Bronx · Block 3059 · Lot 1 · 10458

518 East Fordham Road

4 floors · 101,500 sq ft · built 1926 · class W1 · owner of record: Nyc Department Of Education

63open violations
$3,125ECB/OATH penalties owed
0HPD class C (immediately hazardous)
56dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 56 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 56 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 101,500 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 177 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 177 days
Annual filing
Energy audit and retro-commissioning (2029) Likely applies
Local Law 87 · Calendar year 2029
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 3059). Agency page

Dec 31, 2029
in 1152 days
Next due 2029
Annual boiler inspection (3 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-27 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (38) · $3,125 owed
IssuedViolationHearingBalance
May 13, 2026Construction CLASS - 2
REISSUE#35721599N FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.ILLUMINATION FOR EXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27-381.NOTED:EMERGENCY LIGHTS THROUGHOUT BUILDING DO NOT WORK WH
#35732986R
Jul 10, 2026
POP/IN-VIO
$0
May 13, 2026Construction CLASS - 2
REISSUE#35721377H FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:AT BOILER ROOM,STEEL BEAM IS EXPOSED DUE TO CRACKS IN CEILING,ALSO IN GAS METER ROOM.REM:REPAIR AND/OR REPLACE.
#35732983L
Jul 10, 2026
POP/IN-VIO
$0
May 13, 2026Construction CLASS - 2
REISSUE#35721598L FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:INTERIOR FPSC DOORS DO NOT SELF-CLOSE PROPERLY WHEN TESTED AT 5TH FLR-STAIRCASE 16.CLASSROOM DOORS DO NOT SELF-CLOSE PROPERLY AT 5TH
#35732982J
Jul 10, 2026
POP/IN-VIO
$0
May 13, 2026Construction CLASS - 2
REISSUE#35721376X EMERGENCY SIGNS AT ELEVATOR CALL STATIONS MISSING,DEFECTIVE OR NON-COMPLIANT WITH SECTION REQUIREMENTS.NOTED:1ST FLOOR ELEVATOR A WAS MISSING EMERGENCY SIGN WITH EGRESS PLAN.REM:INSTALL AND/OR
#35732984N
Jul 10, 2026
POP/IN-VIO
$0
May 13, 2026Construction CLASS - 2
REISSUE#35721375Y FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:WIRE MESH GLASS PANELS MISSING IN VARIOUS AREAS IN ALL STAIRCASES,APPROX.40 PIECES MISSING.REM:REPAIR AND/OR REPLACE.
#35732985P
Jul 10, 2026
POP/IN-VIO
$0
Aug 5, 2025Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED AT BOILERROOM, STEEL BEAM CONCRETE CASING, CRACKED AND DETACHING ABOVE DOMESTICGAS METER. REMEDY: REPAIR AND/OR REPLACE.
#35721377H
Aug 29, 2025
POP/IN-VIO
$0
Aug 5, 2025Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. INTERIOR FPSC NOT CLOSING PROPERLY AT: 4TH FL STAIR E, 3RD FL STAIR M, C, E, SMOKE DOORS BY 338 AND 312. 2ND FL STAIR M. 1ST FL SMOKE DOORS BY GYM, BY 112
#35721598L
Aug 29, 2025
POP/IN-VIO
$0
Aug 5, 2025Construction CLASS - 2
REISSUE #35692230N. EMERGENCY SIGNS AT ELEVATOR CALL STATIONS MISSING,DEFECTIVE OR NON-COMPLIANT WITH SECTION REQUIREMENTS. NOTED 1ST FL ELEVATOR "A" WAS MISSING EMERGENCY SIGN WITH EGRESS PLAN. REMEDY: INSTALL
#35721376X
Aug 29, 2025
POP/IN-VIO
$0
Aug 5, 2025Construction CLASS - 2
