Brooklyn · Block 821 · Lot 7501 · 11220

5418 3 Avenue

5 floors · 18 apartments · 13,553 sq ft · built 2012 · class R4 · owner of record: Unavailable Owner

16open violations
$3,125ECB/OATH penalties owed
4HPD class C (immediately hazardous)
65dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 65 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 65 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 81 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 309 days
Registered through 2027-09-01
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1161 days
Next cycle year 2029

Open violations

ECB / OATH (1) · $3,125 owed
IssuedViolationHearingBalance
Jul 14, 2020Elevators CLASS - 1
PROVIDE DOOR LOCK MONITORING CODE DATA PLATE ON CONTROLLER., REPAIR PIT LIGHT., REMOVE WATER FROM PIT., CEASE USE ITEMS: REPAIR CAR DOOR SAFETY EDGE., DOOR ZONE RESTRICTOR HAS BEEN TAMPERED WITH/ DISABLED AND R
#39025397L
Nov 18, 2020
DEFAULT
$3,125
DOB (0)

None open.

DOB NOW Safety (8)
IssuedViolationStatus
Oct 10, 2025Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction
Active
Sep 18, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle B (premises is in Community District 7)
Active
Oct 11, 2024Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction
Active
Oct 11, 2024Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction
Active
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
Oct 14, 2020AEUHAZ FTC-AEU-HAZ
Active
HPD (8) · C 4 · B 2 · A 2
IssuedClassViolationCorrect by
Nov 19, 2018CApt 2D · § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT WASHBASIN IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM NORTH AT EASTNov 27, 2018
Nov 19, 2018AApt 2D · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE FLOOR AT WALKING AREA IN THE KITCHEN LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM NORTH AT EASTFeb 22, 2019
Nov 19, 2018CApt 2D · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WASHBASIN IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM NORTH AT EASTNov 27, 2018
Nov 19, 2018AApt 2D · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE WALL AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM NORTH AT EASTFeb 22, 2019
Oct 2, 2017BApt 4C · § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES ... IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 5th STORY, 1st APARTMENT FROM EAST AT SOUTHNov 6, 2017
Oct 2, 2017CApt 4C · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 3; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 5th STORY, 1st APAOct 30, 2017
Sep 29, 2017B§ 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION .. AT PUBLIC HALL, 4th STORYNov 3, 2017
Sep 7, 2017CApt 4C · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 3; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE KITCHEN LOCATED AT APT 4C, 3rd STORY, 1st APARTMENT FROct 5, 2017

Check the agency records