4 floors · 582,919 sq ft · built 1925 · class W1 · owner of record: Nyc Department Of Education
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 58 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 582,919 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 179 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 179 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 423 days | Next cycle year 2027 |
| Energy audit and retro-commissioning (2030) Likely applies Local Law 87 · Calendar year 2030 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2160). Agency page | Dec 31, 2030 in 1519 days | Next due 2030 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-06-03 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 30, 2026 | Construction CLASS - 1 AT THE TIME OF INSPECTION, ACTIVE MASONRY WORK CONSISTING OF THE CONSTRUCTION/RECONSTRUCTION OF A BRICK MASONRY WALL WAS OBSERVED. NO VALID DEPARTMENT OF BUILDINGS WORK PERMIT WAS AVAILABLE FOR THE OBSERVED WOR #39198546L | Sep 3, 2026 POP/IN-VIO | $0 |
| Feb 20, 2026 | Construction CLASS - 2 REISSUE ON ECB #35688748X. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: UPON INSPECTION REAR BUILDING EXIT #4 TUNNEL RETAINING WALL IN DISREPAIR WITH MULTIPLE CRACKS AND MISSING MORTAR. REMEDY: #35729082R | Mar 12, 2026 POP/IN-VIO | $0 |
| Feb 20, 2026 | Construction CLASS - 2 REISSUE ON ECB #35688746M. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: UPON INSPECTION FIRE RATED SMOKE DOORS NOT SELF-CLOSING PROPERLY ON STAIR B 1ST FL, STAIR A 1ST FL, AUDITORIUM DOOR(4) ON #35729080N | Mar 12, 2026 POP/IN-VIO | $0 |
| Feb 20, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: UPON INSPECTION SPALLING FALLEN PLASTER AND WATER LEAK IN AUDITORIUM WITH PLASTER DEBRIS ON AUDITORIUM CHAIRS AND FLOOR. REMEDY: REPAIR AND/OR REPLA #35729085M | Mar 12, 2026 POP/IN-VIO | $0 |
| Feb 20, 2026 | Construction CLASS - 2 REISSUE ON ECB #35688745K. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1; 27-381. NOTED: UPON INSPECTION, EMERGENCY ILLUMINATI #35729081P | Mar 12, 2026 POP/IN-VIO | $0 |
| Feb 20, 2026 | Construction CLASS - 2 EXIT DOOR NOT SELF-CLOSING. NOTED: UPON INSPECTION EXTERIOR DOOR EXIT 2 NOT SELF-CLOSING EXIT 1 MAIN ENTRANCE EXIT 1, EXIT 3, EXIT 7, GIRLS SQUARE 1ST FL C AND D MAIN ENTRANCE, EXIT A- STAIRCASE. REMEDY: REPAIR #35729084K | Mar 12, 2026 POP/IN-VIO | $0 |
| Feb 20, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: UPON INSPECTION FIRE RATED CLASSROOM DOORS NOT SELF-CLOSING DUE TO BINDING OR HARDWARE ON 410, 407, 405, 406, 404, 403, 302, 305, 304, 307, 308, 336 #35729083Z | Mar 12, 2026 POP/IN-VIO | $0 |
| Feb 20, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: UPON INSPECTION EXIT 1 BRICK COLUMN MISSING MORTAR AND BRICK AT BASE OF COLUMNINCLUDING EXIT 4 ALSO MISSING MORTAR AND BRICK AT BASE OF BRICK FENCE #35729086Y | Mar 12, 2026 POP/IN-VIO | $0 |
| Feb 20, 2026 | Construction CLASS - 2 REISSUE ON ECB #35688747Y. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: UPON INSPECTION WIRE MESH GLASS PANELS MISSING IN STAIRCASE K AND L, INCLUDING 508 CRACKED VISION PANEL, AND 241 CRACKED #35729079X | Mar 12, 2026 POP/IN-VIO | $0 |
