3 floors · 6 apartments · 4,368 sq ft · built 1905 · class C2 · owner of record: Madimenos, George
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 66 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 82 days | Annual |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1162 days | Next cycle year 2029 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-13 (Accepted). Agency page | On file | 2026 reports accepted |
None open.
None open.
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Aug 19, 2026 | C | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES AT PUBLIC HALL, 1st STORY | Aug 25, 2026 |
| Jun 8, 2026 | B | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT PUBLIC HALL STAIRS, 3rd STORY | Jul 13, 2026 |
| Jun 8, 2026 | A | Apt 2R · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL STOPPER AT BATHTUB IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | Sep 11, 2026 |
| Jun 8, 2026 | B | Apt 2R · 28 RCNY § 25-171; & 67 (7)(B) MDL; NYC FIRE CODE § 703.1.3; NYC FIRE CODE § 703.2: ADJUST DOOR TO PREVENT GAPS BETWEEN THE TOP AND SIDE EDGES OF DOOR AND DOOR JAMB EXCEEDING THE MAXIMUM ALLOWABLE CLEARANCE OF 1/8 OF AN INCH AND MAXIMUM ALLOWABLE CLEARANCE OF 3/4 OF AN INCH BETWEEN THE DOOR BOTTOM AN | Jul 13, 2026 |
| Jun 8, 2026 | B | Apt 2R · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | Jul 13, 2026 |
| Jun 8, 2026 | B | Apt 2R · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | Jul 13, 2026 |
| Jun 8, 2026 | C | Apt 2R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | Jul 4, 2026 |
| Jun 8, 2026 | C | Apt 2R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | Jul 4, 2026 |
| Jun 8, 2026 | B | Apt 2R · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | Jul 13, 2026 |
| Jun 8, 2026 | A | Apt 2R · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING IN THE FOYER LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | Sep 11, 2026 |
| Jun 8, 2026 | B | Apt 2R · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE UPPER SASH GLASS PANE AT WINDOW AT EAST IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | Jul 13, 2026 |
| Jun 8, 2026 | B | Apt 2R · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL AIR VENT AT CEILING IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | Jul 13, 2026 |
| Jun 8, 2026 | A | Apt 2R · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING IN THE 6th ROOM FROM NORTH LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | Sep 11, 2026 |
| Jun 8, 2026 | B | Apt 2R · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ALL ELECTRICAL OUTLETS AT WEST WALL IN THE 6th ROOM FROM NORTH LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | Jul 13, 2026 |
| Jun 8, 2026 | B | Apt 2R · 28 RCNY § 25-171; & 67 (7)(B) MDL; NYC FIRE CODE § 703.1.3; NYC FIRE CODE § 703.2: ADJUST DOOR TO PREVENT GAPS BETWEEN THE TOP AND SIDE EDGES OF DOOR AND DOOR JAMB EXCEEDING THE MAXIMUM ALLOWABLE CLEARANCE OF 1/8 OF AN INCH AND MAXIMUM ALLOWABLE CLEARANCE OF 3/4 OF AN INCH BETWEEN THE DOOR BOTTOM AN | Jul 13, 2026 |
| Jun 8, 2026 | A | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE MASONRY STUCCO AT SOUTH EXTERIOR WALL AT 3RD STORY | Sep 11, 2026 |
| Jun 8, 2026 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILE AT PUBLIC HALL, 1st STORY | Jul 13, 2026 |
| Jun 8, 2026 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING AT PUBLIC HALL, 1st STORY | Sep 11, 2026 |
| Jun 8, 2026 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING AT PUBLIC HALL, 2nd STORY | Sep 11, 2026 |
| Jun 8, 2026 | B | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT PUBLIC HALL, 2nd STORY | Jul 13, 2026 |
| Jun 8, 2026 | B | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING AT PUBLIC HALL, 3rd STORY | Jul 13, 2026 |
| Jun 8, 2026 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING AT PUBLIC HALL, 3rd STORY | Sep 11, 2026 |
| Jun 8, 2026 | B | 28 RCNY § 25-171; & 67 (7)(B) MDL; NYC FIRE CODE § 703.1.3; NYC FIRE CODE § 703.2: ADJUST DOOR TO PREVENT GAPS BETWEEN THE TOP AND SIDE EDGES OF DOOR AND DOOR JAMB EXCEEDING THE MAXIMUM ALLOWABLE CLEARANCE OF 1/8 OF AN INCH AND MAXIMUM ALLOWABLE CLEARANCE OF 3/4 OF AN INCH BETWEEN THE DOOR BOTTOM AN | Jul 13, 2026 |