REISSUE #35692227M. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED WIRE MESH GLASS PANELS AT STAIRWELLS DIVIDERS WERE BROKEN AND MISSING. APPROX. 40 PIECES THROUGHOUT MULTIPLE STAIRWELLS AT VARIOU
#35721375Y
Aug 29, 2025
POP/IN-VIO
$0
Aug 5, 2025Construction CLASS - 1
REISSUE #35684940H. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: ILLUMINATION FOR EXITS; EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1; 27-381. NOTED EMERGENCY LIGHTS WITH BATTERY BACK UP POWER W
#35721599N
Aug 29, 2025
POP/IN-VIO
$0
Oct 3, 2024Construction CLASS - 2
REISSUE#35676359Y DATE OF ISSUE:07.12.2023 EMERGENCY SIGNS AT ELEVATORCALL STATION MISSING DEFECTIVE OR NON COMPLIANT WITH SECTION REQUIREMENTS AT THE TIME OF INSPECTION OBSERVED & NOTED FIRST FLOOR ELEVATOR &
#35692230N
Dec 6, 2024
POP/IN-VIO
$0
Oct 3, 2024Construction CLASS - 2
REISSUE#35676357K DATE OF ISSUE:07.12.2023 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.AT THE TIME OF INSPECTION NOTED & OBSERVED THAT AT SEVERAL STAIRWELLS THROUGHOUT(DIFFERENT FLOORS)THE BUILDING,DI
#35692227M
Dec 6, 2024
POP/IN-VIO
$0
Oct 3, 2024Construction CLASS - 2
REISSUE#35676355R DATE OF ISSUE:07.12.2023 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.AT THE TIME OF INSPECTION NOTED & OBSERVED THAT AT CELLAR LEVEL POOL PUMP ROOM,CONCRETE AROUND POOL IN STATE OF D
#35692229X
Dec 6, 2024
POP/IN-VIO
$0
Oct 3, 2024Construction CLASS - 2
REISSUE#35676356Z DATE OF ISSUE:07.12.2023 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.AT THE TIME OF INSPECTION NOTED & OBSERVED AT BASEMENT LEVEL SWIMMING POOLS(BAYS & UNIT)BOOTH REAR DOUBLE DOORS A
#35692228Y
Dec 6, 2024
POP/IN-VIO
$0
Oct 3, 2024Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER,ILLUMINATION FOREXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27-381.AT THETIME OF INSPECTION OBSERVED & NOTED THAT AT 3RD FLOOR LIBRARY INSIDE 3
#35684940H
Dec 6, 2024
POP/IN-VIO
$0
Jul 12, 2023Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED AT SEVERAL STAIRWELLS THROUGHOUT THE BUILDING, DIVIDERS WITH MISSING OR BROKEN WIRE MESH GLASS PANELS. APPROX 40PCS AT STAIRWELL "A" 3RD, 4TH, 5TH FL
#35676357K
Nov 3, 2023
POP/IN-VIO
$0
Jul 12, 2023Construction CLASS - 1
REISSUE#3565473Z FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED AT CELLAR LEVEL POOL PUMP ROOM, CONCRETE AROUND POOL IN STATE OF DISREPAIR, ADVANCED DECAY, RUSTING STEEL BEAMS IN CEILING. NOTED AR
#35676355R
Nov 3, 2023
POP/IN-VIO
$0
Jul 12, 2023Construction CLASS - 2
EMERGENCY SIGNS AT ELEVATOR CALL STATIONS MISSING, DEFECTIVE OR NON COMPLIANT WITH SECTION REQUIREMENTS. NOTED AT THE FIRST FLOOR ELEVATOR"A" LANDING, MISSING EMERGENCY SIGN WHICH IS REQUIRED TO DISPLAY A DIAGR
#35676359Y
Nov 3, 2023
POP/IN-VIO
$0
Jul 12, 2023Construction CLASS - 2
REISSUE#35654764K. FAILURE TO MAINTAIN BUILDING CODE COMPLIANT MANNER. NOTED AT BASEMENT SWIMMING POOLS (BAYS & UTILS) BOTH REAR DOUBLE DOORS ARE RACKED & DIFFICULT TO OPEN. ADDITIONALLY AT 5TH FL STAIR "A", 4T
#35676356Z
Nov 3, 2023
POP/IN-VIO
$0
Oct 13, 2022Elevators CLASS - 1
RESTORE TO SERVICE. FILE FOR DISMAMTLE.