| Feb 20, 2025 | Construction CLASS - 2 REISSUE: 35677313N FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: FIREPROOF DOOR THROUGHOUT ARE NOT SELF-CLOSING. 3RD FLOOR CORRIDORBY RM 326, 2FL STAIR B, 1FLR-GYM/STAIR F EXIT. REMEDY: COMPLY WITH COD #35688746M | Apr 30, 2025 POP/IN-VIO | $0 |
| Feb 20, 2025 | Construction CLASS - 2 REISSUE: 35677314P-FAILURE TO MAINTAIN BLDG. IN CODE-COMPLIANT MANNER:ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDOR PER BC 1006.1; 27-381-ILLUMINATION FOR EXIT SIGNS AT AUDITORIUM ARE NOT WORKING. #35688745K | Apr 30, 2025 POP/IN-VIO | $0 |
| Feb 20, 2025 | Construction CLASS - 2 REISSUE: 35674701L-FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: REAR BUILDING EXIT #4 TUNNEL RETAINING WALL IN DISREPAIR W/MULTIPLE CRACKS. REMEDY: COMPLY WITH CODE. #35688748X | Apr 30, 2025 POP/IN-VIO | $0 |
| Feb 20, 2025 | Construction CLASS - 2 REISSUE: 35677312L-FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: WIRE MESH GLASS PANELS ARE MISSING THROUGHOUT. REMEDY: COMPLY WITHCODE. #35688747Y | Apr 30, 2025 POP/IN-VIO | $0 |
| Nov 1, 2024 | Construction CLASS - 2 OBSERVED AT THE CORNER LOT OF SCHOOL, 17 TEMP. CLASSROOM UNITS. EACH UNIT IS 1 STORY WITH 2 CLASSES EACH. NO RECORDS ON FILE AS FAR A C OF O., DISCONTINUE ILLEGAL OCCUPANCY OR AMEND C OF O #39129263M | Nov 20, 2024 POP/IN-VIO | $0 |
| Mar 26, 2024 | Construction CLASS - 2 OPERATION OF A PLACE OF ASSEMBLY WITHOUT A CURRENT CERTIFICATE OF OPERATION. NOTED: OBSERVED AT 2 FLR.-RM. #252/MUSIC ROOM HAS BEEN SET UP WITH APPROX. 100 SEATS BOLTED TO THE GROUND AND STAGE TOWARDS THE RIGHT #35677316Z | May 15, 2024 POP/IN-VIO | $0 |
| Mar 26, 2024 | Construction CLASS - 2 RE-ISSUE #35674703P-FAILURE TO MAINTAIN BUILDING IN CODE-COMLIANT MANNER. NOTED: OBSERVED WIRE MESH GLASS PANELS ARE MISSING AND/OR BROKEN AT 3 FLR.-STAIR 'K' APPROX. 2 FLR.-STAIR 'E' AND 'F' ALSO STAIR 'K' AND #35677312L | May 15, 2024 POP/IN-VIO | $0 |
| Mar 26, 2024 | Construction CLASS - 2 RE-ISSUE #35674701L-FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: OBSERVED INTERIOR FIREPROOF SELF CLOSING DOORS AT 3 FLR.-CORRIDOR BY RM. #326, 2 FLR.-STAIR 'B', 1 FLR.-GYM/STAIR 'F' EXIT, 1 FL #35677313N | May 15, 2024 POP/IN-VIO | $0 |
| Mar 26, 2024 | Construction CLASS - 2 RE-ISSUE #35672549R-FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDOR PER BC1006.1; 27-381. NOTED: OBSERVED AT 1 FLR.-AUDITORIUM APPROX. 4-EMERGE #35677314P | May 15, 2024 POP/IN-VIO | $0 |
| Jun 16, 2023 | Construction CLASS - 2 REISSUE #35657939H FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27-381. NOTED EMERGENCY LIGHTS NOT OPERATIONAL WHEN TESTED AT #35672549R | Nov 2, 2023 POP/IN-VIO | $0 |
| Jun 16, 2023 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED INTERIOR FIRE PROOF SELF CLOSING DOORS NOT CLOSING PROPERLY AT 4TH FL STAIR WELL K DOOR IS RACKED, AT 3RD FLOOR SMOKE DOORS BY RM 326 REMAIN STUCK IN #35674701L | Nov 2, 2023 POP/IN-VIO | $0 |
| Jun 16, 2023 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED PARKING LOT NEXT TO TRACK FIELD IN DISREPAIR WITH MISSING PATCHES OF ASPHALT, HOLES & BULDGING AREAS OF CONCRETE AT EXIT #4 PATHWAY. ADDITIONALLY TRA #35674702N | Nov 2, 2023 POP/IN-VIO | $0 |
| Jun 16, 2023 | Construction CLASS - 2 REISSUE #35657837X. FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED AT REAR OF THE BUILDING, EXIT #4 TUNNEL, RETAINING WALL IN DISPAIR WITH MULTIPLE CRACKS. REMEDY: REPAIR/REPLACE #35674700J | Nov 2, 2023 POP/IN-VIO | $0 |
