Brooklyn · Block 2328 · Lot 18 · 11211

556 Driggs Avenue

3 floors · 4 apartments · 5,000 sq ft · built 1910 · class S4 · owner of record: 556 Driggs Llc

18open violations
$0ECB/OATH penalties owed
1HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 63 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 63 days
Annual
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-08-01 (Accepted). Agency page

Dec 31, 2026
in 63 days
1 of 1 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 79 days
Annual
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 794 days
Next cycle year 2028

Open violations

ECB / OATH (3)
IssuedViolationHearingBalance
Jul 1, 2025Boilers CLASS - 2
FAILURE TO FILE REQUIRED ANNUAL BOILER INSPECTION REPORTS FOR LOW-PRESSURE BOILER 30000115220N0001 IN ACCORDANCE WITH THE RULES OF THE DEPARTMENT. 1RCNY 103-01(D)(1) REQUIRES THAT AN ANNUAL INSPECTION REPORT FO
#37035616Z
Nov 19, 2025
IN VIOLATION
$0
Jun 10, 2019Construction CLASS - 3
AS PER THE CITY RECORDS (CERTIFICATE OF OCCUPANCY# 212237 DATED: MAY 15, 1975) THE LEGAL USE FOR THE GROUND IS "OPEN ACCESSORY PARKING FOR THREE CARS. OBSERVED ONE STORY STRUCTURE AT EXPOSURE#4 (NORTH 7 ST ELEV
#39003927M
Jul 29, 2019
STIPULATION/IN-VIO
$0
Feb 2, 2008HPD Non-Hazardous
WORK W/O PERMIT. WORK NOTED: AT REAR AT THAT PREMISES CONSTRUCTED ROOFWOOD JOISTS APPR. SIZE OF REAR YARD 50FT X 20FT OVER CONSTRUCTED SLIDINGG ALUMINUM W/GLASS ROOF. ALL WORK DONE W/O APPROVALS & PERMITS. REME
#34623422M
Mar 31, 2008
STIPULATION/IN-VIO
$0
DOB (2)
IssuedViolationStatus
Aug 23, 2014CONSTRUCTION
WORK WITHOUT A PERMIT; WORK NOTED 1ST FLR REAR ADD AND EXTENSION TO THE BUILDING STRUCTURE APPROX. 20 X 50 MADE OF MASONRY WITH ROOF AND DOOR./REMEDY; OBTAIN A PERMIT OR RESTORE PREMISES TO PRIOR LEGAL CONDITION
#0102JL
VIOLATION WORK WITHOUT PERMIT - ACTIVE
Dec 13, 2011LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT
#11061
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Dec 13, 2011Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT
Active
HPD (12) · C 1 · B 7 · A 4
IssuedClassViolationCorrect by
May 19, 2021B§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF FLOWER POTS AT 2ND AND 3RD STORY BALCONIES AT NORTH STACK AT FIRE ESCAPEJun 23, 2021
May 19, 2021BApt 2F · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT 2F, 2nd STORY, APARTMENT AT EASTJun 23, 2021
May 19, 2021BApt 2F · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 2F, 2nd STORY, APARTMENT AT EASTJun 23, 2021
May 19, 2021B§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL LIGHT FIXTURE AT NORTH WALL IN THE VESTIBULE AT PUBLIC HALL, 1st STORYJun 23, 2021
May 17, 2021A§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD.Aug 20, 2021
May 17, 2021A§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTEDAug 20, 2021
May 17, 2021B§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES FLOWER POTS AT 2ND AND 3RD STORY BALCONIES, STACK AT BUILDING NORTH YARD AT FIRE ESCAPEJun 21, 2021
May 17, 2021A§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING.Aug 20, 2021
May 17, 2021A§ 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX , AT PUBLIC HALL, 1st STORYAug 20, 2021
May 17, 2021C§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM , AT PUBLIC HALL, 1st STORYMay 23, 2021
Aug 4, 2010B§ 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS AT BUILDING ENTRANCE , 1st STORYSep 8, 2010
Aug 19, 2008BD26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CEMENT MORTAR CLG BOILER ROOM CELLAR R42.Sep 23, 2008

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 29, 2026, 1:48 AM ET. BBL 3023280018.