Brooklyn · Block 7232 · Lot 81 · 11223

556 Avenue Z

6 floors · 120 apartments · 97,440 sq ft · built 1951 · class D1 · owner of record: Beach Haven Group Llc

41open violations
$33,750ECB/OATH penalties owed
14HPD class C (immediately hazardous)
58dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 58 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 58 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 74 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 97,440 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 179 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 179 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 302 days
Registered through 2027-09-01
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 13 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1154 days
Next cycle year 2029
Energy audit and retro-commissioning (2032) Likely applies
Local Law 87 · Calendar year 2032
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 7232). Agency page

Dec 31, 2032
in 2250 days
Next due 2032
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-10-22 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (9) · $33,750 owed
IssuedViolationHearingBalance
Sep 8, 2026Elevators CLASS - 1
CEASE USE ITEM: INOPERATIVE ZONE LOCK RESTRICTOR (2.14.5.7.1.). CLASS 2 ITEM: EXPIRED BRAKE MAINTENANCE TAG (8.4.6.4.).
#39203379R
Nov 18, 2026
PENDING
$1,250
Aug 13, 2026Elevators CLASS - 1
FAILURE TO MAINTAIN DEVICE IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, THE ONLY DEVICE IN THE SECTION OF THE BUILDING IS FOUND TO BE OUT OF SERVICE, CREATING
#39200414J
Oct 28, 2026
PENDING
$1,250
Aug 13, 2026Construction CLASS - 1
FAILURE TO MAINTAIN OBSERVED ELEVATOR #1 MALFUNCTIONED TRAPPING RESPONDENT WHICH LEAD TO FDNY RESCUE INDIVIDUAL FROM ELEVATOR., REPAIR AND/REPLACE; MAKE REPAIRS AS PER CODE.
#39200585Y
Oct 28, 2026
PENDING
$2,500
Apr 8, 2025Local Law CLASS - 2
FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8C AND 9C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #913904. AGG1: PRIOR NOV 3702310
#37034479R
Jun 25, 2025
DEFAULT
$10,000
Apr 8, 2025Local Law CLASS - 2
FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8C AND 9C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #913902. AGG1: PRIOR NOV 3702319
#37034478P
Jun 25, 2025
DEFAULT
$10,000
Oct 19, 2022Local Law CLASS - 2
FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE8C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL&APPURTENANCES REQUIRED BY28-302.4 FOR CONTROL#813904.AGG1:PRIOR NOV37018188R UNDER28-302.4 SUB
#37023105Z
Apr 19, 2023
IN VIOLATION
$3,125
Oct 19, 2022Local Law CLASS - 2
FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE 8C REPORT OF CRITICAL EXAMINATOIN DOCUMENTING CONDITION OF EXTERIOR WALL & APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #813902.AGG1:PRIOR NOV 37018187P UNDER 28-30
#37023193H
Apr 19, 2023
IN VIOLATION
$3,125
Feb 13, 2020Local Law CLASS - 2
FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#813902. REMEDY:SUBMIT ACCEPTABLE REQUIR
#37018187P
Sep 25, 2020
IN VIOLATION
$1,250
Feb 13, 2020Local Law CLASS - 2
FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#813904. REMEDY:SUBMIT ACCEPTABLE REQUIR
#37018188R
Sep 25, 2020
IN VIOLATION
$1,250
DOB (2)
IssuedViolationStatus
Feb 22, 2024NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024
