Manhattan · Block 1127 · Lot 59 · 10023

54 West 75 Street

4 floors · 10 apartments · 7,124 sq ft · built 1891 · class C5 · owner of record: 54w75 Owner Llc

11open violations
$0ECB/OATH penalties owed
2HPD class C (immediately hazardous)
51dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 51 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 51 days
Annual
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-04-29 (Accepted). Agency page

Dec 31, 2026
in 51 days
1 of 1 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 67 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 295 days
Registered through 2027-09-01
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1147 days
Next cycle year 2029

Open violations

ECB / OATH (0)

None open.

DOB (0)

None open.

DOB NOW Safety (1)
IssuedViolationStatus
Sep 18, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle B (premises is in Community District 7)
Active
HPD (10) · C 2 · B 7 · A 0
IssuedClassViolationCorrect by
Dec 8, 2020I§ 27-2089 ADM CODE THE PREMISES HAVE BEEN VACATED BY AN ORDER OF THIS DEPARTMENT AND CANNOT BE REOCCUPIED EXCEPT FOR CARETAKER UNTIL A NEW CERTIFICATE OF OCCUPANCY HAS BEEN OBTAINED. ENTIRE BUILDING UNDER VACATE #157945—
Apr 12, 2024C§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF PADLOCKABLE EYES INSTALLED AT SCUTTLE HATCH LEADING TO ROOF AT PUBLIC HALL, 4th STORYApr 18, 2024
Apr 12, 2024B§ 27-2050 ADM CODE PROVIDE A PIECE OF GARDEN HOSE 10 FEET IN LENGTH WITH FEMALE COUPLING AND A 10 QUART PAIL ON PREMISES TO TEST SPRINKLER SYSTEM.May 17, 2024
Apr 12, 2024BApt 1A · § 27-2081 ADM CODE DISCONTINUE USE OF ROOMS FOR LIVING PURPOSES SLEEPING IN CELLAR USED IN CONJUCTION WITH BASEMENT APARTMENT (DUPLEX APARTMENT) IN THE 3rd ROOM FROM NORTH LOCATED AT BSMT-APT 1A LOWER LEVEL, 1st BSMT-APT FROM EAST AT SOUTHMay 17, 2024
Apr 12, 2024CApt 1B · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 19; WG TO REPLACE = 0; WG TO REPAIR = 0; DUPELX APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 1B, May 8, 2024
Apr 8, 2024B(B) 27-2141(C) HMC: ORDER TO REPAIR/VACATE ORDER MUST REMAIN POSTED UNTIL SUCH TIME AS THE ORDER IS RESCINDED. A COPY FOR POSTING CAN BE FOUND THROUGH HPDONLINE (WWW.NYC.GOV/HPD). AT PUBLIC HALLMay 13, 2024
Apr 5, 2024BApt 1A · (B) 27-2142(A) HMC: THE FOLLOWING DWELLING UNITS WERE REOCCUPIED WHILE BEING SUBJECT TO AN ORDER TO REPAIR/VACATE ORDER ISSUED BY THE DEPARTMENT; FILE FOR A DISMISSAL REQUEST RELATED TO THE ISSUED ORDER (SEE WWW.NYC.GOV/HPD). IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SMay 10, 2024
Apr 5, 2024BApt 1B · (B) 27-2142(A) HMC: THE FOLLOWING DWELLING UNITS WERE REOCCUPIED WHILE BEING SUBJECT TO AN ORDER TO REPAIR/VACATE ORDER ISSUED BY THE DEPARTMENT; FILE FOR A DISMISSAL REQUEST RELATED TO THE ISSUED ORDER (SEE WWW.NYC.GOV/HPD). IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM EMay 10, 2024
Apr 5, 2024BApt 4B · (B) 27-2142(A) HMC: THE FOLLOWING DWELLING UNITS WERE REOCCUPIED WHILE BEING SUBJECT TO AN ORDER TO REPAIR/VACATE ORDER ISSUED BY THE DEPARTMENT; FILE FOR A DISMISSAL REQUEST RELATED TO THE ISSUED ORDER (SEE WWW.NYC.GOV/HPD). IN THE ENTIRE APARTMENT LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM SMay 10, 2024
Apr 5, 2024BApt 4A · (B) 27-2142(A) HMC: THE FOLLOWING DWELLING UNITS WERE REOCCUPIED WHILE BEING SUBJECT TO AN ORDER TO REPAIR/VACATE ORDER ISSUED BY THE DEPARTMENT; FILE FOR A DISMISSAL REQUEST RELATED TO THE ISSUED ORDER (SEE WWW.NYC.GOV/HPD). IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 2nd APARTMENT FROM SMay 10, 2024

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 10, 2026, 6:14 AM ET. BBL 1011270059.

Look up another building