3 floors · 2 apartments · 4,400 sq ft · built 1930 · class S2 · owner of record: 515 & 517 Coney Island, Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 43 days | Keep the report on file (not filed with DOB) |
| Annual property registration Check HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 287 days | Required only if the owner doesn't live there |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 14 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 408 days | Next cycle year 2027 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Nov 9, 2010 | Construction CLASS - 1 WORK W.O A PERMIT. WORK NOTED 1- CELLAR INSTALLED 6 CIRCULAR COLUMNS 2- INSTALL METAL I BEAM APPROX 55 LF. 1ST FL INSTALLED NEW STORE FRONT(APPROX 20'X 10') GLASS WITH ALUM (METAL) FRAMING ROLL DOWN GATE 1ST F #34886756R | Apr 11, 2011 IN VIOLATION | $0 |
| Nov 9, 2010 | Construction CLASS - 1 WORK W.O A PERMIT. WORK NOTED CELLAR. 1- INSTALLED (2) HOT WATER 2- INSTALLED (2) HEATING UNITS. REMEDY: OBTAIN PERMIT OR RESTORE TO PRIOR LEGAL CONDITION #34886757Z | Apr 11, 2011 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jan 21, 2021 | CONSTRUCTION STRUCTURE RENDERED NON-COMPLIANT. AT TIME OF INSPECTION, DAMAGE OBSERVED TO HAVE BEEN SUSTAINED TO 3RD FLOOR LEVEL DUE TO FIRE AT 517 CONEY ISLAND AVE BROOKLYN. VACATE ENTIRE 3RD FLOOR LEVEL APARTMENT. #21-00064 | DOB VIOLATION - ACTIVE |
| Jun 22, 2018 | CONSTRUCTION #CN1402RA | DOB VIOLATION - ACTIVE |
| Feb 9, 2011 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00369 | DOB VIOLATION - ACTIVE |
| Feb 9, 2011 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00370 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Feb 9, 2011 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 9, 2011 | AEUHAZ FTC-AEU-HAZ | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)