3 floors · 2 apartments · 3,540 sq ft · built 1905 · class S2 · owner of record: Nihad And Ghada Owaid 2016 Revocable Fam Ily Trust
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 69 days | Keep the report on file (not filed with DOB) |
| Annual property registration Check HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 313 days | Required only if the owner doesn't live there |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 10 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 800 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 1, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING FACADE. AT TIME OF INSPECTION, OBSERVED AT EXPOSURE 1 (FRONT) CRACKED AND LOOSE SECTIONS OF STUCCO. ADDITIONALLY, AT EXPOSURE 4 (SIDE), THE PARAPET WALL EXHIBITED A DISPLACED SECTIO #39194526X | Sep 9, 2026 DEFAULT | $2,530 |
| Issued | Violation | Status |
|---|---|---|
| Jul 1, 2026 | CONSTRUCTION REQUESTING A STRUCTURAL STABILITY REPORT DUE TO DEFECTS OBSERVED AT EXPOSURE 4 OF PARAPET WALL. TOP SECTION OF PARAPET WALL IS MISSING WITH A DEFLECTION INWARD TOWARDS THE ROOF. #26-01695 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 16, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Sep 16, 2026 | DOB Safety | AEUHAZ: | Open |
| Jul 1, 2026 | DOB | CONSTRUCTION: REQUESTING A STRUCTURAL STABILITY REPORT DUE TO DEFECTS OBSERVED AT EXPOSURE 4 OF PARAPET WALL. TOP SECTION OF PARAPET WALL IS MISSING WITH A DEFLECTION INWARD TOWARDS THE ROOF. | Open |
| Jul 1, 2026 | ECB | Construction: FAILURE TO MAINTAIN BUILDING FACADE. AT TIME OF INSPECTION, OBSERVED AT EXPOSURE 1 (FRONT) CRACKED AND LOOSE SECTIONS OF STUCCO. ADDITIONALLY, AT EXPOSURE 4 (SIDE), THE PARAPET WALL EXHIBITED A DISPLACED SECTIO | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)