4 floors · 40,160 sq ft · built 1926 · class G1 · owner of record: Trustees Of Columbia University
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 9 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 46 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 46 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 40,160 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 167 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 167 days | Annual filing |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| May 8, 2026 | Construction CLASS - 1 FAILURE TO SUBMIT CERTIFICATE OF CORRECTION OF VIOLATION #39103878N ISSUED ON 01-21-2024 FOR FAILURE TO MAINTAIN BUILD, REPAIR AND/REPLACE #39187880N | Jan 14, 2027 PENDING | $6,250 |
| May 8, 2026 | Construction CLASS - 1 FAILURE TO SUBMIT CERTIFICATE OF CORRECTION OF VIOLATION #39085476Y ISSUED ON 05-04-2023 FOR FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT-MANNER., REPAIR AND/REPLACE #39187882R | Jan 14, 2027 PENDING | $6,250 |
| May 8, 2026 | Construction CLASS - 1 FAILURE TO SUBMIT CERTIFICATE OF CORRECTION OF VIOLATION #37025596L ISSUED ON 10-11-2023 FOR UNLAWFUL ACTS. FAILURE TO COMPLY WITH COMMISSIONER'S ORDER., COMPLY WITH COMMISSIONER'S ORDER #39187881P | Jan 14, 2027 PENDING | $6,250 |
| May 8, 2026 | Unknown CLASS - 1 FAILURE TO SUBMIT CERTIFICATE OF CORRECTION OF VIOLATION #35693656P ISSUED ON 05-07-2025 FOR FAILURE TO MAINTAIN - PARKING STRUCTURE., COMPLY WITH CODE. #39187879X | Jan 14, 2027 PENDING | $6,250 |
| May 1, 2026 | Unknown CLASS - 1 FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION. AT TIME OF INSPECTION ON AN OCCUPIED PARKING STRUCTURE CONSISTING OF 5 LEVELS, OBSERVED A SPALLED CONCRETE BEAM AT 4TH LEVEL/CRACKED CONCRETE BEAM AT 4TH #35729836Y | Jul 30, 2026 ADMIT/IN-VIO | $0 |
| May 7, 2025 | Unknown CLASS - 1 FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION. AS NOTED AT TIME OF INSPECTION ON AN OCCUPIED PARKING STRUCTURE CONSISTING OF 5 LEVELA, OBSERVED AT CELLAR LEVEL 1ST, 2ND, 3RD, 4TH FLOORS REINFORCED CON #35693656P | Jul 17, 2025 IN VIOLATION | $0 |
| Jan 21, 2024 | Construction CLASS - 1 SUMMONS ISSUED FOR FAILURE TO MAINTAIN DUE TO SECTION OF CONCRETE MISSING AT EXPOSURE 1 EXTERIOR 1 TOP OF ELEVATOR SHAFT, ALONG MULTIPLE VERTICAL CRACKS ON FACADE., REPAIR AND/REPLACE #39103878N | May 16, 2024 ADMIT/IN-VIO | $0 |
| Oct 11, 2023 | Construction CLASS - 1 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER IN DOB VIOLATION VIO23-01304, DATED 5/4/2023. RESPONDENT WAS REQUIRED TO SUBMIT AN ENGINEER'S REPORT CONCERNING STRUCTURALLY DEFICIENT CONDITIONS. AS OF 10/11/2023, A #37025596L | Mar 21, 2024 ADMIT/IN-VIO | $0 |
| May 4, 2023 | Construction CLASS - 1 OBSERVED AT FACED EXP#1 LEFT SIDE OF ELEVATOR SHAFT ABOVE FIRE ESCAPE LARGE SECTION OF CONCRETE HAS FALLEN OFF EXPOSING REBAR. THE OTHER SIDE OF THAT SAME ELEVATOR LARGE CRACK CAN BE SEEN GOING FROM THE ROOF LE #39085476Y | Aug 17, 2023 ADMIT/IN-VIO | $0 |
| May 4, 2023 | Construction CLASS - 2 EMERGENCY LIGHT NOT WORKING WHEN TESTED. AT ALL FLOORS, REPAIR/REPLACE LIGHTING; REPAIR AND / OR REPLACE LIGHTS #39085474K | Aug 17, 2023 ADMIT/IN-VIO | $0 |
