3 floors · 3 apartments · 2,664 sq ft · built 1899 · class C0 · owner of record: Saint Felix Organization Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 43 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 43 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 59 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1139 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jun 14, 2025 | Construction CLASS - 2 AT TIME OF INSPECTION, I OBSERVED NO VIEWING PANEL INSTALL TO JOB SITE FENCE AT EXPOSURE #1. #39541434M | Aug 20, 2025 DEFAULT | $5,000 |
| Mar 14, 2025 | Construction CLASS - 1 OBSERVED SITE HAS REMOVE REAR WALL AT GROUND LEVEL AT EXP 3 WHILE UNDER A PSWO THAT WAS ISSUED ON 12/10/24 UNDER COMPLIANT #3987160 VIO# 39535048N. PARTIAL RESCIND WAS ISSUED AND ALLOWED ONLY TO DO HOUSEKEEPING #39538006Z | May 21, 2025 DEFAULT | $25,000 |
| Mar 13, 2025 | Construction CLASS - 1 AT REAR OF BUILDING,MASONRY WALL IN A STATE OF DISREPAIR WITH MISSING MASONRY AND INADEQUATE SHORING AND STABILITY., MAINTAIN EXTERIOR BUILDING WALL #39141449M | May 21, 2025 DEFAULT | $25,000 |
| Dec 10, 2024 | Construction CLASS - 1 3 STORY BUILDING UNDER GOING RENOVATION OBSERVED SISTERING OF WOOD JOIST AT SEVERAL LOCATIONS THROUGHOUT THE BUILDING. NO INDICATION ON APPROVE DOCUMENTS PROVIDED AT TIME OF INSPECTION. STOP ALL WORK UNDER JOB #39535048N | Feb 19, 2025 DEFAULT | $12,500 |
| Jul 19, 2023 | Construction CLASS - 1 A VIOLATION & PSWO WAS ISSUED & POSTED ON 07-16-23 FOR WWP IN THE GUT RENOVATION ON THE INTERIOR OF THE BUILDING, ATI SEVERAL WORKERS WERE OBSERVED WORKING ON THE PROPERTY CONTINUING IN THE GUT RENOVATION WHILE #39090516X | Mar 11, 2027 PENDING | $25,000 |
| Jul 17, 2023 | Construction CLASS - 1 WORK WITH OUT A PERMIT, WORK NOTED THE BUILDING INTERIOR GUT RENOVATION. NEW BRICK WORK ALONG EXPOSURE 2 WALL. NEW METAL STUD FRAMING, THE REAR WALL IS OPEN., OBTAIN PERMIT #39090397M | Jul 20, 2026 IN VIOLATION | $2,500 |
| Oct 15, 2022 | Construction CLASS - 2 AT TIME OF INSPECTION OF 3 STORY BUILDING OBSERVED SWS IN PLACE AT EXP #1 MISSING PARAPET PANELS AT EXPO#-1-4.AND (MUDSILLS) EXP #1 ROTTEN MUDSILLS UNDER SUPPORTING SHORING POSTS CREATING UNSAFE CONDITION FOR #39507641X | Feb 15, 2023 DEFAULT | $5,000 |
| Oct 15, 2022 | Construction CLASS - 2 AT THE TIME OF INSPECTION OBSERVED SIDE WALK SHED , PERMIT FOR SHED EXPIRED ON 09/04/2014 RENEW PERMIT MAINT SHED COMPLY AS PER CODERENEW PERMIT MAINT SHED COMPLY AS PER CODE #39507642H | Feb 15, 2023 DEFAULT | $5,000 |
| Oct 15, 2022 | Construction CLASS - 2 AT TIME OF INSPECTION OF 3 STORY BUILDING OBSERVED SWS IN PLACE AT EXP #1 AT 5:00AM NO LIGHT UNDER THE SIDEWALK SHED CREATING UNSAFE CONDITION FOR PEDESTRIAN COMPLY WITH CODE #39507643J | Feb 15, 2023 DEFAULT | $5,000 |
| Oct 14, 2022 | Construction CLASS - 2 28-104.2.2 EXPIRED PERMIT ATOI OBSERVED SIDEWALKSHED PERMIT HAS BEEN EXPIRED ON9/4/14.SWS REMAIN ON PLACE RENEW/OBTAIN PERMIT #35593198Z | Mar 15, 2023 DEFAULT | $3,125 |
| Oct 14, 2022 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODECOMPLIANT MANNER.ATOI OBSERVED@EXP1 SIDEWALKSHED IN DISREPAIR CONDITION PANEL MISSING PARTS FALLING ROTTEN SUPPORTED MUDSILLS DEBRIS FROM THIS SCF FALLING TO PEDESTRIAN SW&ADJ PR #35593197R | Mar 15, 2023 DEFAULT | $3,125 |
