2 floors · 4 apartments · 2,340 sq ft · built 1920 · class C3 · owner of record: 543 E 52 Group Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 45 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 45 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 61 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 17 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 410 days | Next cycle year 2027 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 9, 2026 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPT. OF BUILDINGS FOR VIOLATION #39177313H., FILE A CERTIFICATE OF CORRECTION #39203495Y | Nov 18, 2026 PENDING | $1,250 |
| Sep 9, 2026 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPT. OF BUILDINGS FOR VIOLATION #39182445X., FILE A CERTIFICATE OF CORRECTION #39203494M | Nov 18, 2026 PENDING | $1,250 |
| Mar 30, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. VIO#39143879L ,IS STILL IN A STATE OF DISREPAIR LARGE CRACKS AT EPP#3&4 NO FRONT WALL AND PART OF EXP#4 WALL IS MISSING.AT REAR ONE STORY BRICK AND BLOCK G #39182445X | Jun 3, 2026 DEFAULT | $25,000 |
| Feb 13, 2026 | Construction CLASS - 1 FAILURE TO OBEY A VACATE ORDER FROM THE COMMISSIONER PER 28-207.4: AT THE TIME OF INSPECTION, OBSERVED CELLAR OCCUPIED AS A CLASS A APARTMENT ( FEMALE PRESENT) WHILE UNDER VACATE ORDER WITH HAZARDOUS CONDITION #39177313H | Apr 22, 2026 DEFAULT | $25,000 |
| Feb 13, 2026 | Unknown CLASS - 2 RESIDENCE CONVERTED MAINTAINED OR OCCUPIED AS A DWELLING FOR MORE THAN LEGALLY APPROVED: AT THE TIME OF INSPECTION, OBSERVED CELLAR LEVEL ALTERED AND OCCUPIED (FEMALE PRESENT) AS A CLASS A DWELLING WITH BEDROOM #39177303Y | Apr 22, 2026 DEFAULT | $10,000 |
| Feb 13, 2026 | Construction CLASS - 2 WWOP: AT THE TIME OF INSPECTION, OBSERVED AT CELLAR LEVEL, CLASS A APARTMENT CREATED WITH 3 PC BATHROOM, RESIDENTIAL SINK AND GAS STOVE. DOB RECORDS INDICATE NO PERMIT ON FILE FOR PLUMBING WORK DONE FOR GAS PIP #39177301K | Apr 22, 2026 DEFAULT | $6,250 |
| Feb 13, 2026 | Construction CLASS - 2 WWOP: AT THE TIME OF INSPECTION, OBSERVED AT CELLAR LEVEL, INSTALLATION OF ELECTRICAL WIRING SUPPLYING THE CLASS A APARTMENT CREATED, INCLUDING LIGHT FIXTURES, REFRIGERATOR, PORTABLE AIR CONDITIONER AND MICROWA #39177304X | Apr 22, 2026 DEFAULT | $6,250 |
| Feb 13, 2026 | Construction CLASS - 2 WWOP: AT THE TIME OF INSPECTION, OBSERVED AT CELLAR LEVEL, FULL HEIGH PARTITION WALLS INSTALLED TO CREATE CLASS A APARTMENT CONSISTING OF BEDROOM, LIVING-ROOM, 3 PC BATHROOM, KITCHEN EQUIPPED WITH REFRIGERATOR, #39177302M | Apr 22, 2026 DEFAULT | $6,250 |
| Apr 2, 2025 | Construction CLASS - 1 AT TIME OF INSPECTION, OBSERVED DETACHED 1 STORY BRICK GARAGE AT THE REAR OF THE PROPERTY IN A STATE OF DISREPAIR, EXPOSURE 3 & 4 C.M.U. WALL VERTICAL CRACK EXTENDING FROM GRADE TO THE CEILING PLATE, MISSING FR #39143879L | Jun 11, 2025 DEFAULT | $12,500 |
| Feb 27, 2010 | Construction CLASS - 1 WORK WITHOUT A PERMIT CELLAR CONVERTED W/O ANY PERMITS TO CLASS AAPT WITH FULL KITCHEN FULL BATHROOM BEDROOM LIVING RM ALL PLUMBING ELECTRICAL & PARTITION WORK DONE W/O ANY PERMITS OR APPROVALS. REMEDY OBTAIN #34829153R | May 10, 2010 WRITTEN OFF | $0 |
| Feb 27, 2010 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN A CODE COMPLAINT MANNER PLASTER CEILING ATRADIATOR LEGALIZE CELLAR DOWN TO 1ST FLOOR SAVES AT 2 FLOOR BALCONY NOT MAINTAINED WOOD & VINYL SIDING MISSING BAVES EXPOSED TO WEATHER ELE #34829151N | May 10, 2010 WRITTEN OFF | $0 |
| Feb 27, 2010 | Construction CLASS - 1 RESIDENCE ALTERED FOR OCCUPANCY AS A DWELLING FROM 1/2 FAMILIES TO 4 0R MORE FAMILIES ONE FAMILY WOOD FRAMED DWELLING OCCUPIED AS 4 FAMILY DWELLING 3 S.R.O WITH COMMON BATHROOM AT 2 FLR CELLAR CONVERTED W/O PER #34829152P | May 24, 2010 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Feb 27, 2010 | CONSTRUCTION WORK W/OUT PERMIT #ERTZ03 | VIOLATION WORK WITHOUT PERMIT - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jan 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle D (premises is in Community District 17) | Active |
| Jan 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle D (premises is in Community District 17) | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Sep 25, 2024 | B | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED WIRING NEAR BUILDING ENTRANCE DOOR , 1st STORY | Oct 30, 2024 |
| Mar 1, 2010 | B | Apt 2 · SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER WINDOW SASH IN THE 3rd ROOM FROM EAST LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Apr 5, 2010 |
| Mar 1, 2010 | C | Apt 2 · SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE RADIATOR CONNECTION IN THE 3rd ROOM FROM EAST LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Mar 7, 2010 |
| Mar 1, 2010 | B | Apt 2 · SECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Apr 5, 2010 |
| Mar 1, 2010 | B | Apt 2 · SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE FLOOR IN THE BATHROOM LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Apr 5, 2010 |
| Mar 1, 2010 | B | Apt 2 · SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER WINDOW SASH IN THE BATHROOM LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Apr 5, 2010 |
| Mar 1, 2010 | B | Apt 2 · SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Apr 5, 2010 |
| Mar 1, 2010 | C | SECTION 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF UNCAPPED RADIATOR PIPE AT 1ST STORY PUBLIC HALL VESTIBULE | Mar 7, 2010 |
| Date | Source | What | Now |
|---|---|---|---|
| Sep 9, 2026 | ECB | Construction: FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPT. OF BUILDINGS FOR VIOLATION #39177313H., FILE A CERTIFICATE OF CORRECTION | Open |
| Sep 9, 2026 | ECB | Construction: FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPT. OF BUILDINGS FOR VIOLATION #39182445X., FILE A CERTIFICATE OF CORRECTION | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)