Brooklyn · Block 4034 · Lot 25 · 11208

540 Linwood Street

3 floors · 5 apartments · 2,902 sq ft · built 1930 · class C2 · owner of record: Sb & Ds Holdings Llc

36open violations
$0ECB/OATH penalties owed
5HPD class C (immediately hazardous)
47dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 47 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 63 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 291 days
Registered through 2027-09-01
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1143 days
Next cycle year 2029

Open violations

ECB / OATH (0)

None open.

DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (36) · C 5 · B 24 · A 7
IssuedClassViolationCorrect by
Sep 22, 2026B§ 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE AT BUILDING FRONT YARDOct 27, 2026
Sep 22, 2026B§ 27-2005 ADM CODE PROPERLY SECURE THE LOOSE HANDRAIL AT PUBLIC HALL STAIRS, 1st STORYOct 27, 2026
Sep 22, 2026B§ 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE BUILDING FRONT YARDOct 27, 2026
Sep 21, 2026B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE HANDRAIL AT 3RD STORY PUBLIC HALL AT PUBLIC HALL STAIRS, 3rd STORYOct 26, 2026
Aug 6, 2026CApt 1B · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MORE THAN 10 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 18812730 ISSUED 25-APR-26 HAS BEEN UPGRADED TO CLASS C PER ADMINISTRATIVE CODE 27-2017.Sep 1, 2026
Jun 29, 2026BApt 5 · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK ABOVE CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 5, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTAug 3, 2026
Jun 29, 2026A§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AT PUBLIC HALL, 3rd STORYOct 2, 2026
Jun 29, 2026B§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES TREE BRANCES AT EAST AT BUILDING FRONT AT FIRE ESCAPE, 2nd STORYAug 3, 2026
Jun 29, 2026A§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 3rd STORYOct 2, 2026
Jun 29, 2026BApt 5 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 5, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTAug 3, 2026
Jun 29, 2026A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 3rd STORYOct 2, 2026
Jun 29, 2026BApt 5 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE OUTLET AT NORTH WALL IN THE 5th ROOM FROM NORTH LOCATED AT APT 5, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTAug 3, 2026
Jun 29, 2026B§ 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE THROUGHOUT YARDAug 3, 2026
Jun 29, 2026BApt 5 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRIC VENTILATION AT CEILING IN THE BATHROOM LOCATED AT APT 5, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTAug 3, 2026
Apr 29, 2026BApt 1B · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 1B LOWER LEVEL, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTJun 3, 2026
Apr 29, 2026BApt 1B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 1B LOWER LEVEL, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTJun 3, 2026
Apr 29, 2026BApt 1B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTJun 3, 2026
Apr 29, 2026AApt 1B · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE FOYER LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTAug 2, 2026
Apr 29, 2026AApt 1B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE FOYER LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTAug 2, 2026
Apr 29, 2026CApt 1B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTMay 25, 2026
Apr 29, 2026CApt 1B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTMay 25, 2026
Apr 29, 2026BApt 5 · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE TOILET SEAT COVER IN THE BATHROOM LOCATED AT APT 5, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTJun 3, 2026
Apr 29, 2026BApt 5 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL VENTILATION SYSTEM AT CEILING IN THE BATHROOM LOCATED AT APT 5, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTJun 3, 2026
Apr 29, 2026B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT PLASTER AT CEILING IN BOILER ROOM AT NORTH AT BASEMENTJun 3, 2026
Jan 26, 2026BApt 1B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTMar 2, 2026
Jan 26, 2026CApt 5 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTFeb 21, 2026
Jan 26, 2026BApt 5 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SEAL AT LOWER REFRIGERATOR DOOR IN THE KITCHEN LOCATED AT APT 5, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTMar 2, 2026
Jan 6, 2026B§ 27-2021 ADM CODE PROVIDE SUFFICIENT, PROPER AND SEPARATE METAL RECEPTACLES FOR THE DEPOSIT OF GARBAGE, RUBBISH AND OTHER WASTE MATERIAL AND ARRANGE FOR COLLECTION AND DISPOSAL OF SUCH MATERIAL.Feb 10, 2026
Dec 24, 2025B§ 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE FRONT YARDJan 28, 2026
Aug 21, 2024B§ 27-2021 ADM CODE PROVIDE SUFFICIENT, PROPER AND SEPARATE METAL RECEPTACLES FOR THE DEPOSIT OF GARBAGE, RUBBISH AND OTHER WASTE MATERIAL AND ARRANGE FOR COLLECTION AND DISPOSAL OF SUCH MATERIAL.Sep 25, 2024
Jan 24, 2024BApt 1F · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 1SQFT AT SOUTH WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 16243658 ISSUED 22-SEP-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §Feb 28, 2024
Sep 26, 2023BApt 1F · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR (UP 3 INCH) IN THE 1st ROOM FROM EAST LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTOct 31, 2023
Sep 26, 2023AApt 1F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTDec 30, 2023
Sep 26, 2023AApt 1F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 1F, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTDec 30, 2023
Jul 26, 2023CApt 1R · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT ENTRANCE TO LEADING TO REAR YARD IN THE 3rd ROOM FROM NORTH AT WEST LOCATED AT APT 1R, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTAug 9, 2023
Jul 5, 2018B§ 27-2010, 2011, 2012 ADMIN. CODE: REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE FRONT BUILDINGAug 9, 2018

Issued in the last 120 days

DateSourceWhatNow
Sep 22, 2026HPD B§ 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE AT BUILDING FRONT YARDOpen
Sep 22, 2026HPD B§ 27-2005 ADM CODE PROPERLY SECURE THE LOOSE HANDRAIL AT PUBLIC HALL STAIRS, 1st STORYOpen
Sep 22, 2026HPD B§ 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE BUILDING FRONT YARDOpen
Sep 21, 2026HPD B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE HANDRAIL AT 3RD STORY PUBLIC HALL AT PUBLIC HALL STAIRS, 3rd STORYOpen
Aug 6, 2026HPD C§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MORE THAN 10 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 18812730 ISSUED 25-APR-26 HAS BEEN UPGRADED TO CLASS C PER ADMINISTRATIVE CODE 27-2017.Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 14, 2026, 1:08 PM ET. BBL 3040340025.