2 floors · 5,820 sq ft · built 2021 · class O7 · owner of record: King Wk Property Management Inc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 412 days | Next cycle year 2027 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 19, 2026 | Construction CLASS - 2 AT THE TIME OF INSPECTION OF A PROPOSED 3-STORY NEW BUILDING, I OBSERVED A SIDEWALK SHED ERECTED ALONG A DRIVEWAY. VERTICAL POSTS ON BOTH SIDES OF THE DRIVEWAY LACKED REQUIRED HIGHLY VISIBLE MARKINGS, CREATING #39559375R | Nov 24, 2026 PENDING | $2,400 |
| Sep 19, 2026 | Construction CLASS - 2 AT THE TIME OF INSPECTION OF A 3-STORY NEW BUILDING, I OBSERVED THE ERECTED SIDEWALK SHED AT EXPOSURE 1 MISSING THE REQUIRED PARAPET INFORMATION PANEL. THIS CONDITION MAY IMPEDE FIRST RESPONDERS FROM READILY ID #39559374P | Nov 24, 2026 PENDING | $1,250 |
| Sep 16, 2026 | Construction CLASS - 1 UPON INSPECTION, AN OPEN CONSTRUCTION SITE WAS OBSERVED. A SIGNIFICANT AMOUNT OF OVERGROWN BRUSH AND VEGETATION PRESENT ON EXP 3, CREATING HAZARDOUS CONDITIONS FOR WORKERS ACCESSING AND PERFORMING WORK AT THAT #39559287R | Nov 24, 2026 PENDING | $2,500 |
| Sep 16, 2026 | Construction CLASS - 1 OBSERVED: CS PRESENT, STRUCTURAL STEEL FRAIMING GOING ON 2ND AND 3RD LEVEL UPON VISUAL INSPECTION NOTED THERE MISSING BOLTS, PLACED NOT TIGHT ENOUGH., AND APPROVED DRAWINGS MOMENT CONECTION DETAIL 3/S201 SHOWIN #39559275J | Nov 24, 2026 PENDING | $2,500 |
| Sep 16, 2026 | Unknown CLASS - 1 3308.5 & 3308.5.2OBSERVED : ACTIVE SITE CS PRESENT UPON INSPECTION NOTED DEBRIS NETTING ON SECOND FLOOR INADECUATE AND CONTRARY TO SSP PLANS PG 3 OF 8 MIISING ON 2ND FLOOR EXP 2,CORNER EXP 1-4, EXP 1-2 . STOP A #39559283J | Nov 24, 2026 PENDING | $5,000 |
| Sep 16, 2026 | Unknown CLASS - 1 BC 3309.1 & BC3301.1.1 OBSERVED: ACTIVE SITE WORKING ON 2ND AND 3RD LEVEL CS PRESENT UPON INSPECTION NOTED ADJACENT PROPERTY WINDOWS AND SITE EXP 4 HAS BEEN NOT PROTECTED AS SOON GET 2ND FLOOR LEVEL CONFORMIN #39559277N | Nov 24, 2026 PENDING | $5,000 |
| Sep 16, 2026 | Unknown CLASS - 2 BC3307.7 ., BC3307.7.1 & 28-105.1 .OBSERVED ACTIVE SITE WITH EXPIRE FENCE PERMIT ALSO NOTED FENCE DRAWINGS HAS BEEN NOT SUBMITED AND APPROVED BY DEPARTMENT OF BUILDINGS . STOP ALL WORK IMMEDIATELLY RENEW PERMIT #39559282H | Nov 24, 2026 PENDING | $1,250 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Oct 28, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 28, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 28, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 28, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 28, 2026 | DOB Safety | AEUHAZ: | Open |
| Oct 28, 2026 | DOB Safety | AEUHAZ: | Open |
| Oct 28, 2026 | DOB Safety | AEUHAZ: | Open |
| Oct 28, 2026 | DOB Safety | AEUHAZ: | Open |
| Sep 19, 2026 | ECB | Construction: AT THE TIME OF INSPECTION OF A PROPOSED 3-STORY NEW BUILDING, I OBSERVED A SIDEWALK SHED ERECTED ALONG A DRIVEWAY. VERTICAL POSTS ON BOTH SIDES OF THE DRIVEWAY LACKED REQUIRED HIGHLY VISIBLE MARKINGS, CREATING | Open |
| Sep 19, 2026 | ECB | Construction: AT THE TIME OF INSPECTION OF A 3-STORY NEW BUILDING, I OBSERVED THE ERECTED SIDEWALK SHED AT EXPOSURE 1 MISSING THE REQUIRED PARAPET INFORMATION PANEL. THIS CONDITION MAY IMPEDE FIRST RESPONDERS FROM READILY ID | Open |
| Sep 16, 2026 | ECB | Construction: UPON INSPECTION, AN OPEN CONSTRUCTION SITE WAS OBSERVED. A SIGNIFICANT AMOUNT OF OVERGROWN BRUSH AND VEGETATION PRESENT ON EXP 3, CREATING HAZARDOUS CONDITIONS FOR WORKERS ACCESSING AND PERFORMING WORK AT THAT | Open |
| Sep 16, 2026 | ECB | Construction: OBSERVED: CS PRESENT, STRUCTURAL STEEL FRAIMING GOING ON 2ND AND 3RD LEVEL UPON VISUAL INSPECTION NOTED THERE MISSING BOLTS, PLACED NOT TIGHT ENOUGH., AND APPROVED DRAWINGS MOMENT CONECTION DETAIL 3/S201 SHOWIN | Open |
| Sep 16, 2026 | ECB | Unknown: 3308.5 & 3308.5.2OBSERVED : ACTIVE SITE CS PRESENT UPON INSPECTION NOTED DEBRIS NETTING ON SECOND FLOOR INADECUATE AND CONTRARY TO SSP PLANS PG 3 OF 8 MIISING ON 2ND FLOOR EXP 2,CORNER EXP 1-4, EXP 1-2 . STOP A | Open |
| Sep 16, 2026 | ECB | Unknown: BC 3309.1 & BC3301.1.1 OBSERVED: ACTIVE SITE WORKING ON 2ND AND 3RD LEVEL CS PRESENT UPON INSPECTION NOTED ADJACENT PROPERTY WINDOWS AND SITE EXP 4 HAS BEEN NOT PROTECTED AS SOON GET 2ND FLOOR LEVEL CONFORMIN | Open |
| Sep 16, 2026 | ECB | Unknown: BC3307.7 ., BC3307.7.1 & 28-105.1 .OBSERVED ACTIVE SITE WITH EXPIRE FENCE PERMIT ALSO NOTED FENCE DRAWINGS HAS BEEN NOT SUBMITED AND APPROVED BY DEPARTMENT OF BUILDINGS . STOP ALL WORK IMMEDIATELLY RENEW PERMIT | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 14, 2026, 3:05 PM ET. BBL 4074510045.