5 floors · 20 apartments · 17,780 sq ft · built 1908 · class C6 · owner of record: 512 W 156 St Hdf Corp
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 46 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 46 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 62 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 290 days | Registered through 2027-09-01 |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 411 days | Next cycle year 2027 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-05 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Nov 14, 2024 | Construction CLASS - 2 OBSERVED AT EXPOSURE #2 STUCCO PEELING OF BRICKS IN VARIOUS LOCATIONS., REPAIR AND/OR REPLACE; REPAIR WALLS #39130164P | Jan 23, 2025 DEFAULT | $1,562 |
| Oct 17, 2019 | Construction CLASS - 2 FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#39007844P ISSUED ON 08-16-19 & TO FILE A C OF C PURSUANT TO 28-201.1 & 1RCNY 102-01. REMEDY: COMPLY W/COMM'S ORDER &/OR FILE A C OF C. #35430942L | Dec 26, 2019 IN VIOLATION | $1,250 |
| Aug 16, 2019 | Construction CLASS - 2 AT TIME OF INSPECTION OBSERVED FULL DEMO TAKING PLACE IN APARTMENT #51, DEMO AT APPROXIMATELY 75% AT TIME OF INSPECTION. NO PERMITS. WORK WITHOUT A PERMIT., OBTAIN ALL PERMITS #39007845R | Dec 12, 2019 DEFAULT | $3,125 |
| Aug 16, 2019 | Construction CLASS - 1 AT TIME OF INSPECTION OBSERVED FIRE STOPPING HAD BEEN REMOVED BETWEEN APARTMENT # 51 AND APARTMENT #54 DUE TO FULL DEMO TAKING PLACE IN APARTMENT #51 WITHOUT NECESSARY DOCUMENTATION. THERE IS CURRENTLY NO FIRE #39007844P | Dec 12, 2019 DEFAULT | $6,250 |
| Feb 21, 2018 | Boilers CLASS - 2 B254:50A,B,C,D,E:AS PER CLASS 2(B254)28-301.1 FAILURE TO MAINTAIN.ANTISIPHON VALVE NOT INSTALLED ON OIL PIPING;HOT WATER COIL PIPING NOT CAPPED.BACK FLOW PREVENTER DRAIN NOT PIPED DOWN;STEAM/WATER PIPING NOT IN #32092913Y | Apr 12, 2018 WRITTEN OFF | $0 |
| Dec 26, 2017 | Boilers CLASS - 2 50A,50B,50C,50D,50E,50F-AS PER CLASS 2 (B254)28.301.1 FAILURE TO MAINTAIN. 50A)RELIEF VALVES NEEDED ON COLD WATER PIPING FOR DOMESTIC HOT WATER COIL. 50B)LIMIT CONTROLS PIPING SIZED INCORRECTLY AND NO CLEANOUTS #32092704H | Jun 14, 2018 WRITTEN OFF | $0 |
| Sep 14, 2017 | Boilers CLASS - 2 40, 50-50) NEED TO FIX LIGHTS IN BOILER ROOM. #32091754L | Nov 2, 2017 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Feb 24, 2017 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT #00750 | DOB VIOLATION - ACTIVE |
| Mar 3, 2015 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT #04052 | DOB VIOLATION - ACTIVE |
| May 15, 2014 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT #05183 | DOB VIOLATION - ACTIVE |
| Dec 13, 2011 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT #04024 | DOB VIOLATION - ACTIVE |
| Jan 3, 2008 | LOCAL LAW 62/91 - BOILERS #01148 | DOB VIOLATION - ACTIVE |
| Feb 27, 2001 | LOCAL LAW 62/91 - BOILERS #08161 | DOB VIOLATION - ACTIVE |
| Feb 7, 2000 | LOCAL LAW 62/91 - BOILERS #08359 | DOB VIOLATION - ACTIVE |
| Mar 16, 1999 | LOCAL LAW 62/91 - BOILERS #08259 | DOB VIOLATION - ACTIVE |
| Feb 10, 1997 | LOCAL LAW 62/91 - BOILERS #10790 | DOB VIOLATION - ACTIVE |
| Sep 1, 1994 | LOCAL LAW 62/91 - BOILERS #01918 | DOB VIOLATION - ACTIVE |
| Aug 16, 1989 | CONSTRUCTION #STM01 | DOB VIOLATION - ACTIVE |
| Aug 16, 1989 | CONSTRUCTION #STM02 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Dec 15, 2025 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device | Active |
| Oct 25, 2024 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device | Active |
| Feb 24, 2017 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT | Active |
| Mar 3, 2015 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT | Active |
| May 15, 2014 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT | Active |
| Dec 13, 2011 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT | Active |
| Jan 3, 2008 | Boiler LL6291 | Active |
| Feb 27, 2001 | Boiler LL6291 | Active |
| Feb 7, 2000 | Boiler LL6291 | Active |
| Mar 16, 1999 | Boiler LL6291 | Active |
| Feb 10, 1997 | Boiler LL6291 | Active |
| Sep 1, 1994 | Boiler LL6291 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Apr 2, 2026 | B | Apt 1 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE MARBLE SADDLE AT ENTRANCE IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | May 7, 2026 |
| Apr 2, 2026 | B | Apt 1 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT FLOOR IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | May 7, 2026 |
