3 floors · 31,500 sq ft · built 1931 · class M1 · owner of record: The Universal Church, Inc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 66 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 31,500 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 187 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 187 days | Annual filing |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-22 (Accepted). Agency page | On file | 2026 reports accepted |
None open.
| Issued | Violation | Status |
|---|---|---|
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION #05814 | DOB VIOLATION - ACTIVE |
| Jan 17, 2014 | CONSTRUCTION BOROUGH COMMISSIONER HAS ISSUED A 15 DAY LETTER OF INTENT TO REVOKE APP#320325457 ON 1/13/14 DUE TO (1) OBJECTIONS MUST BE WRITTEN SIGN SE ALED ALT1 7 PAA MUST BE FILED (2) ZONING DISTRICT (3) PROVIDE ROOF ACC ESS, STOP ALL WORK, MAKE SAFE ONLY #0602SP | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 2, 2023 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction | Active |
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jun 18, 2008 | B | SECTION 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE ALUMINUM DOOR SADDLE NORTH STREET ENTRANCE TO BLDG | Jul 23, 2008 |
| Jun 18, 2008 | B | SECTION 27-2005 ADMIN. CODE: MAKE SAFE BY PROPERLY REPAIRING THE STRUCTURAL DEFECT. STAIR BADLY SAGGED 1ST STORY PUBLIC HALL TO INTERMEDIATE LANDING | Jul 23, 2008 |
| Jun 18, 2008 | B | SECTION 27-2005, 2007 ADMIN. CODE: REMOVE ALL ENCUMBRANCES CONSISTING OF 5 RADIATORS 1ST LANDING UP 3RD STORY TO ROOF STAIR | Jul 23, 2008 |
| Jun 18, 2008 | B | SECTION 27-2032, 2034 ADNIM. CODE: DISCONTINUE USE OF ILLEGAL SPACE AND/OR HOT WATER HEATER AND PROVIDE FILED FOR & APPROVED HEATER WHICH OBTAINS COMBUSTION AIR DIRECTLY FROM OUTSIDE THE BUILDING OR APPROVED CENTRAL SYSTEM BATHROOM 2ND STORY GAS FIRED HOT WATER HEATER | Jul 23, 2008 |
| Jun 18, 2008 | B | SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE PLASTER BOARD CEILING BATHROOM 2ND STORY APT | Jul 23, 2008 |
| Jun 18, 2008 | B | SECTION 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE WINDOW SASH 2ND ROOM FROM SOUTH 2ND STORY APT | Jul 23, 2008 |
| Jun 18, 2008 | A | SECTION 27-2013 ADMIN. CODE: PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILINGS PUBLIC HALLS ALL STORIES | Sep 21, 2008 |
| Jun 18, 2008 | C | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE WALL LIGHT FIXTURE 1ST TO 2ND STORY PUBLIC HALL STAIR EXPOSED WIRING | Jun 24, 2008 |
| Jun 18, 2008 | C | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE CERAMIC TILE CEMENT BASE AND METAL PAN-TOP LANDING 1ST TO 2ND STORY PUBLIC HALL STAIR | Jun 24, 2008 |
| Jun 18, 2008 | C | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE CERAMIC TILE CEMENT BASE AND METAL PAN-2ND LANDING UP 2ND TO 3RD STORY PUBLIC HALL STAIR | Jun 24, 2008 |
| Jun 18, 2008 | C | SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE CERAMIC TILE --CEMENT BASE AND METAL PAN--3RD STORY TO ROOF STAIR | Jun 24, 2008 |
| Jun 18, 2008 | C | SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING MARBLE NOSING 3RD STORY PUBLIC HALL LANDING | Jun 24, 2008 |