2 floors · 45,060 sq ft · built 1935 · class W1 · owner of record: Nyc Department Of Education
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 45 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 45 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 45,060 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 166 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 166 days | Annual filing |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-10 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Mar 20, 2026 | Construction CLASS - 2 REISSUE ON ECB #35717106Y. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT EXIT 10 AND EXIT 12 AT KITCHEN EXIT TOP OF RETAINING WALL FENCE LOOSE NEEDS WELDING OR A FORM ATTACHMENT WITH COUPLING #35727261N | May 8, 2026 POP/IN-VIO | $0 |
| Mar 20, 2026 | Construction CLASS - 2 REISSUE ON ECB #35717107X. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: FIRE RATED AND SMOKE DOORS NOT CLOSING PROPERLY DUETO MISSING HARDWARE OR FAULTY HARDWARE OR BINDING ON CLASSROOMS, 201, #35727260L | May 8, 2026 POP/IN-VIO | $0 |
| Mar 20, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1; 27-381. NOTED: EXIT DISCHARGE ILLUMINATION NOT FUNCTIONING WHEN TESTED ON BOX 1 #35727262P | Apr 10, 2026 POP/IN-VIO | $0 |
| Apr 9, 2025 | Construction CLASS - 2 REISSUE#35678796L DATE OF ISSUE:04.22.2025 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.AT THE TIME OF INSPECTION OBSERVED & NOTED THAT AT 2ND FLOOR INTERIOR SELF CLOSING DOORS ARE NOT CLOSING PROPERLY #35717107X | Jul 18, 2025 POP/IN-VIO | $0 |
| Apr 9, 2025 | Construction CLASS - 2 REISSUE#35678799R DATE OF ISSUE:04.22.2024 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.AT EXIT#12 KITCHEN EXIT AT TOP OF RETAININGWALL,THE FENCE IS IN DISREPAIR DUE TO LOSE FROM WELDED JOINTS.REM:REPA #35717106Y | Jul 18, 2025 POP/IN-VIO | $0 |
| Apr 22, 2024 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: OBSERVEDAT EXP. #2, FENCE ON TOP OF THE RETAINING WALL BY EXIT #12/KITCHEN EXIT. THE FENCE IS IN DISREPAIR DUE TO BEING LOSE FROM WELDED JOINTS, CRE #35678799R | Jun 21, 2024 POP/IN-VIO | $0 |
| Apr 22, 2024 | Construction CLASS - 2 RE-ISSUE #35672753Y-FAILURE TO MAINTAIN IN CODE-COMPLIANT MANNER. NOTED: OBSERVED INTERIOR SELF-CLOSING DOORS LOCATED AT 2 FLR.-ST. 'E', ROOMS #201, #202, #205, #206, #211, #212, #214, #215, #222, #223, #221, # #35678796L | Jun 21, 2024 POP/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #07530 | DOB VIOLATION - ACTIVE |
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #07531 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device | Active |
None open.