19 floors · 307,939 sq ft · built 1961 · class RC · owner of record: Unavailable Owner
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 47 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $105,000 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2027 in 99 days | No Cycle 10 report on record yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 307,939 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 168 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 168 days | Annual filing |
| Energy audit and retro-commissioning (2035) Likely applies Local Law 87 · Calendar year 2035 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1305). Agency page | Dec 31, 2035 in 3334 days | Next due 2035 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 12, 2026 | Elevators CLASS - 2 CLASS 2 ITEMS: CATEGORY 1 TEST TAG EXPIRED. CURRENT ANNUAL CAT 1 TEST CERTIFICATION NOT MAINTAINED/DISPLAYED AS REQUIRED.ASME A17.1-2013, SECTION 8.6.1.7.3 (TEST RECORDS/TAG REQUIREMENTS) EXCESSIVE CLEARANCE OB #39200349M | Oct 22, 2026 DEFAULT | $655 |
| May 19, 2026 | Unknown CLASS - 1 FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION. AT THE TIME OF INSPECTION ON AN ACTIVE PARKING STRUCTURE CONSISTING OF TWO LEVEL OBSERVED CRACKED AT MULTIPLE LOCATIONS ON THE LOWER LEVEL AND UPPER LEVE #35726942Y | Sep 24, 2026 IN VIOLATION | $2,500 |
| Issued | Violation | Status |
|---|---|---|
| Jan 11, 2024 | CONSTRUCTION EMERGENCY WORK ORDER ACTIVE PARKING STUCTURE OF 5 LEVEL BELOW 23FL BUILDING.SPALLING CONCRETE/EXPOSED REBAR VISIBLE CORROSION&RUSTING OF REINFORCEMENT ALL LEVEL-1 SUB-CELLAR CELLING@SEVERAL LOC.CAUSING IMMED HAZ TO TRAFFIC.REMEDY:RETAIN RDP TO DIR.&SUPERV.IMMED.INSTALL.SAFETY MEASURES SUCH AS STABLI #LL10601MK | DOB VIOLATION - ACTIVE |
| Nov 20, 2008 | ELEVATOR #9011/285543 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 29, 2026 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Active |
| Oct 29, 2026 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Active |
| Oct 29, 2026 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Active |
| Oct 2, 2026 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Report | Active |
| Aug 12, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle C (premises is in Community District 6) | Active |
| Aug 29, 2025 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Report | Active |
| Dec 31, 2024 | Parking Structures FTC-PS-UNSAFE Unsafe report of parking structures filed. | Active |
| Sep 11, 2024 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Report | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Open |
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Open |
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Report | Open |
| Aug 12, 2026 | ECB | Elevators: CLASS 2 ITEMS: CATEGORY 1 TEST TAG EXPIRED. CURRENT ANNUAL CAT 1 TEST CERTIFICATION NOT MAINTAINED/DISPLAYED AS REQUIRED.ASME A17.1-2013, SECTION 8.6.1.7.3 (TEST RECORDS/TAG REQUIREMENTS) EXCESSIVE CLEARANCE OB | Closed |
| Aug 12, 2026 | DOB Safety | AEUHAZ: | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 14, 2026, 2:44 PM ET. BBL 1013057501.