Brooklyn · Block 198 · Lot 34 · 11217

52 4th Avenue

9 floors · 74,014 sq ft · built 2023 · class D7 · owner of record: 52 4th Ave Holdings Llc

0open violations
$56,875ECB/OATH penalties owed
0HPD class C (immediately hazardous)
188dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 67 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 74,014 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 188 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 188 days
Annual filing
Facade inspection report (Cycle 10B) Applies
Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. Agency page

Feb 21, 2028
in 484 days
No Cycle 10 report on record yet
Energy audit and retro-commissioning (2028) Likely applies
Local Law 87 · Calendar year 2028
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 198). Agency page

Dec 31, 2028
in 798 days
Next due 2028
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1163 days
Next cycle year 2029

Open violations

ECB / OATH (16) · $56,875 owed
IssuedViolationHearingBalance
Nov 6, 2025Construction CLASS - 2
AT TIME OF INSPECTION, OBSERVED ACTIVE STUCCO OPERATIONS ON SUSPENDED AND SUPPORTED SCAFFOLDS WITH RESIDUE AND DEBRIS FALLING TO SIDEWALK, STREET, AND AIRBORNE. CONTRARY TO BC 3301.2. UNCONTROLLED DISCHARGE CRE
#39546729M
Apr 9, 2027
$5,000
Nov 6, 2025Construction CLASS - 2
AT TIME OF INSPECTION, OBSERVED WORKERS USING A-FRAME LADDERS NOT FULLY OPENED AND USED CONTRARY TO MANUFACTURER SPECIFICATIONS. CONTRARY TO BC 3301.6.1, PERMIT HOLDER FAILED TO ENSURE EQUIPMENT WAS UTILIZED PE
#39546730J
Apr 9, 2027
$1,250
Nov 6, 2025Construction CLASS - 1
AT TIME OF INSPECTION, OBSERVED STAIRS WITHOUT REQUIRED HANDRAILS USED FOR ACCESS WITHIN ACTIVE WORK AREA. CONTRARY TO BC 3301.2. MISSING HANDRAILS CREATE SLIP AND FALL HAZARD TO WORKERS AND PUBLIC.PROVIDE HAND
#39546728K
Apr 9, 2027
$2,500
Sep 30, 2025Unknown CLASS - 1
AT TIME OF INSPECTION AN INADEQUATE PRE SHIFT MEETING LOG WAS OBSERVED. UNABLE TO DETERMINE WHAT TASKS WERE DISCUSSED FOR THE DAY. THIS CREATES UNSAFE CONDITIONS BY NOT DELEGATING SITE SPECIFIC TASKS AND REQUIR
#39545482P
Jan 7, 2027
$5,000
Sep 30, 2025Construction CLASS - 1
RESPONDED TO WORKER FELL OFF OF A LADDER & TRANSPORTED OFF SITE BY EMT, GC FAILED TO ENSURE SAFE LADDER USE TO SPECS AND SAFETY STANDARDS IN RESPONSE TO INCIDENT WHERE WORKER WAS PERFORMING OVERHEAD SEALANT WOR
#39545483R
Jan 7, 2027
$2,500
Sep 17, 2025Unknown CLASS - 1
3314.1 AT THE TIME OF MY INSPECTION OF A 12-STORY ACTIVE JOB SITE, I OBSERVED PIPE SCAFFOLDS AT EXPOSURES 1, 2, 3, AND 4 NOT PROPERLY MAINTAINED, WITH MULTIPLE MISSING PINS AND STEP LADDERS NOT ANCHORED. THIS C
#39545034L
Mar 25, 2027
$5,000
Sep 17, 2025Construction CLASS - 1