| May 16, 2022 | Construction CLASS - 2 SIDEWALK SHED DOES NOT MEET CODE SPECIFICATION.NOTE:AT TIME OF INSPECTION OF 3 STORY BUILDING OBSERVED SWS IN PLACE AT EXP #1 PARAPET PANELS IN DANGER OF FALLING,MISSING PARAPET PANELS,MISSING 'CATCHALL' EXTENS #35654551R | Oct 12, 2022 DEFAULT | $5,000 |
| May 16, 2022 | Construction CLASS - 2 TEMPORARY CONSTRUCTION EQUIPMENT ON SITE-EXPIRED PERMIT.NOTE:AT TIME OF INSPECTION OF 3 STORY BUILDING OBSERVED AT EXP #1 SIDEWAKL SHED IN PLACE SEARCHED BIS SWS PERMIT EXPIRED.FAILUE TO RENEW PERMIT AS PER COD #35654550P | Oct 12, 2022 DEFAULT | $3,125 |
| May 5, 2022 | Construction CLASS - 2 AT THE TIME OF INSPECTION OBSERVED SIDE WALK SHED HAS PARAPAT PANELS LEANING OUTSIDE WHICH CAUSING UNSAFE CONDITION TO THE PUBLIC, PERMIT FOR SHED EXPIRED ON 09/04/2014RENEW PERMIT MAINT SHED COMPLY AS PER CODE #39501158Z | Sep 7, 2022 | $1,250 |
| Dec 1, 2021 | Unknown CLASS - 2 FAILURE TO OBTAIN TEMPORARY CONSTRUCTION PERMIT PRIOR TO INSTALLATION /USE OF TEMPORARY CONSTRUCTION EQUIPMENT(SIDEWALK SHED)NOTE:INSPECTION OF 3 STORY BUILDING NO ACTIVE CONSTRUCTION WORK OBSERVED SWS IN PLACE #35504929X | Apr 13, 2022 DEFAULT | $3,125 |
| Dec 1, 2021 | Construction CLASS - 2 PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS(MUDSILLS)NOTE:INSPECTION OF 3 STORY BUILDING NO ACTIVE CONSTRUCTION WORK OBSERVED USAFE SIDEWALK SHED AT EXP #1 ROTTEN MUDSILLS UNDER SUPPORTING SHORING P #35504930N | Apr 13, 2022 DEFAULT | $5,000 |
| Dec 1, 2021 | Construction CLASS - 1 BC3307.6.3 PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS(5' EXTENSION FOR ADJACENT BUILDING)NOTE:INSPECTION OF 3 STORY BUILDING NO ACTIVE CONSTRUCTION WORK OBSERVED SIDEWALK SHED AT EXP #1 DOES NOT ME #35504931P | Apr 13, 2022 DEFAULT | $12,500 |
| Dec 1, 2021 | Construction CLASS - 1 BC3307.6.4.6 FAILURE TO MAINTAIN PARAPET WALL FOR SIDEWALK SHED.NOTE: INSPECTION OF 3 STORY BUILDING NO ACTIVE CONSTRUCTION WORK OBSERVED SWS AT EXP #1 UNSAFE AS PARAPET WALL IS LOOSE AND LEANING TOWARDS STREET #35504932R | Apr 13, 2022 DEFAULT | $12,500 |
| Sep 2, 2021 | Construction CLASS - 2 TEMPORARY CONSTRUCTION EQUIPMENT ON SITE EXPIRED PERMIT. NOTE: AT TIMEOF MY INSPECTION OF A 3 STY OCCUPIED BLDG NO WORK IN PROGRESS,I OBSERVED THAT THE SIDEWALK SHED PERMIT EXPIRED AFTER I MADE A REVIEW OF DEPT #35590901H | Jan 12, 2022 DEFAULT | $5,000 |
| Sep 2, 2021 | Construction CLASS - 2 PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. NOTE: AT TIMEOF MY INSPECTION,I OBSERVED THAT THE SIDEWALK SHED. IN FRONT OF A 3 STY OCCUPIED BLDG WAS IN POOR CONDITION. THE MUDSILLS WERE ROTTED PIECES #35590900X | Jan 12, 2022 DEFAULT | $5,000 |
| May 11, 2021 | Construction CLASS - 2 PEDESTRIAN PROTECTION DOESNT MEET CODE SPECS NOTE:@TIME OF MY INSP OF 3STY OCCUPIED BLDG I OBSERVED ERECTED SWS ON EXP1 IN POOR CONDITION,MUDSILLS ROTTING OUT,PARAPET WALLS LEANING AWAY FROM SWS,ENTIRE SWS GIVE #35558881J | Sep 22, 2021 DEFAULT | $5,000 |
| May 11, 2021 | Construction CLASS - 2 TEMP CONST EQUIPMENT ONSITE EXPIRED PERMIT NOTE:@TIME OF MY INSP OF 3STY OCCUPIED BLDG W/ERECTED SWS@EXP1.UPON REV OF DEPT RECORDS IT REVEALED THERES NO ACTIVE PERMIT FOR SWS ERECTED ON EXP1.RENEW PERMIT. #35558880H | Sep 22, 2021 DEFAULT | $5,000 |
