Brooklyn · Block 3802 · Lot 15 · 11207

564 Dumont Avenue

5 floors · 190,000 sq ft · built 1950 · class W1 · owner of record: Nyc Department Of Education

13open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
185dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 64 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 190,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 185 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 185 days
Annual filing
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1160 days
Next cycle year 2029
Energy audit and retro-commissioning (2032) Likely applies
Local Law 87 · Calendar year 2032
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 3802). Agency page

Dec 31, 2032
in 2256 days
Next due 2032
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-08-18 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (8)
IssuedViolationHearingBalance
Mar 24, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1; 27-371(J). AT THE TIME OF INSPECTION, THE FOLLOWING DOORS HAD TURN KNOB HANDLES:-213,303, 302, 402, 4
#35727585J
Apr 17, 2026
POP/IN-VIO
$0
Mar 24, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT THE TIME OF INSPECTION, THE FOLLOWING DOORS WERE NOT SELF-CLOSING PROPERLY:-VESTIBULE DOOR AT EXIT #C AUDITORIUM EXIT DOOR TO EXIT DISCHARGES "C". VESTI
#35727584H
Apr 17, 2026
POP/IN-VIO
$0
Mar 24, 2026Construction CLASS - 2
28-301.1. UNLAWFUL DISPLAY OF ARTWORK IN CORRIDORS GREATER THAN 20% PER FDNY 2008 CODE; FC 803.3.2. AT THE TIME OF INSPECTION, EXCESSIVE ARTWORK WAS OBSERVED IN CORRIDOR NEXT TO ROOM B1. REMEDY: COMPLY WITH NOT
#35727590Y
Apr 17, 2026
POP/IN-VIO
$0
Mar 24, 2026Construction CLASS - 2
RE-ISSUED 35692078H. AT THE TIME OF INSPECTION, TEMPORARY CERTIFICATE OF OCCUPANCY THAT EXPIRED ON 6/18/1973 WAS NOT RENEWED OR FINALIZED. REMEDY: OBTAIN VALID C OF O OR DISCONTINUE ILLEGAL OCCUPANCY.
#35727591X
Apr 17, 2026
POP/IN-VIO
$0
Mar 24, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. AT THE TIME OF INSPECTION, AREAS OF COUNTER FLASHING WAS MISSING. REMEDY: MAINTAIN EXTERIOR BUILDING WALL.
#35727589R
Apr 17, 2026
POP/IN-VIO
$0
Mar 24, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT THE TIME OF INSPECTION, VESTIBULE OF EXIT #9 HAD SPALLING AND EFFLORESCENCE, EXIT #8 DOOR FRAME WAS CORRODED, BROKEN PANEL TRANSOM @ STAIRCASE "F" ON 2N
#35727588P
Apr 17, 2026
POP/IN-VIO
$0
Mar 24, 2026Construction CLASS - 2
EXIT DOOR NOT SELF-CLOSING. AT THE TIME OF INSPECTION, THE FOLLOWING EXIT DISCHARGE DOORS WERE NOT SELF-CLOSING PROPERLY:-EXIT #6, #8, #7(COMING OFF HINGES) #2. REMEDY: REPAIR/REPLACE DOOR.
#35727586L
Apr 17, 2026
POP/IN-VIO
$0
Apr 7, 2025Construction CLASS - 2
ALTERED/CHANGED BUILDING OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY AS PER 28-118.3.1-28-118.3.2 RECORD C OF O #206098 EXPIRED ON 06/18/1973 TEMPORARY. NO RECORD OF RENEWAL OR FINALIZED. NO RECORD OF ALT
#35692078H
May 1, 2025
POP/IN-VIO
$0
DOB (0)

None open.

DOB NOW Safety (5)
IssuedViolationStatus
Dec 15, 2025Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device
Active
Dec 15, 2025Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 28, 2026, 11:12 AM ET. BBL 3038020015.

Look up another building