AT THE TIME OF MY INSPECTION OF A 12-STORY NEW BUILDING ACTIVE JOB SITE, I OBSERVED THAT AT THE FIRST-FLOOR LEVEL, STAIRS LEADING TO THE CELLAR LACK A HANDRAIL. THIS CONDITION POSES A HAZARD AND DANGER TO WORKE
#39545035N
Mar 25, 2027
$2,500
Sep 13, 2025Unknown CLASS - 2
BC 3303.3 WATCH PERSON. INSPECTION REVEAL A 12 STORY NEW BUILDING UNDER CONSTRUCTION WITH FOOT PRINT OF 7,283 SQUARE FEET OF WORK COVERAGE UPON LOUD SHOUTING AND BANGING AT JOB SITE FENCE TO ALERT WATCH PERS
#39544858J
Jul 10, 2026
IN VIOLATION
$2,500
Sep 13, 2025Cranes and Derricks CLASS - 2
AT THE TIME OF INSPECTION I OBSERVED SUSPENDED SCAFFOLDING INSTALLED ON SITE AT EXPOSURES 2 AND 3 WAS NOT PROVIDED WITH NOTIFICATION AND SUPPORT METHODS CREATING AN UNSAFE INSTALLATION AND REMOVAL CONDITION.STO
#39544854M
Mar 16, 2027
$2,500
Sep 13, 2025Unknown CLASS - 2
BC 3314.10.11 SECURING SUSPENDED SCAFFOLDING. AT THE TIME OF INSPECTION I OBSERVED SUSPENDED SCAFFOLD WAS NOT LOWERED TO ROOF, SIDEWALK SHED DECK OR GRADE AS REQUIRE BY CODE AND THERE WERE NO INDICATION ON
#39544853K
Mar 16, 2027
$2,500
Sep 9, 2025Unknown CLASS - 2
BC3314.8.2 AT TIME OF INSPECTION OBSERVED SUPPORTED SCAFFOLD INSTALLED, AT EXP# 3 DEBRIS NETTING NOT SECURELY TIED TO FACADE STOP ALL EXTERIOR FACADE WORK AND USED OF SUPPORTED SCAFFOLD MAINTAINED SUPPORTED SCA
#39544659R
Jan 7, 2027
$2,500
Sep 9, 2025Construction CLASS - 2
FOLLOWING UP ON A COMPLAINT WORKER PERFORMING EXTERIOR WORK I OBSERVED STYROFOAM PARTICLES AT VARIOUS LOCATION ROADWAY ADJACENT PROPERTY YARDS, PEDESTRIAN SIDEWALK, WATER DRAINS . FAILURE TO ADEQUATELY CONTAIN
#39544658P
Jan 7, 2027
$5,000
Jul 19, 2025Unknown CLASS - 1
BC3303.81 NB UNDER CONSTRUCTION AT APPROX. 100 FEET IN HEIGHT. I OBSERVED PRESSURE GAUGE AT EXPOSURE 4 WAS READING ZERO AND AT EXPOSURE 1 (27 PSI). I ALSO OBSERVED THAT ALARM SYSTEM WAS NOT ACTIVATED OR HEARD A
#39542571N
Dec 3, 2026
$5,000
Jul 14, 2025Unknown CLASS - 1
AT THE TIME OF MY INSPECTION OF A 12 STORY NEW BUILDING AT 9 FLOOR DECKING, I OBSERVED AT EXPOSURE #2 AND 3 THAT THERE WERE NO HORIZONTAL SAFETY NETTING INSTALLED, THE 7TH AND 8TH FLOORS WERE STRIPPING. FAILURE
#39542343L
Jan 26, 2027
$5,000
Apr 1, 2025Construction CLASS - 2
POSTING OF UNLAWFUL SIGNS INFORMATION, PICTORIAL REPRESENTATION BUSINESS OR ADVERTISING MORTAGES ON PROTECTIVE STRUCTURES: AS NOTED AT TIME OF INSPECTION OBSERVED SITE FENCE NOT MAINTAINED TO CODE WITH A LOT OF
#35716737X
Jun 11, 2025
DEFAULT
$5,000
Mar 17, 2025Construction CLASS - 2
TEMPORARY CONSTRUCTION EQUIPMENT OR INSTALLATION ON-SITE EXPIRED PERMIT. AS NOTED: AT TIME OF INSPECTION ON A CONSTRUCTION SITE OF A PROPOSED 12 STORY BUILDING WAS CLOSED, OBSERVED CONSTRUCTION FENCE PERMIT HAD
#35689938L
May 28, 2025
DEFAULT
$3,125
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 25, 2026, 10:12 AM ET. BBL 3001980034.