Manhattan · Block 1392 · Lot 25 · 10075

53 East 77 Street

6 floors · 12,534 sq ft · built 1901 · class O2 · owner of record: 77 Jv Llc

14open violations
$8,400ECB/OATH penalties owed
0HPD class C (immediately hazardous)
46dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 46 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 46 days
Keep the report on file (not filed with DOB)
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-05-19 (Accepted). Agency page

Dec 31, 2026
in 46 days
1 of 1 without an accepted 2026 report yet

Open violations

ECB / OATH (7) · $8,400 owed
IssuedViolationHearingBalance
Jul 29, 2026Unknown CLASS - 1
3301.6.4 OBS. MAKESHIFT WORK PLATFORMS CONSTRUCTED OF WOOD PLANKS SUPPORTED BY STRUCTURAL STEEL/SCAFFOLD MEMBERS. PLATFORM INSTALLATION DIDNOT CONFORM TO APPROVED CONSTR. DOCS.; APPROVED SCAFFOLD COMPONENTS A
#39557252H
Oct 8, 2026
IN VIOLATION
$0
Jul 29, 2026Construction CLASS - 1
OBS HYDRAULIC PUMP JACKS/SHORING POSTS SUPPORTING A TEMPORARY FREESTANDING FLOOR/STRUCTURAL ASSEMBLY NOT INDICATED ON THE DOB APPROVED PLANS.TEMP SUPPORT INSTALLATION WAS ERECTED&MAINTAINED WITHOUT APPROVED ENG
#39557249R
Oct 8, 2026
IN VIOLATION
$0
Jul 29, 2026Unknown CLASS - 2
3307.6.4.2.2 AT TIME OF INSPECTION, SIDEWALK SHED AT EXPOSURE #2 OBSERVED BEING USED FOR STORAGE OF MATERIALS, DEBRIS, AND EQUIPMENT,SHANTY INCLUDING ON TOP OF SHED ROOF. STORAGE NOT IN DESIGNATED AREA AND CONT
#39557258Z
Oct 8, 2026
IN VIOLATION
$2,500
Jul 29, 2026Unknown CLASS - 2
3314.4.4.5 OBS. ACCUM. CONSTR. DEBRIS & LOOSE MATERIALS STORED ON SUPPORTED SCAFFOLD PLATFORM. DEBRIS REDUCED USABLE WALKING/WORKING SURFACE AND CREATED TRIP HAZARDS FOR WORKERS. SUPPORTED SCAFFOLD WAS NOT MAI
#39557253J
Mar 5, 2027
$2,500
Jul 29, 2026Construction CLASS - 2
OBS. SIDEWALK SHED POSTS WITHIN AN ACTIVE VEHICULAR DRIVEWAY LACKED REQ'D HIGH VISIBILITY MARKINGS. UNMARKED POSTS CREATED AN IMPACT HAZARD TO VEHICLES ENTERING AND EXITING THE DRIVEWAY. SIDEWALK SHED WAS NOT M
#39557256P
Mar 5, 2027
$2,400
Jul 29, 2026Construction CLASS - 2
OBS. TEMP CONSTR. FENCE INSTALLED ALONG ACTIVE DRIVEWAY WAS NOT PAINTED HUNTER GREEN AND LACKED REQ'D VIEWING PORTS. FENCE DID NOT CONFORM TO APPROVED TEMPORARY PROTECTION REQUIREMENTS, OBSTRUCTED VISIBILITY FO
#39557257R
Mar 5, 2027
PENDING
$1,000
Jul 29, 2026Construction CLASS - 1
OBS. INADEQ. HOUSEKEEPING THROUGHOUT SIDEWALK SHED. CONSTR. DEBRIS, REFUSE, LOOSE MATS., SCAFFOLD COMPONENTS, MASONRY UNITS, PALLETS, TOOLS & STORED MATERIALS ACCUM. ON WALKING/WORKING SURFACES AND ACCESS WAYS,
#39557255N
Oct 8, 2026
IN VIOLATION
$0
DOB (3)
IssuedViolationStatus
May 15, 2014LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
#01105
DOB VIOLATION - ACTIVE
Oct 8, 2010ELEVATOR ANNUAL INSPECTION / TEST

