Brooklyn · Block 455 · Lot 1 · 11215

512 Carroll Street

3 floors · 85,075 sq ft · built 1931 · class M1 · owner of record: Roman Catholic Church

18open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
64dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 64 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 64 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 85,075 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 185 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 185 days
Annual filing
Energy audit and retro-commissioning (2035) Likely applies
Local Law 87 · Calendar year 2035
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 455). Agency page

Dec 31, 2035
in 3351 days
Next due 2035
Annual boiler inspection (5 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-16 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (5)
IssuedViolationHearingBalance
Jun 25, 2024Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.AT TIME OF INSPECTION OBSERVED EMERGENCY LIGHTS NOT WORKING PROPERLY:1FL STAIRWAY B TOTAL#2,1FL GYM TOTAL#4,1FL EXIT DOOR#1 TOTAL#2.REM:REPAIR OR REPLACE LI
#35677297M
Sep 4, 2024
POP/IN-VIO
$0
Jun 1, 2015Construction CLASS - 2
VIOLATION #34856133N ISSUED ON 4/14/10 FOR WORK WITH OUT A PERMIT ILLEGAL WORK AT NORTH SECTION OF CAFETERIA FOUND TO BE SUBDIVIDED TO CREATE OFFICE SPACES.REMEDY:COMPLY WITH THE NOTICE OF VIOLATION.
#35128984M
Jul 20, 2015
STIPULATION/IN-VIO
$0
Apr 14, 2010Unknown CLASS - 2
WORK W/O A PERMIT!ILLEGAL WORK NOTED:NORTH SECTIONS OF CAFETERIA FOUNDTO BE SUBDIVIDED TO CREATE OFFICE SPACES!REM:OBTAIN THE REQUIRED PERMIT & APPROVED FROM THE NYC DOB!
#34856133N
Nov 29, 2010
IN VIOLATION
$0
Jul 7, 2006Construction Hazardous
3B,16,19A,24A,25A,30A,32A,41C,44C,50A,50B,50C,50D,50E,50F-50A BOILER IMPROPERLY MAINTAINED &/OR DISCONNECTED 50B-FLUE CONNECTED TO OPERATINGBOILER OPEN & UNSEALED AT BASE(HAZARDOUS CONDITION REPAIR IMMEDIATELY)
#32051747R
Jul 9, 2007
IN VIOLATION
$0
Jul 7, 2006Boilers Non-Hazardous
50A,50B,32A,50C 50A CONTROL/GAUGE(OPERATING) TO BE SEPARATED FROM 1/4"LINE 50B-ISOLATION VALVE ON CONDERSATE RETURN LEAKING AT PACKING 50C-L.W.C.O. LEAKING/CORRODED
#32051746P
Jan 28, 2008
DEFAULT
$0
DOB (6)
IssuedViolationStatus
Nov 30, 2020ELEVATOR

#9027/694806
DOB VIOLATION - ACTIVE
Nov 18, 2019ELEVATOR

#9027/665157
DOB VIOLATION - ACTIVE
May 3, 2005ELEVATOR

#9444/128601
VIOLATION WORK WITHOUT PERMIT - ACTIVE
May 3, 1999CONSTRUCTION
HAZARDOUS
#306GN03
DOB VIOLATION - ACTIVE
May 3, 1999CONSTRUCTION

#306GN03
DOB VIOLATION - ACTIVE
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#27023
DOB VIOLATION - ACTIVE
DOB NOW Safety (7)
IssuedViolationStatus
Dec 15, 2025Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device
Active
Oct 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle C (premises is in Community District 6)
Active
Oct 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle C (premises is in Community District 6)
Active
Sep 11, 2024Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Report
Active
Sep 11, 2024Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2020 Cat1 Test Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Report
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 28, 2026, 11:05 PM ET. BBL 3004550001.