4 floors · 82,992 sq ft · built 1931 · class W1 · owner of record: Nyc Department Of Education
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 67 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 82,992 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 188 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 188 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 18 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1163 days | Next cycle year 2029 |
| Energy audit and retro-commissioning (2029) Likely applies Local Law 87 · Calendar year 2029 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 7849). Agency page | Dec 31, 2029 in 1163 days | Next due 2029 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-01-13 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Mar 2, 2026 | Construction CLASS - 2 RE-ISSUED 35691718M. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3; 27-345. MULTIPLE 6" PIPE PENETRATION WAS OBSERVED IN GAS METER ROOM, HENCE THE ROOM IS NOT FIRE STOPPED #35722286R | Apr 2, 2026 POP/IN-VIO | $0 |
| Mar 2, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1; 27-371(J). AT THE TIME OF INSPECTION, THE FOLLOWING ROOM DOORS HAD TURN KNOB HANDLES:-417, 418, 416, #35722287Z | Apr 2, 2026 POP/IN-VIO | $0 |
| Mar 2, 2026 | Construction CLASS - 2 RE-ISSUED 35691719Y. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PERBC 1006.1; 27-381. AT THE TIME OF INSPECTION, EMERGENCY LIGHTS #26, #2 #35722285P | Apr 2, 2026 POP/IN-VIO | $0 |
| Mar 2, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. BROKEN CLERESTORY WINDOW IN ROOM 414. BROKEN TRIM MOLDING WITH LOOSE PIECES OF WALL BOARD AT ROOM DOOR 212. CORRODED BASE FRAME AT ERT #7 DOORS. EXIT #10 V #35722288K | Apr 2, 2026 POP/IN-VIO | $0 |
| Mar 2, 2026 | Construction CLASS - 2 RE-ISSUED 35691717K. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT THE TIME OF INSPECTION, THE FOLLOWING ROOM DOORS WERE NOT SELF-CLOSING PROPERLY:-417, 418, 416, 412, 301, 302, 304, 303, 308, 306, #35722283L | Apr 2, 2026 POP/IN-VIO | $0 |
| Mar 17, 2025 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1; 27-381. NOTED: ON THE FOURTH FLOOR HALLWAY NEXT TO ROOM 459 AND 418, THIRD FLOO #35691719Y | Apr 16, 2025 POP/IN-VIO | $0 |
| Mar 17, 2025 | Construction CLASS - 2 RE-ISSUE #35663524X. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: OBSERVED ON THE FORTH FLOOR, THE LEFT DOOR TO THE GYMNASIUM, ON THE THIRD FLOOR, ON THE SECOND FLOOR ROOM 210, THESE DOORS ARE #35691717K | Apr 16, 2025 POP/IN-VIO | $0 |
| Mar 17, 2025 | Construction CLASS - 2 RE-ISSUE #35663523Y. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3; 27-345. NOTED: OBSERVED IN THE CELLAR THE GAS METER ROOM CEILING THERE ARRE SEVERAL HOLES AROUND THE PI #35691718M | Apr 16, 2025 POP/IN-VIO | $0 |
| Apr 12, 2024 | Construction CLASS - 2 REISSUE#35671970X FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER:NO FIRE STOPPING PER BC 712.3;27-345.NOTED:OBSERVED IN THE BASEMENT IN THE GAS METER ROOM,THERE ARE SEVERAL HOLES IN THE CEILING AROUND TH #35663523Y | Jul 24, 2024 POP/IN-VIO | $0 |
| Apr 12, 2024 | Construction CLASS - 2 REISSUE#35671969Z FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:OBSERVED ON THE FOURTH FLOOR THE ENTRANCE DOOR TO THE GYMNASIMUM THE LEFT SIDE IS NOT CLOSING PROPERLY.ALSO ON THE THIRD FLOOR ROOM #35663524X | Jul 24, 2024 POP/IN-VIO | $0 |
| Mar 8, 2023 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:OBSERVED DURING INSPECTION OF FIRE PROOF SELF CLOSING DOOR AT STAIR E BY RM 302, STAIR G ROOM 309 & BY RM 210 WERE NOT OPERATIONAL WHEN TEST DUE TO RA #35671969Z | Jun 21, 2023 POP/IN-VIO | $0 |
| Mar 8, 2023 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NO FIRE STOPPING PER BC 712.3, 27-345.NOTED:OBSERVED DURING INSPECTION OF BASEMENT GAS METER ROOM OLD PIPE HOLE IN CEILING NOT PROPERLY SEALED WITH FIRE STO #35671970X | Jun 21, 2023 POP/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #18732 | DOB VIOLATION - ACTIVE |
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #18733 | DOB VIOLATION - ACTIVE |
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #18734 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 18, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle B (premises is in Community District 18) | Active |
| Oct 25, 2024 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device | Active |
None open.