Brooklyn · Block 5669 · Lot 65 · 11219

5301 New Utrecht Avenue

3 floors · 2 apartments · 4,620 sq ft · built 1931 · class S2 · owner of record: United Talmud Acad/B/Pk

4open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
411dto Gas piping inspection (2027 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 46 days
Keep the report on file (not filed with DOB)
Annual property registration Check
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 290 days
Required only if the owner doesn't live there
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 411 days
Next cycle year 2027

Open violations

ECB / OATH (2)
IssuedViolationHearingBalance
Dec 22, 2011Plumbing CLASS - 2
SEC. 27-902 FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER RE: INSTALLATION OF PLUMBING MATERIALS PER P.C. 102.3;27-902. AT THE 2ND FL LOCATION I OBSERVED 1 - RESIDENTIAL GAS FLEX'S WERE USED TO CONNECT
#34930173K
Mar 19, 2012
IN VIOLATION
$0
Dec 22, 2011Plumbing CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER: LACK OF A SYSTEM OF AUTOMATIC SPRINKLERS WHERE REQUIRED PER B.C. 903.2 27-954. AT THELOCATIONS OF 3RD FL IN THE BUILDING HAS WOODEN FLOORS,WOODEN RAFTERS &
#34930174M
Mar 19, 2012
IN VIOLATION
$0
DOB (1)
IssuedViolationStatus
Mar 21, 2012FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00139
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Mar 21, 2012AEUHAZ FTC-AEU-HAZ
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 15, 2026, 12:21 PM ET. BBL 3056690065.