Manhattan · Block 1305 · Lot 7501 · 10022

569 Lexington Avenue

19 floors · 307,939 sq ft · built 1961 · class RC · owner of record: Unavailable Owner

12open violations
$3,155ECB/OATH penalties owed
0HPD class C (immediately hazardous)
47dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 47 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $105,000 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2027
in 99 days
No Cycle 10 report on record yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 307,939 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 168 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 168 days
Annual filing
Energy audit and retro-commissioning (2035) Likely applies
Local Law 87 · Calendar year 2035
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1305). Agency page

Dec 31, 2035
in 3334 days
Next due 2035

Open violations

ECB / OATH (2) · $3,155 owed
IssuedViolationHearingBalance
Aug 12, 2026Elevators CLASS - 2
CLASS 2 ITEMS: CATEGORY 1 TEST TAG EXPIRED. CURRENT ANNUAL CAT 1 TEST CERTIFICATION NOT MAINTAINED/DISPLAYED AS REQUIRED.ASME A17.1-2013, SECTION 8.6.1.7.3 (TEST RECORDS/TAG REQUIREMENTS) EXCESSIVE CLEARANCE OB
#39200349M
Oct 22, 2026
DEFAULT
$655
May 19, 2026Unknown CLASS - 1
FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION. AT THE TIME OF INSPECTION ON AN ACTIVE PARKING STRUCTURE CONSISTING OF TWO LEVEL OBSERVED CRACKED AT MULTIPLE LOCATIONS ON THE LOWER LEVEL AND UPPER LEVE
#35726942Y
Sep 24, 2026
IN VIOLATION
$2,500
DOB (2)
IssuedViolationStatus
Jan 11, 2024CONSTRUCTION
EMERGENCY WORK ORDER ACTIVE PARKING STUCTURE OF 5 LEVEL BELOW 23FL BUILDING.SPALLING CONCRETE/EXPOSED REBAR VISIBLE CORROSION&RUSTING OF REINFORCEMENT ALL LEVEL-1 SUB-CELLAR CELLING@SEVERAL LOC.CAUSING IMMED HAZ TO TRAFFIC.REMEDY:RETAIN RDP TO DIR.&SUPERV.IMMED.INSTALL.SAFETY MEASURES SUCH AS STABLI
#LL10601MK
DOB VIOLATION - ACTIVE
Nov 20, 2008ELEVATOR

#9011/285543
DOB VIOLATION - ACTIVE
DOB NOW Safety (9)
IssuedViolationStatus
Oct 29, 2026Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction
Active
Oct 29, 2026Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction
Active
Oct 29, 2026Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction
Active
Oct 2, 2026Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2025 Cat1 Test Report
Active
Aug 12, 2026AEUHAZ FTC-AEU-HAZ
Active
Oct 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle C (premises is in Community District 6)
Active
Aug 29, 2025Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Report
Active
Dec 31, 2024Parking Structures FTC-PS-UNSAFE
Unsafe report of parking structures filed.
Active
Sep 11, 2024Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Report
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Oct 29, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of CorrectionOpen
Oct 29, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of CorrectionOpen
Oct 29, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of CorrectionOpen
Oct 2, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Cat1 Test ReportOpen
Aug 12, 2026ECBElevators: CLASS 2 ITEMS: CATEGORY 1 TEST TAG EXPIRED. CURRENT ANNUAL CAT 1 TEST CERTIFICATION NOT MAINTAINED/DISPLAYED AS REQUIRED.ASME A17.1-2013, SECTION 8.6.1.7.3 (TEST RECORDS/TAG REQUIREMENTS) EXCESSIVE CLEARANCE OBClosed
Aug 12, 2026DOB SafetyAEUHAZ: Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 14, 2026, 2:44 PM ET. BBL 1013057501.