| Jun 9, 2022 | Construction CLASS - 2 REISSUE#35561218K.DATE 6/21/2021.FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.AT THE TIME OF INSPECTION,I OBSERVED AT REAR OF THE BUILDINGIN THE EXIT 4,THE TUNNEL AT REAR RETAINING WALL IS CRACKED WIT #35657837X | Oct 27, 2022 POP/IN-VIO | $0 |
| Jun 9, 2022 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.ILLUMINATION FOREXITS,EXIT DISCHARGES,AND PUBLIC CORRIDORS PER BC1006.1;27-381.AT THE TIME OF INSPECTION,I OBSERVED ON 1ST FLOOR LEVEL AT GYM,TWO EMERGENCY #35657838H | Oct 27, 2022 POP/IN-VIO | $0 |
| Jun 21, 2021 | Construction CLASS - 2 REISSUE35495759K FAILURE TO MAINTAIN BLDG IN CODECOMPLIANT MANNER NOTED@REAR OF BLDG MASONRY TUNNEL HAS NUMEROUS LOCATIONS OF CRACKED &/OR MISSING MASONRY.COMPLY W/CODE. #35561218K | Sep 30, 2021 POP/IN-VIO | $0 |
| May 26, 2020 | Construction CLASS - 2 REISSUE #35423220Y FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER NOTED AT TIME OF INSPECTION I OBSERVED AT EXIT "4" BASEMENT LEVEL IN THE TUNEL A REAR A RETAININGW ALL CRACKED/MISSING MASONRY NEED TO RE #35495759K | Sep 3, 2020 POP/IN-VIO | $0 |
| May 16, 2019 | Construction CLASS - 2 RE-ISSUE #35326180Y.FAILURE TO MAINTAIN BLD. IN CODE COMPLIANT MANNER.AT EXIT-"4"BASEMENT LEVEL,REAR RETAINING WALL CRACKED/MISSING MASONRY.REM:REPAIR AND/OR REPLACE. #35423220Y | Aug 8, 2019 POP/IN-VIO | $0 |
| Mar 29, 2018 | Construction CLASS - 2 REISSUE #35214085J FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER AT EXIT 4 REAR RETAINING WALL CRACKED/MISSING MASONRY. RMDY: REPAIR/REPLACE #35326180Y | Aug 30, 2018 POP/IN-VIO | $0 |
| May 24, 2017 | Construction CLASS - 2 REISSUE#35207473X FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES.NOTED WALLS @ EXIT 4 RETAINING WALL TO TO EXIT SPALLING MISSING & PURGING SECTIONS OF RETAINING WALL.REM MAINTAIN EXTERIOR BLDG WALL #35267458M | Aug 31, 2017 POP/IN-VIO | $0 |
| Sep 14, 2016 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED: AT EXIT 4, RETAINING WALL,UNDER SCHOLL ENTERENCE, IS SPALLING, PARGING AND MISSING SECTIONS. RMDY: COMPLY WITH CODE. #35214085J | Jan 5, 2017 POP/IN-VIO | $0 |
| Sep 14, 2016 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. FAILURE TO MAINTAIN WALLS. AT EXIT 4 - RETAINING WALL TO EXIT SPALLING, MISSING AND PARGING SECTIONS OF RETAINING WALL. REISSUE NOV #35146813R. RMDY:COMPLY #35207473X | Jan 5, 2017 POP/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| May 1, 2024 | RETAINING WALL FAILED TO FILE CYCLE 1 TECHNICAL REPORT BY 12/31/2018 PER RCNY 103-09 #00004 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 21, 2026 | Retaining Walls Failure to file retaining wall cycle 3 report by 12/31/2025 | Active |
| May 1, 2024 | Retaining Walls FTF-RW-INITL | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 21, 2026 | DOB Safety | Retaining Walls: Failure to file retaining wall cycle 3 report by 12/31/2025 | Open |
| Jul 30, 2026 | ECB | Construction: AT THE TIME OF INSPECTION, ACTIVE MASONRY WORK CONSISTING OF THE CONSTRUCTION/RECONSTRUCTION OF A BRICK MASONRY WALL WAS OBSERVED. NO VALID DEPARTMENT OF BUILDINGS WORK PERMIT WAS AVAILABLE FOR THE OBSERVED WOR | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 3, 2026, 4:08 PM ET. BBL 1021600018.