4 floors · 128,000 sq ft · built 1974 · class I1 · owner of record: Beach 50th Street Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 50 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 128,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 171 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 171 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 14 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 415 days | Next cycle year 2027 |
| Energy audit and retro-commissioning (2032) Likely applies Local Law 87 · Calendar year 2032 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 15842). Agency page | Dec 31, 2032 in 2242 days | Next due 2032 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-04 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Mar 30, 2026 | Construction CLASS - 1 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER VIO #030326PI41403HZ CONTROL #348069 DATED 03/03/26. NO COMPLIANCE ON FILE FOR ANNUAL PARAPET OBSERVATION REPORT. REMEDY: COMPLY WITH THE COMMISSIONER'S ORDER. #35718822J | Jun 1, 2026 DEFAULT | $12,500 |
| Mar 3, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.OBSERVED HAZARDOUS CONDITIONS AT VARIOUS LOCATIONS WITH THE EXTERIOR FACADE OF THE BUILDINGS.UPTO 97-NINETY SEVEN AREAS,BUT NOT LIMITED TO AND CONSISTING OF #35718959K | Mar 25, 2027 DEFAULT | $2,530 |
| Issued | Violation | Status |
|---|---|---|
| Mar 3, 2026 | CONSTRUCTION CORRECTIVE ACTION PLAN REQ'D-OBSVD HAZ COND @ VARIOUS LOCATIONS W/THE FACADE OF THE BLDG.97 AREAS CONSISTING OF LOOSE,UNSTABLE,DISLODGED, DETACHING BRICKS W/CRACKS AND DETERIORATED MORTAR.THESE DEFICIENCIES ARE AT RISK OF FALLING AND/OR COLLAPSE. OWNER TO IMMED RETAIN REG DESIGN PROF TO EVAL ENITE B #PI41402HZ | DOB VIOLATION - ACTIVE |
| Mar 3, 2026 | CONSTRUCTION FTM BLDG IN A CODE COMPLIANT MANNER-HAZ FACADE CONDITIONS WERE FOUND ON EXP4,OBSVD SEVERAL AREAS W/LOOSE,UNSTABLE,DISLODGED,DETACHING BRICKS W/CRACKS & DETERIORATED MORTAR.THESE STRUCT DEFICIENCIES WERE DEEMED TO PRESENT AN IMMED HAZ TO PUBLIC SAFETY.VACATE ALL AREAS ALONG EXP1&ACCESS TO THE PARKING #PI41401HZ | DOB VIOLATION - ACTIVE |
| Mar 3, 2026 | CONSTRUCTION FTM BLDG IN CODE COMPLIANT MANNER-OBSVD UPTO 7 PARAPET WALL SECTIONS BUT NOT LIMITED TOO THAT ARE SLIGHTLY LEANING INWARD TOWARD ROOF DECK DUE TO DETERIORATED MORTAR JOINTS ON EXTERIOR EALL TO THE BLDG. AN ANNUAL PARAPET OBSERVATION REPORT IS REQ'D T/BE COMPL FOR 2025. SUBMIT ANNUAL PARAPET OBSERVAT #PI41403HZ | DOB VIOLATION - ACTIVE |
| Jan 31, 2005 | LOCAL LAW 62/91 - BOILERS #22495 | DOB VIOLATION - ACTIVE |
| Jan 31, 2005 | LOCAL LAW 62/91 - BOILERS #22494 | DOB VIOLATION - ACTIVE |
| May 4, 1998 | LOCAL LAW 62/91 - BOILERS #30251 | DOB VIOLATION - ACTIVE |
| May 4, 1998 | LOCAL LAW 62/91 - BOILERS #30250 | DOB VIOLATION - ACTIVE |
| Jan 13, 1997 | LOCAL LAW 10/81 - ELEVATOR #04146 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| Sep 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
| Sep 30, 2026 | DOB Safety | AEUHAZ: | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 11, 2026, 9:36 AM ET. BBL 4158420100.