| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 64 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 56,643 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 185 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 185 days | Annual filing |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 10 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 795 days | Next cycle year 2028 |
| Energy audit and retro-commissioning (2034) Likely applies Local Law 87 · Calendar year 2034 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1594). Agency page | Dec 31, 2034 in 2986 days | Next due 2034 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-30 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jan 7, 2026 | Construction CLASS - 2 3307.6.5.1AT TIME OF INSPECTION OF A 6 STORIES APARTMENT BUILDING I OBSERVED ABANDONMENT OF INSTALLATION OF SIDEWALK SHED AT EXPOSURE # 1, I OBSERVED MISSING PARAPET, JUNIOR BEAMS AND CORRUGATED SHEETS ON THE S #39548870K | Oct 6, 2026 IN VIOLATION | $2,400 |
| Dec 15, 2025 | Construction CLASS - 2 OBSERVED IN BASEMENT INSTALLED THREE GAS BYPASS ALL WORK COMPLETED 100 PERCENT NO PERMITS, OBTAIN ALL PERMITS #39170458R | Oct 29, 2026 PENDING | $1,250 |
| Dec 15, 2025 | Construction CLASS - 2 OBSERVED DAMAGED SPRINKLER HEADS ON THE 6TH FLOOR. THROUGHOUT THE BUILDING USING FENCO COUPLINGS ON WASTE LINES AND NOT HAVING OPEN ENDED TOILET SEATS IN BATHROOMS. BASEMENT SPRINKLER HEAD INSTALLED BACKWARDS A #39170459Z | Oct 29, 2026 PENDING | $1,250 |
| Mar 10, 2025 | Construction CLASS - 2 AT TIME OF INSPECTION OF 6 STORY BUILDING I OBSERVED SIDEWALK SHED IN PLACE WITH LIGHTING NOT IN OPERATING CONDITIONS CAUSING HAZARDOUS CONDITIONS.PROVIDE LIGHTING AS REQUIRED #39537790R | Jun 12, 2025 IN VIOLATION | $2,400 |
| Jun 10, 2024 | Unknown CLASS - 2 I OBSERVED THE NEW ELECTRICAL GROUND CONDUCTOR INSTALLED ON THE WATER MAIN BEYOND THE WATER METER, THE GATE VALVE AND FLANGE FITTINGS, THIS DOES NOT COMPLY WITH THE EGC BEING INSTALLED WITH THE LEAST RESISTANT #39116389P | Nov 14, 2024 IN VIOLATION | $2,400 |
| Jun 10, 2024 | Unknown CLASS - 1 I OBSERVED IN THE BASEMENT AREA THE IMPROPER INSTALLATION OF THE LINE AND LOAD CONDUCTORS IN AN UNLABELED 200 AMP 3 PHASE DISCONNECT SWITCH IN THE BASEMENT ELECTRICAL METER ROOM, THE CONDUCTORS ARE INSTALLED TH #39116395L | Apr 10, 2025 IN VIOLATION | $1,600 |
| Dec 19, 2023 | Construction CLASS - 1 UNLAW ACTS: FAILURE TO COMPLY WITH COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION# 39076743P ISSUED ON 12/30/2022 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01., COMPLY WITH #39101800Y | Jan 13, 2026 IN VIOLATION | $1,250 |
| Dec 19, 2023 | Construction CLASS - 1 UNLAW ACTS: FAILURE TO COMPLY WITH COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION# 39076744R ISSUED ON 12/30/2022 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01., COMPLY WITH #39101795Z | Dec 15, 2026 DEFAULT | $6,250 |
