ''Sep 1, 2001
Jul 23, 2001BApt 3F · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS & CEILINGS 3 STY APT 3F NORTHEAST ROOM. , SECTION '' ''Sep 1, 2001
Jul 23, 2001BApt 3F · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF MILDEW WALLS CENTER ROOM 3 STY APT 3F. , SECTION '' ''Sep 1, 2001
Jul 23, 2001BApt 3F · SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS WASHBASIN BATHROOM 3 STY APT 3F. , SECTION '' ''Sep 1, 2001
Jul 23, 2001BApt 3F · SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS BATHTUB BATHROOM 3 STY APT 3F. , SECTION '' ''Sep 1, 2001
Jul 23, 2001BApt 3F · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SHUT OFF VALVE HOT WATER BATHTUB BATHROOM 3 STY APT 3F. , SECTION '' ''Sep 1, 2001
Jul 23, 2001BApt 3 · SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC WALL TILES BATHROOM 3 STY APT 3. LOCATED AT APT 3Sep 1, 2001
Jul 23, 2001BApt 3F · SECTION 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK CEILINGS OVER KITCHEN AND BATHROOM 3 STY APT 3F LOCATED AT APT 3FSep 1, 2001
Jul 23, 2001CSECTION 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM NEAR MAILBOXES 1 STY PUBLIC HALL.Aug 3, 2001
Jul 23, 2001CSECTION 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM ENTRANCE BOILER ROOM CELLAR.Aug 3, 2001
Jul 23, 2001BSECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ENTRANCE 1 STY PUBLIC HALL VESTIBULE.Sep 1, 2001
Jul 23, 2001BSECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCKING ASSEMBLY VESTIBULE DOOR 1 STY PUBLIC HALL.Sep 1, 2001
Jul 23, 2001CApt 3F · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING MISSING GLASS LOWER SASH KITCHEN WINDOW 3 STY APT 3F ER1. , SECTION '' ''Aug 3, 2001
Jul 23, 2001CApt 3F · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING MISSING GLASS LOWER SASH NORTH WINDOW CENTER ROOM 3 STY APT 3F ER1. , SECTION '' ''Aug 3, 2001
Jul 23, 2001CApt 3F · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING MISSING GLASS LOWER SASH EAST WINDOW NORTHEAST ROOM 3 STY APT 3F ER1. , SECTION '' ''Aug 3, 2001
Jul 23, 2001BApt 3F · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE CRACKED GLASS UPPER SASH KITCHEN WINDOW 3 STY APT 3F. , SECTION '' ''Sep 1, 2001