5 floors · 8 apartments · 9,010 sq ft · built 1920 · class C7 · owner of record: Shaban Enterprises,Inc.
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 44 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 44 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 60 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 288 days | Registered through 2027-09-01 |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 775 days | Next cycle year 2028 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-10-23 (Accepted). Agency page | On file | 2026 reports accepted |
None open.
None open.
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jun 27, 2025 | C | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VERTICAL CRACK ABOVE 3RD KEYSTONE FROM EAST AT 5TH STORY NORTH EXTERIOR WALL UP TO PARAPET WALL AT ROOF | Jul 3, 2025 |
| Jun 27, 2025 | C | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VERTICAL CRACK WITH MISSING MORTAR JOINTS, AND LOOSE BRICKS AT EAST EXTERIOR WALL FROM 3RD STORY UP TO PARAPET WALL AT ROOF | Jul 3, 2025 |
| Jun 27, 2025 | B | § 27-2005 ADM CODE PROVIDE GLASS IN PLACE OF PLEXIGLASS INSTALLED AT UPPER AND LOWER PANE AT DOOR FROM STREET TO VESTIBULE AT 1ST STORY AT PUBLIC HALL | Aug 1, 2025 |
| Jun 27, 2025 | B | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF PLEXIGLASS INSTALLED AT UPPER AND LOWER PANE AT DOOR FROM STREET TO VESTIBULE AT 1ST STORY AT PUBLIC HALL | Aug 1, 2025 |
| Sep 23, 2024 | C | Apt 1E · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR IN THE ENTRANCE LOCATED AT APT 1E, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Oct 7, 2024 |
| Sep 23, 2024 | B | Apt 1E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 1E, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Oct 28, 2024 |
| Sep 23, 2024 | C | Apt 1E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1E, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Oct 19, 2024 |
| Sep 23, 2024 | C | Apt 1E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1E, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Oct 19, 2024 |
| Sep 23, 2024 | B | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF PLEXI GLASS AT DOOR FROM STREET TO VESTIBULE AT 1ST STORY AT PUBLIC HALL | Oct 28, 2024 |
| Sep 23, 2024 | B | § 27-2005 ADM CODE PROVIDE GLASS IN PLACE OF PLEXI GLASS AT DOOR FROM STREET TO VESTIBULE AT 1ST STORY AT PUBLIC HALL | Oct 28, 2024 |
| Sep 18, 2015 | B | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDENT MATERIAL AT CELLAR CEILINGS THRU-OUT | Oct 23, 2015 |
| Sep 18, 2015 | B | SECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS AT BOILER ROOM DOOR | Oct 23, 2015 |
| Sep 18, 2015 | B | SECTION 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE REAR YARD | Oct 23, 2015 |
| Oct 6, 2014 | B | Apt 4W · SECTION 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTE LINE PIPE AT TUB IN THE BATHROOM LOCATED AT APT 4W, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 10, 2014 |
| Oct 6, 2014 | B | Apt 4W · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE CORRODED METAL BASE CABINET AT SINK IN THE KITCHEN LOCATED AT APT 4W, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 10, 2014 |
| Oct 6, 2014 | B | Apt 4W · SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 3rd ROOM FROM NORTH LOCATED AT APT 4W, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 10, 2014 |
| Mar 27, 2009 | B | Apt 2W · SECTION 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN BED BUGS IN THE ENTIRE APARTMENT LOCATED AT APT 2W, 2nd STORY, APARTMENT AT WEST | May 1, 2009 |
| Mar 15, 2007 | B | Apt 2W · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE RUBBER GASKETAT LOWER DOOR OF REFRIDGERATOR IN THE KITCHEN LOCATED AT APT 2W, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Apr 24, 2007 |
| Mar 15, 2007 | B | Apt 2W · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE COUNTER BALANCES AT LOWER SASH IN THE KITCHEN LOCATED AT APT 2W, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Apr 24, 2007 |
| Mar 15, 2007 | B | Apt 2W · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2W, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Apr 24, 2007 |
| Mar 15, 2007 | B | Apt 2W · SECTION 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN BEDBUGS IN THE ENTIRE APARTMENT LOCATED AT APT 2W, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Apr 24, 2007 |
| May 18, 2000 | B | Apt 1W · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRIC WIRE AT SOUTH WALL IN THE FOYER LOCATED AT APT 1W, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 27, 2000 |
| May 18, 2000 | B | SECTION 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION .. AT PUBLIC HALL, 3rd STORY | Jun 27, 2000 |
| May 18, 2000 | B | SECTION 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION .. AT PUBLIC HALL, 2nd STORY | Jun 27, 2000 |
| May 18, 2000 | A | Apt 1W · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WOOD DOOR IN THE FOYER LOCATED AT APT 1W, 1st STORY, APARTMENT AT WEST | Aug 26, 2000 |