3 floors · 2 apartments · 4,262 sq ft · built 1950 · class S2 · owner of record: Bautista Catalina B
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 58 days | Keep the report on file (not filed with DOB) |
| Annual property registration Check HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 302 days | Required only if the owner doesn't live there |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1154 days | Next cycle year 2029 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-20 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jan 4, 2017 | Boilers CLASS - 2 6A,15,24B,32A,34B,38,60,60A,50B,50C,50D,50E. 50-UNUSED,UNCAPPED WATERPIPE ABOVE BOILER; 50A-STORAGE AT BAS METERS; 50B-CEILING OPEN ABOVE GAS METERS; 50C-FLUES INCORRECTLY SUPPORTED; 50D-HOT WATER HEATER SAFET #32086775Y | Feb 21, 2017 STIPULATION/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Feb 10, 1997 | LOCAL LAW 62/91 - BOILERS #33755 | DOB VIOLATION - ACTIVE |
| Jun 7, 1994 | LOCAL LAW 62/91 - BOILERS #02829 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Feb 10, 1997 | Boiler LL6291 | Active |
| Jun 7, 1994 | Boiler LL6291 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Aug 13, 2008 | B | SECTION 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRICAL WIRING WALLS & CEILINGS ALL STY. PUBLIC HALL. | Sep 17, 2008 |
| Aug 13, 2008 | B | SECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR WALLS AND CEILINGS ALL STYS. PUBLIC HALL . | Sep 17, 2008 |
| Aug 13, 2008 | B | SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING DOOR KNOB ASSEMBLY ENTRANCE DOOR TO BLDG. | Sep 17, 2008 |
| Aug 13, 2008 | B | SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING CERAMIC WALL TILE BATHROOM 2 STY. APT. | Sep 17, 2008 |
| Aug 13, 2008 | B | SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF VERMIN ROACHES THROUGHOUT 2 STY. APT. | Sep 17, 2008 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 3, 2026, 4:11 PM ET. BBL 4026400011.