3 floors · 114,000 sq ft · built 1924 · class K4 · owner of record: Fulton Square, Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 60 days | Keep the report on file (not filed with DOB) |
| Energy audit and retro-commissioning (2026) Likely applies Local Law 87 · Calendar year 2026 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 146). Agency page | Dec 31, 2026 in 60 days | Due this year |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2020-01-31 (Accepted). Agency page | Dec 31, 2026 in 60 days | 1 of 1 without an accepted 2026 report yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 114,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 181 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 181 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1156 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 21, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN, I OBSERVED HVAC UNIT ON ROOF LEAKING WATER ONTO ROOF FLOOR. AS PER PC 102.3 BOTH NEW AND EXISTING INSTALLATIONS SHALL BE MAINTAINED IN PROPER OPERATING CONDITION., REPAIR AND/OR REPLACE #39208658M | Jan 6, 2027 PENDING | $1,250 |
| May 10, 2023 | Construction CLASS - 2 ALT TYPE 1 ,CHANGE OF OCCUPANCY IN CELLAR 2ND FLOOR AND 3RD FLOOR COLLEGE TO BUSINESS OFFICE AND ROOF TERRACE . UPON INSPECTION WAS NOTED SITE CLOSED, RESEARCH IN BIS AND DOB NOW PERMITS B00337339, B00684113,B #39516388X | Jan 4, 2024 IN VIOLATION | $1,250 |
| Jan 10, 2023 | Construction CLASS - 2 SIDEWALK SHED LIGHTING BC 3307.6.4.8. ON 3 STORY ALT1 ENLARGEMENT SITE OBSERVE SIDEWALK SHEDS ELECTRIC LIGHT FIXTURES IN PLACE AND UNLIT FOR UNDERSIDE PEDESTRIAN PASSAGEWAY DURING NO DAYLIGHT (6AM) CONTRARY TO #39511443R | May 10, 2023 IN VIOLATION | $2,400 |
| Jan 10, 2023 | Construction CLASS - 2 AT TIME OF INSPECTION OF INACTIVE CONSTRUCTION ON A 3 STORY BUILDING I OBSERVED NO COMPLIANCE IN REGARD TO PREVIOUS ISSUED VIOLATION 39508392Z ISSUED ON 10/28/2022 FOR UNGUARDED HOLES ON 3RD FLOOR AND ROOF LEVE #39511446M | Aug 7, 2023 IN VIOLATION | $1,250 |
| Oct 28, 2022 | Construction CLASS - 1 OBSERVED : ACTIVE SITE UNDER PERMIT #322020077 UPON INSPECTION WAS IDENTIFIED FOLLOWING UNSAFETY CONDITION : UNPROTECTED HOLE OPENINGS ON 3RD FLOOR LEVEL AND ROOF LEVEL TERRACE , SEVERAL HOLES 3 BY 3 AND 4 BY 3 #39508392Z | Aug 7, 2023 IN VIOLATION | $2,500 |
| Oct 28, 2022 | Construction CLASS - 2 INADEQUATE ROOF PROTECTION : OBSERVED ON ROOF AC UNITS AND SKYLINE NOT FULLY COVERED , LEADING EDGE NOT PROTECTED ., NO GUARD RAILS , CREATING HAZARDS FOR WORKERS ON SITE PROVIDE ADEQUATE ROOF PROTECTION / STOP #39508385K | Aug 7, 2023 IN VIOLATION | $625 |
| Oct 28, 2022 | Construction CLASS - 1 SUPPORTED SCAFFOLD NOT MAINTAINED PER CODE .OBSERVED IN DIFERENTS LOCATION MISSING TOE BOARDS ON EXPOSURE 1 3RD FLOOR LEVEL , SCREW JACKS AND INADEQUATE BRACING AT REAR PART OF BUILDING ON TERRACE PROVIDE ADE #39508384Z | Aug 7, 2023 IN VIOLATION | $625 |
| Jun 3, 2021 | Construction CLASS - 2 SEC. 3307.6.4.8 SIDEWALK SHED LIGHTING. NOTE: AT TIME OF MY INSPECTIONOF A 3 STY BLDG NO WORK IN PROGRESS. I OBSERVED AT 5:00AM THAT THE LIGHTS UNDER THE SIDEWALK SHED WAS NOT LIT. THE FIXTURES WERE PRESENT WIT #35558811Y | Aug 15, 2022 IN VIOLATION | $1,250 |
| Mar 15, 2021 | Site Safety CLASS - 1 FAILURE TO DESIGNATE &/OR HAVE CONST SUPER PRESENT@SITE AS REQUIRED NOTE:@TIME OF MY INSP OF 4STYBLDG UNDER VERT ENLARGEMENT ALT WORK,UPON REV DEPT RECORDS FOUND THAT THERES NO CONST SUPER DESIGNATED FOR JOB,CR #35544043N | Jul 28, 2021 DEFAULT | $12,500 |
| Jul 10, 2019 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION#35344096K ISSUED ON 08/24/18,AND TO FILE A CERTIFICATE OF PURSUANT TO 28-201.1 AND 1RNCY 102-01(D)(2).AN ACCEPTIBLE CERTIFICATE HAS #37015368K | Dec 9, 2019 DEFAULT | $3,125 |
| Issued | Violation | Status |
|---|---|---|
| Mar 15, 2021 | CONSTRUCTION #E0202MG | DOB VIOLATION - ACTIVE |
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #28259 | DOB VIOLATION - ACTIVE |
| Mar 9, 1989 | ELEVATOR (51)CEASE USE OF ESCALATOR UNTIL THE MAIN MACHINE IS REPAIRED, WORN DRIVE GEAR ON UPPER CARRIAGE IS REPLACED #1448D-02 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 29, 2026 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Active |
| Oct 29, 2026 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Active |
| Oct 29, 2026 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Active |
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| Sep 18, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle B (premises is in Community District 2) | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Open |
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Open |
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Open |
| Oct 21, 2026 | ECB | Construction: FAILURE TO MAINTAIN, I OBSERVED HVAC UNIT ON ROOF LEAKING WATER ONTO ROOF FLOOR. AS PER PC 102.3 BOTH NEW AND EXISTING INSTALLATIONS SHALL BE MAINTAINED IN PROPER OPERATING CONDITION., REPAIR AND/OR REPLACE | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 1, 2026, 3:15 PM ET. BBL 3001460053.