5 floors · 6 apartments · 5,820 sq ft · built 1920 · class S9 · owner of record: 52 West 55th Street,Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 49 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 49 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-05-27 (Accepted). Agency page | Dec 31, 2026 in 49 days | 1 of 1 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 65 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 293 days | Registered through 2027-09-01 |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1145 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 25, 2015 | Unknown CLASS - 2 ELECTRICAL WORK W/O PERMIT.OBSERVED @ 10AM OUTLETS INSTALLED IN ALL HALLWAYS.NO APPLICATION ON FILE FOR ELECTRICAL OUTLETS.REM OBTAIN PERMIT #35123574R | Sep 10, 2015 STIPULATION/IN-VIO | $0 |
| Jan 19, 2006 | Construction Non-Hazardous FAILURE TO MAINTAIN. DEFECT IS: EXTERIOR WALL (BRICK) HAS CRACK ABOVE WINDOW AT APT 5R (5TH FL). (2) PLASTER MISSING AROUND GUTTER (3) MORTAR JOINT MISSING IN VARIOUS LOCATION. REMEDY: REPAIR ALL DEFECTS. #34505539Z | Mar 9, 2006 STIPULATION/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Mar 19, 2003 | LOCAL LAW 62/91 - BOILERS #03739 | DOB VIOLATION - ACTIVE |
| Sep 15, 2000 | CONSTRUCTION #ZSTF02YC | DOB VIOLATION - ACTIVE |
| Dec 8, 1995 | CONSTRUCTION #05C02 | VIOLATION WORK WITHOUT PERMIT - ACTIVE |
| Nov 14, 1989 | BOILER 31A/32 AQUISTAT COVER MISSING-DIRTY BOILER ROOM/SOOT #32003570Y | VIOLATION UNSERVED ECB-ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Mar 19, 2003 | Boiler LL6291 | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 12, 2026, 3:02 AM ET. BBL 1012700062.