| Apr 11, 2025 | B | Apt 31 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT CEILING AND EAST WALL IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 31, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 17546963 ISSUED 11-DEC-24 HAS BEEN UPGRADED TO CLASS B | May 16, 2025 |
| Dec 12, 2024 | C | Apt 31 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 31, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH | Jan 7, 2025 |
| Dec 12, 2024 | B | Apt 31 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 31, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH | Jan 16, 2025 |
| Dec 12, 2024 | B | Apt 31 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 31, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH | Jan 16, 2025 |
| Oct 28, 2024 | B | Apt 52 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 52, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH | Dec 2, 2024 |
| Oct 28, 2024 | C | Apt 52 · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 52, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH | Nov 11, 2024 |
| Oct 28, 2024 | C | Apt 52 · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER EXCEEDING THE MAXIMUM ALLOWABLE TEMPERATURE OF 130F DEGREES AT ALL PLUMBING FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 52, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH | Nov 3, 2024 |
| Oct 28, 2024 | B | Apt 52 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 52, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH | Dec 2, 2024 |
| Oct 24, 2024 | B | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE BOXES AND GARBAGE BAGS AT EAST COURT | Nov 28, 2024 |
| Oct 23, 2024 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH SET AT BUILDING ENTRANCE DOOR | Nov 6, 2024 |
| Oct 23, 2024 | C | Apt 2 · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Nov 6, 2024 |
| Sep 27, 2024 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM BOILER ROOM DOOR LOCKED AT CELLAR | Oct 3, 2024 |
| Sep 27, 2024 | B | Apt 2 · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Nov 1, 2024 |
| Sep 23, 2024 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES FLOWER POTS AT BUILDING FRONT STACK AT FIRE ESCAPE, 3rd STORY | Oct 28, 2024 |
| Sep 18, 2024 | C | Apt 2 · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR FRAME IN THE ENTRANCE LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 2, 2024 |
| Sep 18, 2024 | C | Apt 2 · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Sep 18, 2024 |
| Sep 12, 2024 | C | Apt 2 · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Sep 26, 2024 |
| Sep 12, 2024 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED BASEMENT DOOR | Sep 18, 2024 |
| Sep 12, 2024 | B | § 27-2005 HMC: REFIT DOOR AT BUILDING ENTRANCE | Oct 17, 2024 |
| Sep 12, 2024 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES PLANTS AND FLOWER POTS AT 3RD STORY BALCONY AT FRONT | Oct 17, 2024 |
| Sep 12, 2024 | C | Apt 2 · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Sep 10, 2024 |
| Apr 5, 2024 | B | Apt 31 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATE 6 SQ FT AT CEILING(APPROX. 2 SQ FT), EAST WALL (APPROX 2 SQ FT) AND SOUTH WALL (APPROX 2 SQ) IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 31, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH ORIGINAL VIO | May 10, 2024 |
| Dec 7, 2023 | B | Apt 31 · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ESCUTCHEON PLATE AT RISER IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 31, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH | Jan 11, 2024 |
| Dec 7, 2023 | B | Apt 31 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 31, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH | Jan 11, 2024 |
| Dec 4, 2023 | B | Apt 31 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND SOUTH WALL IN THE BATHROOM LOCATED AT APT 31, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH | Jan 8, 2024 |
| Dec 4, 2023 | B | Apt 31 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE BATHROOM LOCATED AT APT 31, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH | Jan 8, 2024 |
| Dec 4, 2023 | B | Apt 31 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE KITCHEN LOCATED AT APT 31, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH | Jan 8, 2024 |
| Dec 4, 2023 | B | Apt 31 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 31, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH | Jan 8, 2024 |
| Dec 4, 2023 | B | Apt 31 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 31, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH | Jan 8, 2024 |
| May 11, 2023 | A | § 27-2048 ADM CODE PAINT OR POST A SIGN INDICATING FLOORS AT ALL STORIES THROUGHOUT AT PUBLIC HALL | Aug 14, 2023 |