#01911
DOB VIOLATION - ACTIVE
Dec 7, 1994CONSTRUCTION

#08M04
VIOLATION UNSERVED ECB-ACTIVE
DOB NOW Safety (7)
IssuedViolationStatus
Aug 29, 2025Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Report
Active
May 15, 2014Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
Active
Oct 8, 2010Elevators VCAT1
Active
Oct 8, 2010Elevators VCAT1
Active
Oct 8, 2010Elevators VCAT1
Active
Oct 8, 2010Elevators VCAT1
Active
Oct 8, 2010Elevators VCAT1
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Sep 2, 2026DOB SafetyAEUHAZ: Closed
Sep 2, 2026DOB SafetyAEUHAZ: Closed
Sep 2, 2026DOB SafetyAEUHAZ: Closed
Jul 29, 2026ECBConstruction: OBS. SUPPORTED SCAFFOLD AT EXP. 1, 2 & 3 NOT CONFORMING TO APPR. CD. OUTRIGGERS INSTALLED W/4 FT OUTREACH VS. APPR. 2 FT. BETA MAX 1,200-LB HOISTS USED WHERE 1,000-LB HOISTS WERE APPR. MASONRY FRAMES/4 FT FRAMEClosed
Jul 29, 2026ECBConstruction: OBS. SIDEWALK SHED NOT CONFORMING TO APPROVED DWGS. DEBRIS/MATERIALS INCL. SCAFFOLD SHANTY STORED ON TOP OF SHED AT EXP. 2. SHED MISSING REQ'D X-BRACES/BAYS AND RT. ANGLE PIPE CLAMPS; SEVERAL SHED POSTS OBSERVEClosed
Jul 29, 2026ECBUnknown: 3301.6.4 OBS. MAKESHIFT WORK PLATFORMS CONSTRUCTED OF WOOD PLANKS SUPPORTED BY STRUCTURAL STEEL/SCAFFOLD MEMBERS. PLATFORM INSTALLATION DIDNOT CONFORM TO APPROVED CONSTR. DOCS.; APPROVED SCAFFOLD COMPONENTS AOpen
Jul 29, 2026ECBConstruction: OBS HYDRAULIC PUMP JACKS/SHORING POSTS SUPPORTING A TEMPORARY FREESTANDING FLOOR/STRUCTURAL ASSEMBLY NOT INDICATED ON THE DOB APPROVED PLANS.TEMP SUPPORT INSTALLATION WAS ERECTED&MAINTAINED WITHOUT APPROVED ENGOpen
Jul 29, 2026ECBUnknown: 3307.6.4.2.2 AT TIME OF INSPECTION, SIDEWALK SHED AT EXPOSURE #2 OBSERVED BEING USED FOR STORAGE OF MATERIALS, DEBRIS, AND EQUIPMENT,SHANTY INCLUDING ON TOP OF SHED ROOF. STORAGE NOT IN DESIGNATED AREA AND CONTClosed
Jul 29, 2026ECBUnknown: 3314.4.4.5 OBS. ACCUM. CONSTR. DEBRIS & LOOSE MATERIALS STORED ON SUPPORTED SCAFFOLD PLATFORM. DEBRIS REDUCED USABLE WALKING/WORKING SURFACE AND CREATED TRIP HAZARDS FOR WORKERS. SUPPORTED SCAFFOLD WAS NOT MAIClosed
Jul 29, 2026ECBConstruction: OBS. SIDEWALK SHED POSTS WITHIN AN ACTIVE VEHICULAR DRIVEWAY LACKED REQ'D HIGH VISIBILITY MARKINGS. UNMARKED POSTS CREATED AN IMPACT HAZARD TO VEHICLES ENTERING AND EXITING THE DRIVEWAY. SIDEWALK SHED WAS NOT MClosed
Jul 29, 2026ECBConstruction: OBS. TEMP CONSTR. FENCE INSTALLED ALONG ACTIVE DRIVEWAY WAS NOT PAINTED HUNTER GREEN AND LACKED REQ'D VIEWING PORTS. FENCE DID NOT CONFORM TO APPROVED TEMPORARY PROTECTION REQUIREMENTS, OBSTRUCTED VISIBILITY FOOpen
Jul 29, 2026ECBConstruction: OBS. INADEQ. HOUSEKEEPING THROUGHOUT SIDEWALK SHED. CONSTR. DEBRIS, REFUSE, LOOSE MATS., SCAFFOLD COMPONENTS, MASONRY UNITS, PALLETS, TOOLS & STORED MATERIALS ACCUM. ON WALKING/WORKING SURFACES AND ACCESS WAYS,Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 15, 2026, 10:04 AM ET. BBL 1013920025.