| Dec 31, 2020 | Construction CLASS - 2 TEMPORARY CONSTRUCTION EQUIPMENT ON SITE EXPIRED PERMIT. NOTE: AT TIMEOF MY INSPECTION OF A SIDEWALK SHED IN FRONT OF BLDG. NO WORK IN PROGRESS,I RESEARCHED DEPTS RECORDS & DISCOVERED THAT THE SODEWALK SHED PER #35509205N | May 12, 2021 DEFAULT | $3,125 |
| Dec 31, 2020 | Construction CLASS - 2 PEDESTTRTIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. NOTE: AT TIME OF MY INSPECTION,I OBSERVED THAT THE SIDEWALK SHED LOCATED AT EXP#1IN FRONT OF A 3 STY BLDG WAS NOT MAINTAINED THE PARAPET PANEL AT EXP#1 #35509204L | May 12, 2021 DEFAULT | $5,000 |
| Aug 6, 2019 | Construction CLASS - 2 SIDEWALK SHED DOES NOT MEET CODE SPECIFICATION. AT THE TIME OF MY INSPECTION: I OBSERVED THE SIDEWALK SHED WAS NOT MAINTAINED. THREE MUDSILLS WAS NOT MAINTAINED AS PER XODE AT EXP#1. MUDSILLS WAS ROTTEN OUT. #35438756Y | Dec 9, 2019 DEFAULT | $5,000 |
| Aug 6, 2019 | Unknown CLASS - 2 FAILURE TO OBTAIN A TEMPORARY CONSTRUCTION PERMIT PRIOR TO INSTALLATION/USE OF SIDEWALK SHED. AT TIME OF MY INSPECTION ON A 3 STY BLDG I OBSERVED THE SIDEWALK SHED IN PLACE W/NO PERMIT ON FILE AFTER CHECKING #35438754K | Dec 9, 2019 DEFAULT | $6,250 |
| May 9, 2019 | Construction CLASS - 2 TEMPORARY CONSTRUCTION EQUIPMENT ON SITE-EXP PERMIT. AT TIME OF INSPECTION RESPONDING TO A COMPLAINT#3699476 FOR SIDEWALK SHED NOTED AFTER REVIEW ON BIS SYSTEM SH#320785780-01 HAS EXP 9-4-14 & THE OWNER HAS FAI #35418490H | Aug 19, 2019 DEFAULT | $3,125 |
| May 9, 2019 | Construction CLASS - 2 SIDEWALK SHED DOES NOT MEET CODE SPECIFICATION FAILURE TO MAINTAIN. ATTIME OF INSPECTION,I OBSERVED SIDEWALK SHED WAS NOT PAINTED HUNTER GREEN,MISSING PARTITION OF PARAPET & MUDSILL ARE(BROKER),THIS CREATING #35418489K | Aug 19, 2019 DEFAULT | $5,000 |
| Jul 3, 2013 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES. NOTED: 3 STORY BROWNSTONE AT EXPOSURE 1 (FACADE) STUCCO FINISH HAS CRACKS & PARTS OF WALL HAVE DETACHED & FALLEN. AT 3RD FL ORNAMENTAL STONE ABOVE WINDOW HAS #35022166P | Aug 19, 2013 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Mar 13, 2025 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED REAR MASONRY WALL IN A STATE OF DISREPAIR. MASONRY MISSING AND TEMPORARY SHORING INADEQUATE. WALL APPEARS TO BE SETTLING AND SEPARATING ABOVE 1ST FLOOR WINDOW. #25-00453 | DOB VIOLATION - ACTIVE |
| Oct 14, 2022 | IMMEDIATE EMERGENCY REPAIR SIDEWALK SHED IN ORDER TO SAFEGUARD THE PUBLIC AND PROPERTY #17215 | DOB VIOLATION - ACTIVE |
| Mar 2, 2022 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00293 | DOB VIOLATION - ACTIVE |
| Mar 2, 2022 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00294 | DOB VIOLATION - ACTIVE |
| Sep 25, 2013 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00137 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 18, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle B (premises is in Community District 2) | Active |
| Mar 2, 2022 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 2, 2022 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 25, 2013 | AEUHAZ FTC-AEU-HAZ | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Sep 8, 2009 | B | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE LOOSE AND CRACK VERTICAL EXTERIOR MASONARY FRAME CASING AT 3RD STY AT FRONT AREAWAY | Oct 13, 2009 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 18, 2026, 1:47 AM ET. BBL 3020960055.