Manhattan · Block 276 · Lot 59 · 10038

53 Catherine Street

5 floors · 38,000 sq ft · built 1924 · class M1 · owner of record: 53 Catherine Nyc Realty Lp

23open violations
$9,730ECB/OATH penalties owed
0HPD class C (immediately hazardous)
185dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 64 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 38,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 185 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 185 days
Annual filing
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 795 days
Next cycle year 2028

Open violations

ECB / OATH (6) · $9,730 owed
IssuedViolationHearingBalance
Oct 9, 2026Unknown CLASS - 2
AT THE TIME OF INSPECTION OF A 7-STORY BUILDING WITH A CELLAR, OBSERVED A CONSTRUCTION FENCE WITHOUT A PERMIT. UNPERMITTED INSTALLATION CREATES A POTENTIAL HAZARD TO PEDESTRIAN AND THE PUBLIC BECAUSE THE FENCE
#39560421R
Dec 17, 2026
PENDING
$1,250
Oct 9, 2026Construction CLASS - 2
ATOI, OBSERVED A SIDEWALK SHED IN PLACE WITH AN ACTIVE PERMIT. UPON INSPECTION, THE REQUIRED SIDEWALK SHED PARAPET INFORMATION PANEL WAS NOT PROVIDED, CONTRARY TO BC 3301.9.2. . FAILURE TO PROVIDE THE REQUIRED
#39560422Z
Dec 17, 2026
PENDING
$1,250
Oct 8, 2026Construction CLASS - 2
AT THE TIME OF MY INSPECTION I OBSERVED THAT THE SIDE WALK SHED INSTALLED DID NOT HAVE A INFORMATION PANEL.
#39560404P
Dec 17, 2026
PENDING
$2,400
Jul 13, 2026Construction CLASS - 2
AT THE TIME OF MY INSPECTION I OBSERVED THAT THERE WERE UNCAPPED BOLTS WITHIN THE WALKWAY UNDER THE SIDE WALK SHED AND THAT THERE WERE NO INFORMATION PANEL INSTALLED.
#39556534L
Sep 17, 2026
DEFAULT
$2,430
Apr 22, 2025Construction CLASS - 2
AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED INSTALLED ON EXPOSURE #1AND 2 WITH INOPERABLE LIGHT BULBS AT UNDERSIDE OF THE SHED TO BRING ILLUMINATION FAILURE TO PROVIDE LIGHTING CREATES UNSAFE AND MUGGING CO
#39539353H
Dec 11, 2025
IN VIOLATION
$2,400
Jul 30, 2008Elevators CLASS - 2
39O02.34O02.41T07.56Y13.77M07.98BB05.100BB05.64B09. 77 PROVIDE LIGHT UNDER CAR 98 5 YR EXPIRED 100 2YR EXPIRED 64REMOVE NYC DEVICE # READING 1P14625
#38189739R
Sep 25, 2008
WRITTEN OFF
$0
DOB (6)
IssuedViolationStatus
Jun 19, 2019ELEVATOR

#9027/656475
DOB VIOLATION - ACTIVE
Dec 1, 2016ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2015 INSPECTION/TEST
#00203
DOB VIOLATION - ACTIVE
Oct 31, 2014ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2013 INSPECTION/TEST
#00235
DOB VIOLATION - ACTIVE
Dec 13, 2011ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2010 INSPECTION/TEST
#00205
DOB VIOLATION - ACTIVE
Oct 8, 2010ELEVATOR ANNUAL INSPECTION / TEST

#00299
DOB VIOLATION - ACTIVE
Nov 19, 2004LOCAL LAW 10/81 - ELEVATOR

#00197
DOB VIOLATION - ACTIVE
DOB NOW Safety (12)
IssuedViolationStatus
Oct 2, 2026Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2025 Cat1 Test Report
Active
Oct 2, 2026Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2025 Periodic Inspection Report
Active
Jan 8, 2026Gas Piping - LL152 FTF-PL-PER
Cycle 2, Sub-cycle A (premises is in Community District 3)
Active
Aug 29, 2025Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Report
Active
Aug 29, 2025Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Report
Active
Sep 11, 2024Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Report
Active
Sep 11, 2024Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Report
Active
Dec 1, 2016Elevators EVCAT1
Active
Oct 31, 2014Elevators EVCAT1
Active
Dec 13, 2011Elevators EVCAT1
Active
Oct 8, 2010Elevators VCAT1
Active
Nov 19, 2004Elevators LL1081
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Oct 9, 2026ECBUnknown: AT THE TIME OF INSPECTION OF A 7-STORY BUILDING WITH A CELLAR, OBSERVED A CONSTRUCTION FENCE WITHOUT A PERMIT. UNPERMITTED INSTALLATION CREATES A POTENTIAL HAZARD TO PEDESTRIAN AND THE PUBLIC BECAUSE THE FENCEOpen
Oct 9, 2026ECBConstruction: ATOI, OBSERVED A SIDEWALK SHED IN PLACE WITH AN ACTIVE PERMIT. UPON INSPECTION, THE REQUIRED SIDEWALK SHED PARAPET INFORMATION PANEL WAS NOT PROVIDED, CONTRARY TO BC 3301.9.2. . FAILURE TO PROVIDE THE REQUIREDOpen
Oct 8, 2026ECBConstruction: AT THE TIME OF MY INSPECTION I OBSERVED THAT THE SIDE WALK SHED INSTALLED DID NOT HAVE A INFORMATION PANEL.Open
Oct 2, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Cat1 Test ReportOpen
Oct 2, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Periodic Inspection ReportOpen
Jul 13, 2026ECBConstruction: AT THE TIME OF MY INSPECTION I OBSERVED THAT THERE WERE UNCAPPED BOLTS WITHIN THE WALKWAY UNDER THE SIDE WALK SHED AND THAT THERE WERE NO INFORMATION PANEL INSTALLED.Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 28, 2026, 9:54 PM ET. BBL 1002760059.