1 floors · 2,433 sq ft · built 1984 · class K1 · owner of record: Beacon 1 Holdings Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 69 days | Keep the report on file (not filed with DOB) |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 434 days | Next cycle year 2027 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 12, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION, OBSERVED CLOSED PROPOSED 10-STORY NB SITE WITH FENCE EXTENDED ONTO THE SIDEWALK. BICYCLE RING AND FENCE REDUCED THE WALKWAY TO LESS THAN 3 FEET. NO WHEELCHAIR RAMP OR ALTERNATE-CROSSWALK #39559112P | Nov 19, 2026 PENDING | $2,400 |
| Sep 12, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION, OBSERVED CLOSED PROPOSED 10-STORY NB SITE WITH YODOCKS USED AS A PEDESTRIAN BARRIER. YODOCKS WERE NOT INTERLOCKED, NOT FILLED WITH WATER, AND NOT REMOVED WHILE THE SITE WAS UNATTENDED. CO #39559113R | Nov 19, 2026 PENDING | $1,250 |
| Sep 12, 2026 | Unknown CLASS - 2 AT TIME OF INSPECTION, OBSERVED CLOSED PROPOSED 10-STORY NB SITE IN FOUNDATION PHASE WITH 9,915 SF PROPOSED. NO WATCHPERSON WAS PRESENT. INSPECTOR KNOCKED, WAITED, AND CALLED OUT WITH NO RESPONSE. LACK OF WATCH #39559111N | Nov 19, 2026 PENDING | $2,500 |
| Aug 27, 2026 | Construction CLASS - 1 OBS. 1-SIDED FNDN WALL FORM/SHORING NONCONFORMING TO RDP DETAIL 16/FW-005. STEEL-PIPE/TIMBER BRACES ENDED LOOSE ON SLAB/WOOD; NEITHER REQ'D 4X4/#5 REBAR ANCHOR ASSEMBLIES W/SPEC'D SPACING/EMBEDMENT NOR APPROVED #39558478P | Nov 5, 2026 | $2,500 |
| Aug 27, 2026 | Site Safety CLASS - 1 OBS. ACTIVE 1-SIDED FNDN WALL FORMWORK ADJ. EXISTING BLDG. #66 STAY-FORM MFR. SPECS REQ'D BY RDP PLANS WERE NOT MAINTAINED ONSITE/PROVIDED UPON REQUEST; THUS PLAN-SPECIFIED CAPACITIES, BRACING/ANCHOR SPACING, F #39558479R | Nov 5, 2026 PENDING | $2,500 |
| Jul 23, 2026 | Construction CLASS - 2 OBSERVED CLOSED SITE OF A PROPOSED 10 STORY BUILDING IN EXCAVATION PHASE. CONSTRUCTION FENCE HAD DEFECTS. FENCE WAS OUT OF PLUMB ALSO OBSERVED PROTRUDING WOOD. THIS POSES UNSAFE CONDITIONS FOR PEDESTRIANS. VIO #39557009H | Nov 12, 2026 | $1,000 |
| Jul 23, 2026 | Construction CLASS - 1 OBSERVED INADEQUATE HOUSEKEEPING ON SITE WITH COMBUSTIBLE MATERIALS NOT STORED IN DESIGNATED CONTAINERS/ AREAS BC 3303.4 & 27-1018- FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS. REMEDY: M #39557010P | Nov 12, 2026 | $2,500 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Jan 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle D (premises is in Community District 12) | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Sep 12, 2026 | ECB | Construction: AT TIME OF INSPECTION, OBSERVED CLOSED PROPOSED 10-STORY NB SITE WITH FENCE EXTENDED ONTO THE SIDEWALK. BICYCLE RING AND FENCE REDUCED THE WALKWAY TO LESS THAN 3 FEET. NO WHEELCHAIR RAMP OR ALTERNATE-CROSSWALK | Open |
| Sep 12, 2026 | ECB | Construction: AT TIME OF INSPECTION, OBSERVED CLOSED PROPOSED 10-STORY NB SITE WITH YODOCKS USED AS A PEDESTRIAN BARRIER. YODOCKS WERE NOT INTERLOCKED, NOT FILLED WITH WATER, AND NOT REMOVED WHILE THE SITE WAS UNATTENDED. CO | Open |
| Sep 12, 2026 | ECB | Unknown: AT TIME OF INSPECTION, OBSERVED CLOSED PROPOSED 10-STORY NB SITE IN FOUNDATION PHASE WITH 9,915 SF PROPOSED. NO WATCHPERSON WAS PRESENT. INSPECTOR KNOCKED, WAITED, AND CALLED OUT WITH NO RESPONSE. LACK OF WATCH | Open |
| Aug 31, 2026 | DOB Safety | AEUHAZ: | Closed |
| Aug 27, 2026 | ECB | Construction: OBS. 1-SIDED FNDN WALL FORM/SHORING NONCONFORMING TO RDP DETAIL 16/FW-005. STEEL-PIPE/TIMBER BRACES ENDED LOOSE ON SLAB/WOOD; NEITHER REQ'D 4X4/#5 REBAR ANCHOR ASSEMBLIES W/SPEC'D SPACING/EMBEDMENT NOR APPROVED | Closed |
| Aug 27, 2026 | ECB | Site Safety: OBS. ACTIVE 1-SIDED FNDN WALL FORMWORK ADJ. EXISTING BLDG. #66 STAY-FORM MFR. SPECS REQ'D BY RDP PLANS WERE NOT MAINTAINED ONSITE/PROVIDED UPON REQUEST; THUS PLAN-SPECIFIED CAPACITIES, BRACING/ANCHOR SPACING, F | Open |
| Jul 23, 2026 | ECB | Construction: OBSERVED CLOSED SITE OF A PROPOSED 10 STORY BUILDING IN EXCAVATION PHASE. CONSTRUCTION FENCE HAD DEFECTS. FENCE WAS OUT OF PLUMB ALSO OBSERVED PROTRUDING WOOD. THIS POSES UNSAFE CONDITIONS FOR PEDESTRIANS. VIO | Closed |
| Jul 23, 2026 | ECB | Construction: OBSERVED INADEQUATE HOUSEKEEPING ON SITE WITH COMBUSTIBLE MATERIALS NOT STORED IN DESIGNATED CONTAINERS/ AREAS BC 3303.4 & 27-1018- FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS. REMEDY: M | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 23, 2026, 12:43 PM ET. BBL 1022430273.