| Dec 19, 2023 | Construction CLASS - 1 UNLAW ACTS: FAILURE TO COMPLY WITH COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION# 39076742N ISSUED ON 12/30/22 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01., COMPLY WITH CO #39101798Y | Dec 15, 2026 DEFAULT | $6,250 |
| Dec 30, 2022 | Unknown CLASS - 1 I OBSERVED ON THE ROOFTOP LEVEL THE UNPERMITTED USE OF FLEXIBLE CORDS TO SUPPLY POWER TO THE EXTERIOR SPLIT A.C. CONDENSOR UNIT, AS PER EC 400.8. ALSO NOTED THE UNPERMITTED USE OF LFMC IN LENGTHS LONGER THAN 6F #39076743P | Sep 11, 2025 IN VIOLATION | $400 |
| Dec 30, 2022 | Unknown CLASS - 2 I OBSERVED IN THROUGHOUT THE BUILDING HALLWAYS ABOVE THE EXIT DOORS JUNCTION BOXES MADE INACCESSIBLE BY THE STRUCTURE OF THE BUILDING WALLS AND CEILINGS., PROVIDE/MAINTAIN ACCESS/WORK SPACE; PROVIDE AND MAINTAI #39076745Z | Apr 20, 2023 IN VIOLATION | $500 |
| Dec 30, 2022 | Unknown CLASS - 1 I OBSERVED IN THE BASEMENT WATER METER ROOM FAILURE TO PROPERLY INSTALL GROUND CONDUCTOR TO WATER PIPE, I NOTED THE GROUND WIRE DISCONNECTED FROM THE WATER MAIN AND NOT INSTALLED ACROSS THE WATER METER AS REQUI #39076742N | Sep 11, 2025 IN VIOLATION | $1,200 |
| Dec 30, 2022 | Unknown CLASS - 1 I OBSERVED IN THE BASEMENT AN UNLABELED NEWLY INSTALLED 200 AMP 3PHASE DISCONNECT SWITCH IMPROPERLY WIRED WITH LINE SIDE CONDUCTORS INSTALLED ON THE FUSE SIDE OF THE SWITCH. THIS ALLOWS FOR THE FUSES TO REMAIN #39076744R | Sep 11, 2025 IN VIOLATION | $1,200 |
| Jul 20, 2020 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: TERRACOTTA LOCATED BELOW 2ND FL WINDOW IS CRACKED,BROKEN FALLEN PATCHED W/CEMENT OR SAME LOCATION. REMEDY: REPAIR OR REPLACE. #35502651L | Jul 15, 2021 IN VIOLATION | $625 |
| Nov 8, 2019 | Construction CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER ORDER CONTAINED IN SUMMONS/VIOLAT ON#39009944L ISSUED ON 09-23-2019 AND TO FIEL A CERTIFICATE OF CORREC ION PURSUANT TO 28-201.1 AND 1RCNY 102-01.FILED A CERTIFICATE OF CORRE #35512223Y | Mar 4, 2021 IN VIOLATION | $625 |
| Aug 22, 2017 | Construction CLASS - 1 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDINGS DEPARTMENT RECORDS.CERTIFICATE OF OCCUPANCY #29407 INDICATESBUILDING AS 6 STORIES WITH 51 SROS AND ONE CLASS A APARTMENT AT CELLAR #35297140J | Sep 6, 2018 IN VIOLATION | $0 |
| Jul 20, 2016 | Construction CLASS - 2 OCCUPANCY CONTRARY TO C OF O. NOTED: C OF O #29407 STATES 36 SRO'S ON FLOORS 2 THRU 6 & 4 KITCHENS ON EACH FLOOR. OBSERVED 38 SRO'S ON FLOORS 2 THRU 6 & 2 KITCHENS ON EACH FLOOR IN PREVIOUSLY NOTED IN ECB #3517 #35200985H | Oct 13, 2016 IN VIOLATION | $0 |
| Feb 29, 2016 | Construction CLASS - 2 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICAE OF OCCUPANCY OR BUILDING DEPT RECORDS. COFO #29407 INDICATES (CELLAR) 1-APT AND HEAT ING; (1ST FLR) 1 APT, 15 SINGLE ROOM OCCUPANCY (1-COMMUNITY KITCHEN, 1 #35171574N | Oct 13, 2016 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION #40558 | DOB VIOLATION - ACTIVE |
| Nov 16, 1999 | PLUMBING #110HB1 | VIOLATION WORK WITHOUT PERMIT - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)