5 floors · 201,756 sq ft · built 1923 · class W1 · owner of record: Nyc Department Of Education
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 201,756 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 168 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 168 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 412 days | Next cycle year 2027 |
| Energy audit and retro-commissioning (2029) Likely applies Local Law 87 · Calendar year 2029 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2229). Agency page | Dec 31, 2029 in 1143 days | Next due 2029 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-06-05 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Feb 18, 2026 | Construction CLASS - 2 EXIT DOOR NOT SELF-CLOSING PROPERLY AT THE TIME OF INSPECTION. AT 5TH.FL. GYM MAIN ENTRANCE 2 EXIT DOOR, 2ND. FL. NEAR STAIRWAY "G" 1 EXIT DOOR, AT 1ST FLOOR CAFETERIA MAIN ENTRANCE 2 EXIT DOORS, 1ST FLOOR CAFE #35725423H | Mar 10, 2026 POP/IN-VIO | $0 |
| Feb 18, 2026 | Construction CLASS - 2 REISSUE #35691806M DATE OF ISSUE: 02/24/2025. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NO FIRE STOPPING PER BC 712.3; 27-345. NO FIRE STOPPING THROUGH BASEMENT LEVEL HOLES THAT PENETRATE THROUGH W #35725422X | Mar 10, 2026 POP/IN-VIO | $0 |
| Feb 18, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1; 27-381. AT THE TIME OF INSPECTION OBSERVED AND NOTED AT 1ST. FL. CAFETERIA NEAR #35725424J | Mar 10, 2026 POP/IN-VIO | $0 |
| Feb 24, 2025 | Construction CLASS - 2 REISSUE: 35676169N-FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRESTOPPING THROUGHOUT BASEMENT. REMEDY: COMPLY WITH CODE. #35691806M | Apr 30, 2025 POP/IN-VIO | $0 |
| Feb 22, 2024 | Construction CLASS - 2 REISSUE#35663459Z-FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER:NO FIRESTOPPING PER BC 712.3;27-345.NOTED:OBSERVED AT VARIOUS LOCATIONS THROUGHOUT BSMT LEVEL,HOLES THAT PENETRATE THROUGH WALLS AND/OR CE #35676169N | Apr 22, 2024 POP/IN-VIO | $0 |
| Jun 13, 2023 | Construction CLASS - 2 REISSUE #35665262Y OBSERVED BSMT THROUGHOUT LACKING FIRESTOPPING. BOILER ROOM AREA. REMEDY: PROVIDE/MAINTAIN FIRE STOPPING #35663459Z | Nov 2, 2023 POP/IN-VIO | $0 |
| Jul 13, 2022 | Construction CLASS - 2 REISSUE35433635P DOI6.11.19 FAILURE TO MAINTAIN NBLFDG IN CODECOMPLIANT MANNER NO FIRESTOPPING PER BC712.3.27-345 ATOI I OBSERVED THAT&NOTEDBSMT THRUOUT LACKING FIRESTOPPING NEAR BOILERRM AREA IN ROOF AREA&WALL #35665262Y | Oct 13, 2022 POP/IN-VIO | $0 |
| Jun 29, 2021 | Local Law CLASS - 2 RE-ISSUE #35486997H FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER NOTED AT TIME OF INSPECTION OBSERVED AT BASEMENT LEVEL THROUGHOUT LACKING (OX KIKO) STOPPING VIOLATION #35456997L ISSUED 05/22/20 FOR MU #35577469L | Jul 22, 2021 POP/IN-VIO | $0 |
| Jan 15, 2020 | Elevators CLASS - 1 97X10: (97-X-10) ENTIRE DEVICE INOPERATIVE. REMEDY: RETURN DEVICE TO SERVICE #38272519M | Apr 16, 2020 POP/IN-VIO | $0 |
| Jun 11, 2019 | Construction CLASS - 2 REISSUE#35329596L DATE OF ISSUE 4/26/18 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER NO FIRE STOPPING PER BC 712.3;27-345 AT BSMT(THROUGHOUT) LACKING FIRE STOPPING NEAR BOILER ROOM AREA IN ROOF&WALL. R #35433635P | Sep 12, 2019 POP/IN-VIO | $0 |
| Apr 26, 2018 | Construction CLASS - 2 RE-ISSUE #35236072H FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER NO FILE STOPPING PER BC 712.3;27-345 @BSMT (THROUGHT) LACKING FIRE STOPPING REM:PROVIDE/MAINTAIN FIRE STOPPING. #35329596L | Aug 30, 2018 POP/IN-VIO | $0 |
| Apr 19, 2017 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NO FIRE STOPPING AS PER BC 712.3;27.343 AT BASEMENT THRU-OUT/& NEAR BOILER ROOM AREA. REMEDY: REPAIR/PROVIDE FIRE STOPPING. #35236072H | Jun 1, 2017 POP/IN-VIO | $0 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Oct 29, 2026 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Active |
| Oct 29, 2026 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Open |
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 13, 2026, 3:03 PM ET. BBL 1022290012.