#01010
DOB VIOLATION - ACTIVE
Feb 22, 2024NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024
#01009
DOB VIOLATION - ACTIVE
DOB NOW Safety (7)
IssuedViolationStatus
Oct 14, 2026AEUHAZ FTC-AEU-HAZ
Active
Sep 25, 2026Benchmarking - LL84 DQ-EN-BENCH
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Active
Sep 16, 2026AEUHAZ FTC-AEU-HAZ
Active
Feb 22, 2024Facades FISPNRF
FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024
Active
Feb 22, 2024Facades FISPNRF
FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024
Active
Apr 30, 2019Facades FISPNRF
FAILED TO FILE FISP CYCLE 8C TECHNICAL REPORT BY 02/21/2019
Active
Apr 30, 2019Facades FISPNRF
FAILED TO FILE FISP CYCLE 8C TECHNICAL REPORT BY 02/21/2019
Active
HPD (23) · C 14 · B 8 · A 1
IssuedClassViolationCorrect by
Feb 10, 2026BApt 5H · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 5H, 5th STORY, 4th APARTMENT FROM SOUTH AT WESTMar 17, 2026
Jan 27, 2026BApt 4J · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ.FT AT EAST WALL IN THE BATHROOM LOCATED AT APT 4J, 4th STORY, 1st APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 18257436 ISSUED 27-SEP-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-201Mar 3, 2026
Jan 27, 2026BApt 4J · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ.FT AT NORTH WALL IN THE BATHROOM LOCATED AT APT 4J, 4th STORY, 1st APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 18257437 ISSUED 27-SEP-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-20Mar 3, 2026
Jan 21, 2026C§ 27-2056.4(H) AND 27-2056.17 ADM CODE -CORRECT FAILURE TO PROVIDE TO THE DEPARTMENT WITHIN 45 DAYS OF DEMAND ALL RECORDS REQUIRED TO BE MAINTAINED BY OWNER PURSUANT TO LOCAL LAW 1 OF 2004 RELATED TO LEAD-BASED PAINT NOTICES, INSPECTIONS AND REMEDIATION/ABATEMENT ACTIVITIES.Jan 25, 2026
Jan 21, 2026C§ 27-2056.4 ADM CODE- CORRECT FAILURE TO NOTIFY OCCUPANTS AND/OR TO INVESTIGATE LEAD-BASED PAINT HAZARDS.Jan 25, 2026
Sep 29, 2025BApt 4J · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 20 SQ.FT AT WEST WALL IN THE BATHROOM LOCATED AT APT 4J, 4th STORY, 1st APARTMENT FROM WEST AT NORTHNov 3, 2025
Sep 29, 2025AApt 4J · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE WEST WALL, 1st DOOR FRAME FROM EAST AT SOUTH WALL, EAST WALL IN THE FOYER LOCATED AT APT 4J, 4th STORY, 1st APARTMENT FROM WEST AT NORTHJan 2, 2026
Sep 29, 2025CApt 4J · § 27-2056.7, 27-2056.8, 27-2056.9 ADM CODE -CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY PERFORMING ACTIVITIES NECESSARY TO ABATE TESTED LEAD-BASED PAINT FROM REQUIRED WINDOW AND/OR DOOR FRICTION SURFACES FOR APARTMENT AND MAKE FLOORS SMOOTH AOct 23, 2025
Nov 15, 2019CApt 6H · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6H, 6th STORY, 4th APARTMENT FROM SOUTH AT WESTDec 6, 2019
Sep 24, 2009BApt 5A · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE ( MS ESPINOZA) IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 5th STORYOct 29, 2009
Sep 24, 2009BApt 5A · § 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE AND ROACHES THRUOUT IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 5th STORYOct 29, 2009
Sep 24, 2009BApt 5A · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR INOPERATIVE / MS ESPINOZA INNA / IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 5th STORY, 2nd APARTMENT FROM NORTH AT EASTOct 29, 2009