#39071966J
Oct 31, 2022
POP/IN-VIO
$0
Jun 17, 2022Elevators CLASS - 1
RESTORE TO SERVICE
#39064397N
Jul 8, 2022
PENDING
$3,125
May 19, 2022Construction CLASS - 1
FAILURE TO MAINTAIN BLDG IN CODECOMPLIANT MANNER CONCRETE AROUND POOL IN CELLAR IN ADVANCED DECAY,RUSTING STEEL BEAM IN CEILING W/PARTS OF STEEL&CONCRETE FALLING,TEMP SHORING PUT AROUND BOTH PARTS,PIPE IN AREA
#35654763Z
Sep 16, 2022
POP/IN-VIO
$0
May 19, 2022Construction CLASS - 2
REISSUE35577370L FAILURE TO MAINTAIN BLDG IN CODECOMPLIANT MANNER SWIMMING POOL AREA BSMT LEVEL REAR DOUBLE DOORS B/W BOYS&GIRLS POOL RACKET&DIFFICULT TO OPEN&CLOSE.REPAIR &OR REPLACE
#35654764K
Sep 16, 2022
POP/IN-VIO
$0
Jan 10, 2022Elevators CLASS - 1
97X17: 97-X-17 CLASS 1 RESTORE TO SERVICE. REPAIR ELEVATOR DEVICE & RESTORE TO SERVICE IMMEDIATELY CALL N.Y.C DEPT OF BUILDINGS ELEVATOR DIVISION FOR REINSPECTION
#38274331J
Apr 29, 2022
POP/IN-VIO
$0
Jun 1, 2021Construction CLASS - 2
REISSUE35473277K FAILURE TO MAINTAIN BLDG IN CODECOMPLIANT MANNER.@CELLAR LEVEL,BELOW SWIMMING POOL IN POOL FILTER/PUMP AREA CEILING HAS SPALLING MASONRY&SOME AREAS MISSING MASONRY W/EXPOSED STEEL&REBAR.REPAIR
#35577362L
Oct 1, 2021
POP/IN-VIO
$0
Jun 1, 2021Construction CLASS - 2
FAILURE TO MAINTAIN BLDG IN CODECOMPLIANT MANNER.@SWIMMING POOL@REAR IN BSMT.DOUBLE DOORS B/W 2SWIMMING RACKED&DIFFICULT TO OPEN&CLOSE.REPAIR &/OR REPLACE.
#35577370L
Oct 1, 2021
POP/IN-VIO
$0
May 28, 2020Construction CLASS - 2
REISSUE ECB#35423329H ISSUED 7-9-19 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. AT BASEMENT LEVEL UNDER(POOLS)SPALLING CONCRETE MISSING STEEL EXPOSED. ALSO SPALLING AT POOL LEVEL & CRACKS THROUGHOUT.
