Brooklyn · Block 1739 · Lot 6 · 11206

519 Marcy Avenue

9 floors · 58 apartments · 46,133 sq ft · built 2005 · class D9 · owner of record: Marcy Tower Llc

11open violations
$11,545ECB/OATH penalties owed
0HPD class C (immediately hazardous)
63dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 63 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 63 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 79 days
Annual
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $28,000 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2027
in 115 days
No Cycle 10 report on record yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 46,133 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 184 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 184 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 307 days
Registered through 2027-09-01
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 794 days
Next cycle year 2028

Open violations

ECB / OATH (9) · $11,545 owed
IssuedViolationHearingBalance
Jun 2, 2026Elevators CLASS - 1
CLASS 1: DOOR LOCK MONITORING FEATURE MALFUNCTIONING - CAR SIDE/DOOR CONTACT NOT OPERATING AS REQUIRED AS PER ASME A17.1/CSA B44 2.26.9 AND NYC BC APPENDIX K3. IMMEDIATE HAZARDOUS CONDITION. NO ROOF/MACHINE ROO
#39190730P
Aug 12, 2026
IN VIOLATION
$1,250
Jun 2, 2026Boilers CLASS - 2
APT#9D BOSH BOILER HAS NO CONDENSATE NEUTRALIZER+APT#8B BOILER SAFETY IS NOT PIPED DOWN+APT#7E BOILER RELIEF VALVE NOT PIPED DOWN+APT#7F SHUTOFF VALVE BETWEEN BOILER+SAFETY VALVE+APT#7B CO DETECTOR REMOVED+APT#
#39191237X
Aug 19, 2026
STIPULATION/IN-VIO
$620
Jun 2, 2026Boilers CLASS - 2
APT#2H CO DETECTOR REMOVED+APT#2E SAFETY VALVE LEAKING+NOT PIPED DOWN+APT#1B BOTH SAFETY VALVES+BACKFLOW NOT PIPED DOWN+CO DETECTOR DEFECTIVE+APT#1F RELIEF VALVE NOT PIPED DOWN+CO DETECTOR DEFECTIVE, MAINTAIN B
#39191275R
Aug 19, 2026
STIPULATION/IN-VIO
$620
Jun 2, 2026Boilers CLASS - 2
APT#3A RELIEF VALVE+BACKFLOW NOT PIPED DOWN+APT#3B CO DETECTOR DEFECTIVE+SAFETY VALVE NOT PIPED DOWN+APT#3E NO NEUTRALIZER+BOTH SAFETY VALVES NOT PIPED DOWN+APT#3F NO NEUTRALIZER+SAFETY VALVE NOT PIPED DOWN+APT
#39191268Z
Aug 19, 2026
STIPULATION/IN-VIO
$620
Jun 2, 2026Boilers CLASS - 3
APT#5B NO NEUTRALIZER+RELIEF VALVE NOT PIPED DOWN+APT#5D NO SAFETY DISCHARGE PIPE+APT#5C BACKFLOW NOT PIPED DOWN+APT#5E CO DETECTOR DEFECTIVE+BACKFLOW NOT PIPED DOWN+APT#4A BACKFLOW NOT PIPED DOWN+APT#4D TRI GA
#39191243M
Aug 19, 2026
STIPULATION/IN-VIO
$250
Jul 3, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1.8 (2014 CODE); 27-371; BC 1008.1.9 (2014 CODE); BC 1010.1.8 (2022 CODE); BC 1010.1.9 (2022 CODE). OBSE
#39152772X
Feb 25, 2027
$2,530
Jul 3, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE. OBSERVED HOLE PENETRATIONS, UNPERMITTED PLASTIC ACCESS PANELS. PANELS NOT FIRE RA
#39152773H
Feb 25, 2027
$2,530
Jan 10, 2024Construction CLASS - 1
UNLAWFUL ACTS: FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION# 39078080M ISSUED ON 01/20/23 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01. (UNAPPRO
#39103181N
Jan 13, 2025
IN VIOLATION
$2,500
Jan 20, 2023Construction CLASS - 2
OBSERVED THROUGHOUT BUILDING NO VENTILATION OR GAS DETECTION SYSTEM FOR THE MECHANICAL ROOMS IN THE PUBLIC CORRIDORS. AS PER 701.2 COMBUSTION, VENTILATION, AND DILUTION AIR REQUIRED. EVERY ROOM OR SPACE CONTAIN
#39078062Z
Jun 6, 2024
IN VIOLATION
$625
DOB (1)
IssuedViolationStatus
Feb 22, 2022NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022
#01767
DOB VIOLATION - ACTIVE
DOB NOW Safety (4)
IssuedViolationStatus
Sep 9, 2026AEUHAZ FTC-AEU-HAZ
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction
Active
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
Feb 22, 2022Facades FISPNRF
FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Sep 9, 2026DOB SafetyAEUHAZ: Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 29, 2026, 10:29 AM ET. BBL 3017390006.

Look up another building