5 floors · 16 apartments · 9,490 sq ft · built 1877 · class C7 · owner of record: Owemanco In The Village L.P.
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 47 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 63 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 291 days | Registered through 2027-09-01 |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1143 days | Next cycle year 2029 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-02 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jun 29, 2026 | Signs CLASS - 1 PROHIBITED OUTDOOR ADVERTISING COMPANY SIGN ON SIDEWALK SHED OR CONSTRUCTION FENCE. AT TIME OF INSPECTION OBSERVED MULTIPLE ILLEGALLY POSTED ADVERTISING SIGNS POSTED ON CONSTRUCTION FENCE., REMOVE ILLEGAL SIGN #39194193R | Mar 5, 2027 | $10,000 |
| Issued | Violation | Status |
|---|---|---|
| Nov 20, 2012 | LANDMARK #13-0359 | DOB VIOLATION - ACTIVE |
| May 4, 1994 | ELECTRIC SIGNS #02AM04 | DOB VIOLATION - ACTIVE |
| Jul 1, 1992 | LANDMARK #93-0001 | DOB VIOLATION - ACTIVE |
| Jan 5, 1989 | CONSTRUCTION #A3MS02 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Dec 15, 2025 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Sep 8, 2026 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES AT VESTIBULE , 1st STORY | Oct 13, 2026 |
| Aug 25, 2026 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT BULKHEAD CEILING | Sep 29, 2026 |
| Aug 25, 2026 | B | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK ABOVE CEILING AT BULKHEAD | Sep 29, 2026 |
| Aug 25, 2026 | B | Apt 13 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 13, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Sep 29, 2026 |
| Aug 25, 2026 | B | Apt 13 · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 13, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Sep 29, 2026 |
| Aug 25, 2026 | C | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING TREAD AT FIRE ESCAPE AT 2ND STORY 11TH TREAD FROM BOTTOM AT BUILDING FRONT AT FIRE ESCAPE, 2nd STORY | Aug 31, 2026 |
| Aug 25, 2026 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 5th STORY | Sep 29, 2026 |
| Aug 25, 2026 | B | Apt 13 · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK ABOVE CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 13, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Sep 29, 2026 |
| Aug 25, 2026 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 5th STORY | Nov 28, 2026 |
| Dec 26, 2025 | B | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING AT 1st PUBLIC HALL BULKHEAD FROM NORTH, 5th STORY | Jan 30, 2026 |
| Dec 26, 2025 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT 1st PUBLIC HALL BULKHEAD FROM NORTH, 5th STORY | Jan 30, 2026 |
| Dec 26, 2025 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH SET AT FIRE DOOR LEADING TO NORTH YARD AT PUBLIC HALL, 1st STORY | Jan 9, 2026 |
| Dec 26, 2025 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT 1st PUBLIC HALL BULKHEAD FROM NORTH, 5th STORY | Mar 31, 2026 |
| Dec 26, 2025 | B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AT FIRE DOOR LEADING TO NORTH YARD AT PUBLIC HALL, 1st STORY | Jan 30, 2026 |
| Sep 23, 2025 | B | Apt 8 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10SQ.FT AT CEILING IN THE BATHROOM LOCATED AT APT 8, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Oct 28, 2025 |
| Apr 1, 2024 | B | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATELY 5 SQ FT AT THE CEILING AT PUBLIC HALL STAIRS, 2nd STORY ORIGINAL VIOLATION 16485315 ISSUED 30-NOV-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b). | May 6, 2024 |
| Date | Source | What | Now |
|---|---|---|---|
| Sep 8, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES AT VESTIBULE , 1st STORY | Open |
| Sep 8, 2026 | HPD C | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHENETTE LOCATED AT APT 11, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Closed |
| Aug 25, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT BULKHEAD CEILING | Open |
| Aug 25, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK ABOVE CEILING AT BULKHEAD | Open |
| Aug 25, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 13, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Open |
| Aug 25, 2026 | HPD B | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 13, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Open |
| Aug 25, 2026 | HPD C | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING TREAD AT FIRE ESCAPE AT 2ND STORY 11TH TREAD FROM BOTTOM AT BUILDING FRONT AT FIRE ESCAPE, 2nd STORY | Open |
| Aug 25, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 5th STORY | Open |
| Aug 25, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK ABOVE CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 13, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Open |
| Aug 25, 2026 | HPD A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 5th STORY | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)