| May 11, 2023 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM | May 17, 2023 |
| Feb 27, 2023 | C | Apt 1 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Mar 25, 2023 |
| Jan 6, 2023 | B | Apt 1 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 10, 2023 |
| Jan 6, 2023 | B | Apt 1 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE SOUTH WALL, CEILING, SOUTH WALL, CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 10, 2023 |
| Jan 6, 2023 | B | Apt 1 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE SOUTH WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 10, 2023 |
| Jan 6, 2023 | B | Apt 1 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 10, 2023 |
| Jan 6, 2023 | B | Apt 1 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE NORTH WALL, NORTH WALL IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 10, 2023 |
| Jan 6, 2023 | B | Apt 1 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 10, 2023 |
| Jan 5, 2023 | C | Apt 1 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Jan 31, 2023 |
| Jan 5, 2023 | C | Apt 1 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Jan 31, 2023 |
| Jan 5, 2023 | B | Apt 1 · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE UPPER GLASS PANE AND LOWER GLASS PANE AT THE EAST WINDOW IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 9, 2023 |
| Jan 5, 2023 | B | Apt 1 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT THE EAST WINDOW FRAME SILL IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 9, 2023 |
| Aug 4, 2022 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING BETWEEN 2ND AND 3RD STORY AT PUBLIC HALL STAIRS | Nov 7, 2022 |
| Aug 4, 2022 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING BETWEEN 2ND AND 3RD STORY AT PUBLIC HALL STAIRS | Sep 8, 2022 |
| Jul 28, 2022 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSEHOLD ITEMS AT 3RD STORY BALCONY FRONT STACK | Sep 1, 2022 |
| Jul 28, 2022 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF POTTED PLANTS AT 5TH STORY BALCONY FRONT STACK | Sep 1, 2022 |
| Jul 28, 2022 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF HOUSEHOLD ITEMS AT 4TH STORY BALCONY FRONT STACK | Sep 1, 2022 |
| Apr 8, 2022 | B | Apt 31 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT NORTH WALL APRAPROX 2 SQ.FT IN THE KITCHEN LOCATED AT APT 31, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 14712518 ISSUED 08-DEC-21 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017 | May 13, 2022 |
| Dec 9, 2021 | B | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MAIL BOX DOOR AND LOCK TO APARTMENT # 54 , 1st STORY | Jan 13, 2022 |
| Dec 9, 2021 | B | Apt 31 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND EAST WALL IN THE KITCHEN LOCATED AT APT 31, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH | Jan 13, 2022 |
| Dec 9, 2021 | B | Apt 31 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND SOUTH WALL IN THE BATHROOM LOCATED AT APT 31, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH | Jan 13, 2022 |
| Oct 25, 2021 | C | Apt 54 · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE LEAKY AIR VALVE AT STEAN RISER IN THE 4th ROOM FROM NORTH LOCATED AT APT 54, 5th STORY, 1st APARTMENT FROM WEST AT NORTH | Oct 31, 2021 |
| Oct 25, 2021 | A | Apt 54 · § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION STEAM RISER AT NORTH WALL IN THE 4th ROOM FROM NORTH LOCATED AT APT 54, 5th STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 28, 2022 |
| Sep 17, 2019 | B | Apt 22 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 22, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 22, 2019 |
| Sep 17, 2019 | B | Apt 22 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE BATHROOM LOCATED AT APT 22, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 22, 2019 |
| Sep 17, 2019 | B | Apt 22 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL AND CEILING. IN THE KITCHEN LOCATED AT APT 22, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 22, 2019 |
| Jun 6, 2019 | B | Apt 32 · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE FIRE PROOF SELF CLOSING DOOR IN THE ENTRANCE LOCATED AT APT 32, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Jul 11, 2019 |
| Jun 5, 2019 | B | Apt 32 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 32, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Jul 10, 2019 |
Showing 60 of 122. Full list on the agency site.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 15, 2026, 7:37 AM ET. BBL 1021140030.