3 floors · 6 apartments · 6,000 sq ft · built 1931 · class C2 · owner of record: Camella Joseph
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 9 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 50 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 50 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 50 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 66 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-10 (Accepted). Agency page | On file | 2026 reports accepted |
None open.
| Issued | Violation | Status |
|---|---|---|
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION #29390 | DOB VIOLATION - ACTIVE |
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION #07817 | DOB VIOLATION - ACTIVE |
| Apr 25, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION #10263 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Apr 25, 2023 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2022 INSPECTION REPORT | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jul 2, 2025 | C | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER SASH WINDOW AT PUBLIC HALL STAIRS, 1st STORY | Jul 8, 2025 |
| May 15, 2025 | C | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING HOOK AND EYE AT BULKHEAD DOOR AT PUBLIC HALL, 3rd STORY | May 29, 2025 |
| Apr 21, 2023 | C | Apt 2 · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) NORTH WALL, SOUTH WALL IN THE FOYER LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SO | May 15, 2023 |
| Apr 21, 2023 | C | Apt 2 · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) SOUTH WALL, 1st WINDOW FRAME FROM NORTH AT EAST WALL IN THE 2nd ROOM FROM EAST AT NORT | May 15, 2023 |
| Apr 21, 2023 | A | Apt 2 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE 2nd ROOM FROM EAST AT SOUTH, THE BATHROOM , THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 25, 2023 |
| Apr 21, 2023 | B | Apt 2 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BASE CABINET AND COUNTER TOP AT SINK IN THE KITCHEN LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | May 26, 2023 |
| Apr 21, 2023 | B | Apt 2 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE UPPER WALL CABINET AT EAST WALL IN THE KITCHEN LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | May 26, 2023 |
| Apr 21, 2023 | B | Apt 2 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE UPPER WALL CABINET AT NORTH WALL IN THE KITCHEN LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | May 26, 2023 |
| Apr 21, 2023 | B | Apt 2 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BASE CABINET AT WASH BASIN IN THE BATHROOM LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | May 26, 2023 |
| Apr 21, 2023 | B | Apt 2 · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT THE WASH BASIN IN THE BATHROOM LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | May 26, 2023 |
| Apr 21, 2023 | B | Apt 2 · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT THE BATHTUB IN THE BATHROOM LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | May 26, 2023 |
| Apr 21, 2023 | B | Apt 2 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | May 26, 2023 |
| Apr 21, 2023 | B | Apt 2 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | May 26, 2023 |
| Apr 21, 2023 | B | Apt 2 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT SOUTH WALL IN THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | May 26, 2023 |
| Apr 21, 2023 | B | Apt 2 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | May 26, 2023 |
| Apr 21, 2023 | B | Apt 2 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | May 26, 2023 |
| Apr 21, 2023 | C | Apt 2 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | May 17, 2023 |
| Apr 21, 2023 | C | Apt 2 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | May 17, 2023 |
| Apr 21, 2023 | B | Apt 2 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | May 26, 2023 |
| Apr 21, 2023 | B | Apt 2 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE WEST WALL IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | May 26, 2023 |
| Apr 21, 2023 | B | Apt 2 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE SOUTH WALL IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | May 26, 2023 |
| Apr 21, 2023 | B | Apt 2 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | May 26, 2023 |
| Apr 21, 2023 | B | Apt 2 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE WEST WALL IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | May 26, 2023 |
| Apr 21, 2023 | B | Apt 2 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | May 26, 2023 |
| Apr 21, 2023 | B | Apt 2 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | May 26, 2023 |
| Apr 21, 2023 | B | Apt 2 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE WEST WALL IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | May 26, 2023 |
| Apr 21, 2023 | B | Apt 2 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE SOUTH WALL IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | May 26, 2023 |
| Apr 21, 2023 | B | Apt 2 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE EAST WALL IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | May 26, 2023 |
| Apr 21, 2023 | B | Apt 2 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | May 26, 2023 |
| Apr 21, 2023 | B | Apt 2 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | May 26, 2023 |
| Apr 21, 2023 | B | Apt 2 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE BATHROOM LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | May 26, 2023 |
| Apr 21, 2023 | B | Apt 2 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | May 26, 2023 |
| Apr 21, 2023 | A | Apt 2 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE 1st WINDOW FRAME FROM SOUTH AT WEST WALL IN THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 25, 2023 |
| Apr 21, 2023 | B | Apt 2 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | May 26, 2023 |
| Apr 21, 2023 | C | Apt 2 · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) BASEBOARD AT SOUTH WALL IN THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT 2, 1st STORY | May 15, 2023 |
| Dec 1, 2022 | A | Apt 2 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE BATHROOM , THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Mar 6, 2023 |
| Dec 1, 2022 | B | Apt 2 · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASH BASIN IN THE BATHROOM LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 5, 2023 |
| Dec 1, 2022 | C | Apt 2 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Dec 27, 2022 |
| Dec 1, 2022 | B | Apt 2 · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SHOWER IN THE BATHROOM LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 5, 2023 |
| Dec 1, 2022 | B | Apt 2 · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 5, 2023 |
| Dec 1, 2022 | C | Apt 2 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Dec 27, 2022 |
| Dec 1, 2022 | B | Apt 2 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 5, 2023 |
| Dec 1, 2022 | B | Apt 2 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING, NORTH WALL, SOUTH WALL, EAST WALL, WEST WALL IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 5, 2023 |
| Dec 1, 2022 | B | Apt 2 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING, NORTH WALL, SOUTH WALL IN THE BATHROOM LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 5, 2023 |
| Dec 1, 2022 | B | Apt 2 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 5, 2023 |
| Dec 1, 2022 | B | Apt 2 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING, SOUTH WALL IN THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 5, 2023 |
| Dec 1, 2022 | B | Apt 2 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL, EAST WALL IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 5, 2023 |
| Dec 1, 2022 | B | Apt 2 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 5, 2023 |
| Dec 1, 2022 | A | Apt 2 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE KITCHEN , THE 2nd ROOM FROM EAST AT NORTH, THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Mar 6, 2023 |
| Dec 21, 2018 | B | Apt 2 · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 25, 2019 |
| Dec 21, 2018 | B | Apt 2 · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF WOOD PANELING AT EAST WALL BEHIND THE GAS RANGE IN THE KITCHEN LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 25, 2019 |
| Dec 21, 2018 | B | Apt 2 · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE HINGES AT THE DOOR IN THE ENTRANCE LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 25, 2019 |
| Dec 21, 2018 | B | Apt 2 · § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS IN THE ENTRANCE LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 25, 2019 |
| Dec 21, 2018 | A | Apt 2 · § 27-2005 ADM CODE REFIT DOOR IN THE ENTRANCE LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Mar 26, 2019 |
| Dec 21, 2018 | B | Apt 2 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CONCRETE FLOOR IN THE BATHROOM LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 25, 2019 |
| Dec 21, 2018 | B | Apt 2 · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 25, 2019 |
| Dec 21, 2018 | B | Apt 2 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 25, 2019 |
| Dec 21, 2018 | B | Apt 2 · § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM AT LEAST 1 WINDOW OR PROVIDE APPROVED TYPE GATE , IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 25, 2019 |
| Dec 21, 2018 | B | Apt 2 · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 25, 2019 |
| Dec 21, 2018 | B | Apt 2 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 25, 2019 |
Showing 60 of 118. Full list on the agency site.