Sep 24, 2009BApt 2D · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE WALLS AND CEILING IN THE ENTIRE APARTMENT LOCATED AT APT 2D, 2nd STORY, APARTMENT AT SOUTHOct 29, 2009
Sep 24, 2009C§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE UPPER SASH WINDOWS KITCHEN 6 STY 2ND EAST APT FROM SOUTH 6B ER1.Sep 30, 2009
Sep 24, 2009C§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS & CEILINGS THRU OUT 6 STY 2ND EAST APT FROM SOUTH 6B.Sep 30, 2009
Sep 24, 2009C§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER 6 STY 2ND EAST APT FROM SOUTH 6B ER1.Sep 30, 2009
Oct 16, 2000CApt 5A · § 27-2056.5 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR IS ON A DETERIORATED SUBSURFACE - USING EXCLUSIVE INTERIM CONTROLS. NORTH WALL AT TOP IN THE FOYER LOCATED AT APT 5A, 5th STORY, 2nd APARTMENT FROM NORTH AT EASTNov 16, 2000
Oct 16, 2000CApt 5A · § 27-2056.5 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR IS ON A DETERIORATED SUBSURFACE - USING EXCLUSIVE INTERIM CONTROLS. NORTH RISER AT CENTER IN THE BATHROOM LOCATED AT APT 5A, 5th STORY, 2nd APARTMENT FROM NORTH AT EASTNov 16, 2000
Oct 16, 2000CApt 5A · § 27-2056.5 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR IS ON A DETERIORATED SUBSURFACE - USING EXCLUSIVE INTERIM CONTROLS. SOUTH WALL AT TOP IN THE FOYER LOCATED AT APT 5A, 5th STORY, 2nd APARTMENT FROM NORTH AT EASTNov 16, 2000
Oct 16, 2000CApt 5A · § 27-2056.5 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR IS ON A DETERIORATED SUBSURFACE - USING EXCLUSIVE INTERIM CONTROLS. WEST WALL AT TOP IN THE KITCHEN LOCATED AT APT 5A, 5th STORY, 2nd APARTMENT FROM NORTH AT EASTNov 16, 2000
Oct 16, 2000CApt 5A · § 27-2056.5 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR IS ON A DETERIORATED SUBSURFACE - USING EXCLUSIVE INTERIM CONTROLS. EAST WALL AT TOP IN THE 1st ROOM FROM EAST LOCATED AT APT 5A, 5th STORY, 2nd APARTMENT FROM NORTH AT EASTNov 16, 2000
Oct 2, 2000CApt 5A · § 27-2056.5 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR IS ON A DETERIORATED SUBSURFACE - USING EXCLUSIVE INTERIM CONTROLS. NORTH WALL AT TOP IN THE 1st PRIVATE HALLWAY FROM NORTH LOCATED AT APT 5A, 5th STORYNov 2, 2000
Oct 2, 2000CApt 5A · § 27-2056.5 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR IS ON A DETERIORATED SUBSURFACE - USING EXCLUSIVE INTERIM CONTROLS. WEST WALL AT CENTER IN THE KITCHEN LOCATED AT APT 5A, 5th STORYNov 2, 2000

Issued in the last 120 days

DateSourceWhatNow
Oct 14, 2026DOB SafetyAEUHAZ: Open
Sep 25, 2026DOB SafetyBenchmarking - LL84: FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4Open
Sep 16, 2026DOB SafetyAEUHAZ: Open
Sep 8, 2026ECBElevators: CEASE USE ITEM: INOPERATIVE ZONE LOCK RESTRICTOR (2.14.5.7.1.). CLASS 2 ITEM: EXPIRED BRAKE MAINTENANCE TAG (8.4.6.4.).Open
Aug 13, 2026ECBElevators: FAILURE TO MAINTAIN DEVICE IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, THE ONLY DEVICE IN THE SECTION OF THE BUILDING IS FOUND TO BE OUT OF SERVICE, CREATINGOpen
Aug 13, 2026ECBConstruction: FAILURE TO MAINTAIN OBSERVED ELEVATOR #1 MALFUNCTIONED TRAPPING RESPONDENT WHICH LEAD TO FDNY RESCUE INDIVIDUAL FROM ELEVATOR., REPAIR AND/REPLACE; MAKE REPAIRS AS PER CODE.Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 3, 2026, 8:32 AM ET. BBL 3072320081.

Look up another building