Queens · Block 2306 · Lot 10 · 11377

51-31 48 Street

2 floors · 2 apartments · 1,649 sq ft · built 1920 · class B1 · owner of record: Dape, Dape G

10open violations
$2,500ECB/OATH penalties owed
0HPD class C (immediately hazardous)
304dto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Check
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 304 days
Required only if the owner doesn't live there

Open violations

ECB / OATH (1) · $2,500 owed
IssuedViolationHearingBalance
Sep 16, 2025Construction CLASS - 1
AT TIME OF INSPECTION OBSERVED REAR CMU WALL IN STATE OF DISREPAIR WITH CRACKS AND BULGES AT MULTIPLE LOCATIONS AND IN DANGER OF POTENTIAL FURTHER COLLAPSE AT EXP.3 (REAR OF BUILDING)., REPAIR AND/REPLACE
#39160640Y
Feb 8, 2027
PENDING
$2,500
DOB (2)
IssuedViolationStatus
Sep 17, 2025CONSTRUCTION
FAILURE TO MAINTAIN.REAR CMU WALL OF GARAGE HAS CRCKS&OPEN JOINTS IN MULT LOCATIONS,STEP CRCKS OBSRVD@TOP OR REAR WALL@NORTH END NO INT ACCESS@TIME OF INSPCTN,BUT CMU WALLS OBSRVD TO BE IMMED BRACED.1.NYSPE STRCT ENG TO IMMED EVAL ENT GARAGE&DSGN RPAIRS,2.FILE FOR RPAIRS BY 11/17/25,3.OBTN PRMTS&STR
#FEU40208BS
DOB VIOLATION - ACTIVE
Sep 16, 2025CONSTRUCTION
AT TIME OF INSPECTION OBSERVED REAR WALL OF THE GARAGE IN STATE OF DISREPAIR, SHIFTED CMU BLOCKS, AND MISSING MORTAR. ENGINEERS REPORT REQUESTED
#25-02148
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (7) · C 0 · B 6 · A 1
IssuedClassViolationCorrect by
Jul 18, 2008BApt 2FL · SECTION 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE WASH BASIN IN THE BATHROOM LOCATED AT APT 2FL, 2nd STORY, APARTMENT AT SOUTHAug 22, 2008
Jul 18, 2008AApt 2FL · SECTION 27-2026 ADMIN. CODE: RESET, SO AS TO SECURE A PROPER AND TIGHT CONNECTION, THE WATER CLOSET BOWL ... IN THE BATHROOM LOCATED AT APT 2FL, 2nd STORY, APARTMENT AT SOUTHOct 21, 2008
Jul 18, 2008BApt 2FL · SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL/BUZZER IN THE ENTIRE APARTMENT LOCATED AT APT 2FL, 2nd STORY, APARTMENT AT SOUTHAug 22, 2008
Jul 18, 2008BApt 2FL · SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2FL, 2nd STORY, APARTMENT AT SOUTHAug 22, 2008
Jul 18, 2008BApt 2FL · SECTION 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2FL, 2nd STORY, APARTMENT AT SOUTHAug 22, 2008
Jul 18, 2008BApt 2FL · SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF VERMIN BED BUGS IN THE ENTIRE APARTMENT LOCATED AT APT 2FL, 2nd STORY, APARTMENT AT SOUTHAug 22, 2008
Jul 18, 2008BApt 2FL · SECTION 27-2026 ADMIN. CODE: REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATH TUB IN THE BATHROOM LOCATED AT APT 2FL, 2nd STORY, APARTMENT AT SOUTHAug 22, 2008

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)