5 floors · 40 apartments · 39,410 sq ft · built 1896 · class D3 · owner of record: Nyc Housing Authority
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 47 days | Annual |
| Annual boiler inspection (6 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-11-18 (Accepted). Agency page | Dec 31, 2026 in 47 days | 6 of 6 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 63 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 39,410 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 168 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 168 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1143 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| May 7, 2025 | Construction CLASS - 2 PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. NOTE: AT TIMEOF INSPECTION OBSERVED AT SIDEWALK SHED PARAPET WALL OBSERVED HANGING LOOSE WOOD WITH LEAVES AND OTHER JUNK PUSHING IT DOWN THIS IS CAR SIDE #35693740H | Feb 5, 2026 IN VIOLATION | $0 |
| Apr 9, 2025 | Construction CLASS - 2 FAILURE TO COMPLY WITH CODES 3307.6.2, 3307.6.3, 3307.6.3 AND SECTIONS, CREATING A HAZARDOUS OF POTENTIAL AND EXPOSE PUBLIC TO DANGER. OBSERVED SIDEWALK SHED MISSING FIVE FEET EXTENSION AT EXPOSURE ONE BY EXPO #39538915X | Jun 26, 2025 ADMIT/IN-VIO | $0 |
| Mar 27, 2024 | Construction CLASS - 2 PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. NOTE: I OBSERVED A SIDEWALK SHED ERECTED AT EXPO# 1 WITH MISSING 5 FEET EXTENSION AT EXPO# 2 AS REQUIRED BY CODE (BC 3307.6.2, COMPLY TO CODE SPECIFICATI #39109989N | Oct 30, 2025 IN VIOLATION | $2,400 |
| Nov 16, 2023 | Construction CLASS - 2 AT TIME OF INSPECTION OF 5 STORY BUILDING OBSERVED SIDEWALK SHED IN PLACE MISSING PARAPET PANEL NOT COMPLIANT AS PER 3307.6.4.6INSTALL PANEL #39523421Y | Jun 17, 2025 IN VIOLATION | $2,400 |
| Oct 4, 2023 | Construction CLASS - 2 5 STORY LANDMARK BUILDING, RESPONDING TO SIDEWALK SHED(SWS) COMPLAINT, I OBSERVED SWS AT EXP1, DOES NOT EXTEND 5FEET PAST PROPERTY LINES EXP2&4 AS REQUIRED BY BC3307.6.3(1). ALSO, SWS SIGN ON PARAPET PANEL IS P #39522327N | May 9, 2024 IN VIOLATION | $625 |
| Issued | Violation | Status |
|---|---|---|
| May 7, 2024 | CONSTRUCTION FAILURE TO MAINTAIN BUILDIKNG IN A CODE COMPLIANT MANNER. OBSERVED AT EXP#1 MULTIPLE SPALLING CRACKED BROKEN FACADE. MULTIPLE AREAS OF READY TO FALL AT ANY MOMENT. AT EXP#4 OBSERVED WINDOW FRAMES BROKEN/SPALLING AND MULTIPLE CRACKS. REMEDY: REPAIR AND/OR REPLACE #SR10702DO | DOB VIOLATION - ACTIVE |
None open.
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)