Brooklyn · Block 1137 · Lot 53 · 11238

564 Vanderbilt Avenue

4 floors · 8 apartments · 7,008 sq ft · built 1889 · class C7 · owner of record: 564 Vanderbilt Avenue Llc

7open violations
$0ECB/OATH penalties owed
2HPD class C (immediately hazardous)
66dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 66 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 66 days
Annual
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-12-24 (Accepted). Agency page

Dec 31, 2026
in 66 days
1 of 1 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 82 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 310 days
Registered through 2027-09-01

Open violations

ECB / OATH (2)
IssuedViolationHearingBalance
Oct 2, 2003Construction Non-Hazardous
FAILURE TO MAINTAIN BUILDING. DEFECTS IS: (3) 3X10 WOOD BEAMS ROTTEN (2) AT REAR BATHROOM AND (1) AT MIDDLE SECTION OF CELLAR LEVEL, ALSO SECTION OF SHEETROCK/PLASTER CEILING MISSING. EXTERIOR BRICKWORK BULG-
#34412602J
Nov 24, 2003
WRITTEN OFF
$0
Jan 17, 2001Boilers Non-Hazardous
21B 49A 49B 49C 49A)NO CHECK VALVE (BACK FLOW PREVENTOR) ON BOILER FEED LINE.49B).TO PIPE SAFTEY VALVE TO FLOOR.49C)TO CLEAN BOILER ROOM.
#32020824J
Mar 5, 2001
WRITTEN OFF
$0
DOB (1)
IssuedViolationStatus
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#39997
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (4) · C 2 · B 2 · A 0
IssuedClassViolationCorrect by
Dec 2, 2024C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR FRAME AT BOILER ROOM DOOR AT BOILER ROOMDec 16, 2024
Dec 2, 2024C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR LEADING TO CELLAR AT PUBLIC HALL, 1st STORYDec 16, 2024
Sep 19, 2014BApt 1L · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). WHICH IS INOPERATIVE LOCATED AT APT 1L, 1st STORY, APARTMENT AT SOUTHOct 24, 2014
Sep 19, 2014BApt 1L · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR WHICH IS INOPERATIVE LOCATED AT APT 1L, 1st STORY, APARTMENT AT SOUTHOct 24, 2014

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 8:42 AM ET. BBL 3011370053.

Look up another building