#35473277K
Sep 18, 2020
POP/IN-VIO
$0
Jul 9, 2019Construction CLASS - 2
RE-ISSUE #35334376X.FAILURE TO MAINTAIN BLD.IN CODE COMPLIANT MANNER.AT BASEMENT LEVEL UNDER(POOLS)SPALLING CONCRETE MISSING STEEL EXPOSED. ALSO,SPALLING AT POOL LEVEL,& CRACKS (THROUGHOUT).REM:COMPLY WITH CODE
#35423329H
Sep 20, 2019
POP/IN-VIO
$0
May 17, 2018Construction CLASS - 2
REISSUE #34508817N FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER NOTED: AT BASEMENT LEVEL UNDER POOL THERE ARE SECTIONS SPALDINGCONCRETE MISSING EXPOSING STEEL BEAMS AND REBAR. RMDY: REPAIR AND/OR R
#35334376X
Aug 31, 2018
POP/IN-VIO
$0
Jun 6, 2017Construction CLASS - 2
REISSUE#35213822X FAILURE TO MAINTAIN BLDG IN CODE COMPLAINT MANNER. NOTED: AT CELLAR POOL AREA SERVICE,EXPOSED REBARS SPALLING CEILING TEMPORARY 2X2 WOOD SHORING IN PLACE EXPOSED STREET GIRDERS. REMEDY: COMPLY
#35267600Y
Sep 1, 2017
POP/IN-VIO
$0
Oct 18, 2016Construction CLASS - 2
REISSUE #35101703R ISSUED: 6-27-14 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER(INTERIOR). NOTED: AT CELLAR POOL AREA SERVICE(AREA): EXPOSED REBARS SPALLING CEILING TEMPORARY 2X2 WOOD(SHORING)IN PLACE FOR
#35213822X
Jan 6, 2017
POP/IN-VIO
$0
Jun 27, 2014Construction CLASS - 2
RE-ISSUE # 35018361Z. SPALLING CONCRETE CEILING. AT POOL SERVICE AREA, THE CEILING IS SEVERELY SPALLING WITH EXPOSED REBARS & TEMP WOOD SHORING IN PLACE FOR EXPOSED STREET GIRDERS, AREA AFFECTS BOTH POOL'S DEC
#35101703R
Aug 29, 2014
POP/IN-VIO
$0
Jun 3, 2013Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.REISSUE #34861606K.SPALLING CONCRETE @UNDERSIDE OF POOL,REBAR EXPOSED. REM:REPAIR CONCRETE.
#35018361Z
Aug 16, 2013
POP/IN-VIO
$0
Jun 10, 2010Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLAINT MANNER NOTED: REISSUE34508817N,34586864J,34770670L,34646858P,BASEMENT LEVEL UNDER POOL SPALDING CONCRETE MISSING SECTIONS OF CONCRETE EXPOSING REBAR LATHE CONCRE
#34861606K
Sep 17, 2010
WRITTEN OFF
$0
Feb 19, 2009Construction CLASS - 2
REISSUE 34646858P AT SUBLEVEL POOL AREA,BELOW POOL CONCRETE REBAR'S ARE EXPOSED THRU-OUT & CONCRETE IS SPALLING. REMEDY: REPAIR WALL.
#34770670L
Jul 10, 2009
WRITTEN OFF
$0
May 7, 2008Construction Hazardous
REISSUE 345868645J INTERIOR CONCRETE IS SPAULING & REBARS ARE EXPOSED LOCATED BELOW POOL PERIMETER REMEDY:REPAIR CONCRETE
#34646858P
Jun 27, 2008
WRITTEN OFF
$0
Jul 5, 2007Construction Hazardous
REISSUE#34508817N.INTERIOR CONCRETE AROUND POOL EXPOSING REBAR. REMEDY:REPAIR/REPLACE CONCRETE
#34586864J
Sep 21, 2007
WRITTEN OFF
$0
Mar 29, 2006Construction Hazardous
REISSUE: 34466398P. INTERIOR CONCRETE IS SPALLING AND REBARS ARE EXPOSED LOCATED IN THE BASEMENT AROUND THE PERIMETER OF THE POOL. REMEDY: REPAIR CONCRETE
#34508817N
Jun 2, 2006
WRITTEN OFF
$0
DOB (5)
IssuedViolationStatus
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#06383
DOB VIOLATION - ACTIVE
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#06384
DOB VIOLATION - ACTIVE
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#06385
DOB VIOLATION - ACTIVE
Jul 22, 2010ELEVATOR

#9027/346372
DOB VIOLATION - ACTIVE
Jan 13, 1997LOCAL LAW 10/81 - ELEVATOR

#02135
DOB VIOLATION - ACTIVE
DOB NOW Safety (20)
IssuedViolationStatus
Oct 29, 2026Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction
Active
Oct 29, 2026Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction
Active
Oct 29, 2026Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction
Active
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction
Active
Oct 25, 2024Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device
Active
Oct 11, 2024Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction
Active
Oct 11, 2024Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction
Active
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Oct 29, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of CorrectionOpen
Oct 29, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of CorrectionOpen
Oct 29, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of CorrectionOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 5, 2026, 7:50 PM ET. BBL 2030590001.