| Oct 3, 2009 | Unknown CLASS - 2 WORK WITHOUT A PERMIT. NOTED: AT 3RD FLOOR NEAR NOW EXIT A FULL HEIHGTMASONRY WALL WAS REMOVED. REM: OBTAIN PERMIT OR RESTORE PREMISES TO PRIOR LEGAL CONDITIONS. #34810060H | Dec 3, 2009 IN VIOLATION | $0 |
| Apr 10, 2006 | Construction Hazardous FAILURE TO MAINTAIN EXTERIOR OF BLDG CONCRETE RE-BEAM ON THE NORTH ELEVATION IS DEFECTIVE. CONCRETE HAS BROKEN AWAY EXPOSING THE RE-BARS,WHICH ARE RUSTING. REMEDY:MAKE THE AREA SAFE.REMOVE & REPAIR CONCRETE BEA #34505312Y | Jul 13, 2006 DEFAULT | $0 |
| Nov 5, 2005 | Construction Hazardous FAILURE TO MAINTAIN EXTERIOR OF BLDG. CONCRETE BEAM IS DEFECTIVE ON THE NORTH ELEVATION ON THE 1ST & 2ND FLRS. CONCRETE HAS BROKEN AWAY RE-BARS ARE EXPOSED & ARE RUSTING. REMEDY: MAKE THE AREA SAFE. REMOVE & RE #34502104X | Oct 11, 2007 DEFAULT | $0 |
| Oct 6, 1998 | Elevators Non-Hazardous 73 REMOVED #38078953X | Dec 3, 1998 WRITTEN OFF | $0 |
| Oct 6, 1998 | Elevators Non-Hazardous 73 REMOVED WORK WITHOUT PERMIT. #38078954H | Dec 3, 1998 WRITTEN OFF | $0 |
| Oct 6, 1998 | Elevators Non-Hazardous 73, REMOVED WORK WITHOUT PERMIT. #38078952Y | Dec 3, 1998 WRITTEN OFF | $0 |
| Jul 28, 1992 | Elevators Non-Hazardous 18X,02M,53M,73#,46T, 73. PERFORM 5 YEAR TEST FILE WITH CITY-TAG GOVERNOR. #38024697M | Nov 19, 1992 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| May 7, 2025 | CONSTRUCTION EMERGENCY WORK ORDER-OBSV @ CELLAR 1,2,3,4 LEVEL REINFORCED CONC COLMN APPEARS TO BE IN STATE OF DISPAIR W/SUBSTANTIAL CONC SPALLING AND CRACKING.STEEL REINFORCED ELEMENTS OF THE STRUCT ARE EXTENSIVELY CORRODED & EXPOSED W/SPALLED CONC COVER. IMMED RETAIN A NYSPE W/QPSI CERT TO OEVERSEE THE REMAVAL #PS109JL02 | DOB VIOLATION - ACTIVE |
| Apr 3, 2024 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00040 | DOB VIOLATION - ACTIVE |
| Oct 4, 2023 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00665 | DOB VIOLATION - ACTIVE |
| May 4, 2023 | CONSTRUCTION OBSERVED AT FACED EXP#1 LEFT SIDE OF ELEVATOR SHAFT ABOVE FIRE ESCAPE LARGE SECTION OF CONCRETE HAS FALLEN OFF EXPOSING REBAR. THE OTHER SIDE OF THAT SAME ELEVATOR LARGE CRACK CAN BE SEEN GOING FROM THE ROOF LEVEL TO THE TOP. INSIDE THE PARKING GARAGE AT ALL FLOORS VARIOUS AMOUNT OF HOLLOW CLAY BLOC #23-01304 | DOB VIOLATION - ACTIVE |
| May 4, 2023 | IMMEDIATE EMERGENCY PROVIDE APPROXIMATELY 110 LINEAR FEET OF SIDEWALK SHED ALONG THE ENTIRE FRONT ( EXPOSURE#1) OF BUILDING #17594 | DOB VIOLATION - ACTIVE |
| Jan 13, 1997 | LOCAL LAW 10/81 - ELEVATOR #01667 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 23, 2026 | Parking Structures FTF-PS-INITL Failure to file parking structures compliance report by 12/31/2025 as required per 1 RCNY 103-13 | Active |
| Jun 24, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Jun 15, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Jun 15, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Jun 15, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Apr 3, 2024 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 4, 2023 | AEUHAZ FTC-AEU-HAZ | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Sep 23, 2026 | DOB Safety | Parking Structures: Failure to file parking structures compliance report by 12/31/2025 as required per 1 RCNY 103-13 | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 15, 2026, 4:02 PM ET. BBL 1019760056.