2 floors · 2 apartments · 4,600 sq ft · built 1931 · class S2 · owner of record: Nycpi2 Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 56 days | Keep the report on file (not filed with DOB) |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2019-11-06 (Accepted). Agency page | Dec 31, 2026 in 56 days | 1 of 1 without an accepted 2026 report yet |
| Annual property registration Check HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 300 days | Registered through 2027-09-01 |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1152 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 3, 2022 | Site Safety CLASS - 1 3 STORY ALT,ACTIVE JOBSITE,4 WORKERS ON SITE,UPON REQUEST TO SEE CONSTR.DAILY LOG BOOK,LOG BOOK MISING CS SIGNATURE ,NO RECORD OF HIS VISIT OVER 2 MONTH,TIME CS ARRIVED AD WHAT TIME HE LEAVE,NO DESIGNATED COMP. #39507103Z | Nov 22, 2022 IN VIOLATION | $625 |
| May 19, 2022 | Construction CLASS - 1 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS AT TIME OF INSPECTION OF 3 STORY BUILDING UNDER ALTERATION OBSERVED NEW FLOOR JOISTS(C-JOISTS)AT 1ST,3RD FLOORS & ROOF WITH BL #35652340H | Jan 19, 2023 IN VIOLATION | $625 |
| May 19, 2022 | Construction CLASS - 1 BC3314.1 FAILURE TO MAINTAIN SUPPORTED SCAFFOLD IN CODE COMPLIANCE AT TIME OF INSPECTION OF 3 STORY BUILDING UNDER ALTERATION OBSERVED SUPPORTED SCAFFOLD AT EXP #1 #4 MISSING TIE INS AT TOP FRAME (ONLY 1 PROVID #35652341J | Jan 19, 2023 IN VIOLATION | $625 |
| Oct 4, 2021 | Construction CLASS - 1 BC3314 SUPPORTED SCAFFOLD NOT MAINTAINED AS PER CODE. AT TIME OF INSPECTION OBSERVED SUPPORTED SCAFFOLD AT EXP #3 NO GUARD RAILS AND PLATFORM NOT DECKED PER CODE.STOP ALL WORK ON SS AT EXP #3.MAKE S CODE COMPLI #35589414M | Jul 26, 2022 IN VIOLATION | $2,500 |
| Oct 4, 2021 | Construction CLASS - 1 3309.10 ROOF PROTECTION.AT TIME OF INSPECTION OBSERVED JOB SITE STRUCTURE ABOVE ADJOINING PROPERTY AT EXP #2 PLANS AND ADJOINING PROPERTY ROOFS PROTECTION DID NOT CONFORM TO SSP OR CODE DID NOT COVER REQUIRED A #35589413K | Jul 26, 2022 IN VIOLATION | $2,500 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 5, 2026, 10:03 PM ET. BBL 4034350029.