| Jun 8, 2026 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING AT PUBLIC HALL STAIRS, 2nd STORY | Sep 11, 2026 |
| Jun 8, 2026 | C | Apt 2R · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | Jun 14, 2026 |
| Jun 8, 2026 | C | Apt 2R · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWER SASH COUNTER BALANCE AT 2ND WINDOW FROM EAST AT SOUTH IN THE 6th ROOM FROM NORTH LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | Jun 14, 2026 |
| Jun 8, 2026 | C | Apt 2R · § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRING AT CEILING IN THE 6th ROOM FROM NORTH LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | Jun 14, 2026 |
| Jun 8, 2026 | A | Apt 2R · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE REGLAZE ENAMEL PORCELAIN AT BATHTUB IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | Sep 11, 2026 |
| Jun 8, 2026 | C | Apt 2R · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 30 SQ FT AT EAST WALL IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | Jul 4, 2026 |
| Jun 8, 2026 | B | Apt 2R · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE WASHBASIN IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | Jul 13, 2026 |
| Jun 8, 2026 | B | Apt 2R · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR IN THE KITCHEN LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | Jul 13, 2026 |
| Jun 8, 2026 | B | Apt 2R · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | Jul 13, 2026 |
| Jun 1, 2026 | B | Apt 2R · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASHBASIN IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST | Jul 6, 2026 |
| Jun 1, 2026 | B | Apt 2R · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL VENT AT CEILING IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST | Jul 6, 2026 |
| Jun 1, 2026 | B | Apt 2R · § 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET FILL VALVE IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST | Jul 6, 2026 |
| Jun 1, 2026 | B | Apt 2R · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE OUTLET AT NORTH WALL IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST | Jul 6, 2026 |
| Jun 1, 2026 | B | Apt 2R · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE OUTLET SOUTH WALL IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST | Jul 6, 2026 |
| Jun 1, 2026 | B | Apt 2R · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 30 SQ FEET AT CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST | Jul 6, 2026 |
| Jun 1, 2026 | B | Apt 2R · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SLOPING WOOD FLOOR IN THE KITCHEN LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST | Jul 6, 2026 |
| Jun 1, 2026 | C | Apt 2R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST | Jun 27, 2026 |
| Jun 1, 2026 | C | Apt 2R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST | Jun 27, 2026 |
| Jun 1, 2026 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES AT PUBLIC HALL, 1st STORY | Jul 6, 2026 |
| Jun 1, 2026 | C | Apt 2R · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST | Jun 15, 2026 |
| Jun 1, 2026 | A | Apt 2R · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT NORTH WALL IN THE ENTRANCE LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST | Sep 4, 2026 |
| Jun 1, 2026 | B | Apt 2R · § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED WIRING AT CEILING IN THE 6th ROOM FROM EAST LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST | Jul 6, 2026 |
| Jun 1, 2026 | B | Apt 2R · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING LIGHT FIXTURE AT CEILING IN THE 6th ROOM FROM EAST LOCATED AT APT 2R, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST | Jul 6, 2026 |
| May 19, 2008 | C | Apt 2R · SECTION 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY ?11-06(B)(2) NORTH WALL, SOUTH WALL, WEST WALL IN THE KITCHEN LOCATED AT APT 2R, 2nd STORY, 2 | Jun 14, 2008 |
| Date | Source | What | Now |
|---|---|---|---|
| Aug 19, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT BUILDING ENTRANCE DOOR | Closed |
| Aug 19, 2026 | HPD C | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES AT PUBLIC HALL, 1st STORY | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 26, 2026, 7:28 PM ET. BBL 3007750075.