Brooklyn · Block 4690 · Lot 73 · 11212

506 East 94 Street

2 floors · 3 apartments · 2,400 sq ft · built 1920 · class C0 · owner of record: 50694 Realty Llc

26open violations
$61,250ECB/OATH penalties owed
2HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2025-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 43 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 43 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 59 days
Annual
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 17 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 408 days
Next cycle year 2027

Open violations

ECB / OATH (15) · $61,250 owed
IssuedViolationHearingBalance
Oct 28, 2026Site Safety CLASS - 1
AT THE TIME OF MY INSPECTION OF A 9 STORY NEW BUILDING, I OBSERVED BUILDING AT BULK HEAD LEVEL, WITH ROOF PROTECTION ON TOP OF ADJACENT PROPERTY AND NEEDLE BEAMS AT EXPOSURE #2,UPON REQUEST FOR ACCESS AGREEMENT
#39561232M
Jan 6, 2027
PENDING
$2,500
Oct 28, 2026Construction CLASS - 1
28-110.2 AT THE TIME OF MY INSPECTION OF A 9 STORY NEW BUILDING, I OBSERVED BUILDING AT BULK HEAD LEVEL, UPON REVIEW OF THE DEPARTMENT RECORDS IT REVEAL THAT SITE SAFETY PLAN ONLY APPROVED TO THE FOUNDATION LEV
#39561231K
Jan 6, 2027
PENDING
$2,500
Oct 28, 2026Construction CLASS - 1
AT THE TIME OF MY INSPECTION OF A 9 STORY NEW BUILDING, I OBSERVED BUILDING AT BULK HEAD LEVEL, UPON REVIEW OF THE DEPARTMENT RECORDS IT REVEAL THAT SITE SAFETY PLAN ONLY APPROVED TO THE FOUNDATION LEVEL BUT JO
#39561233Y
Jan 6, 2027
PENDING
$10,000
Oct 27, 2026Unknown CLASS - 1
BC 3307.2.1 AT THE TIME OF MY INSPECTION, I OBSERVED AT EXPOSURE #1 CONCRETE PUMP TRUCK ON STREET OCCUPYING 11 FEET OF ROAD WAY, UPON REVIEW OF THE DOT PERMIT IT REVEAL THAT 5 FEET PEDESTRIAN WALKWAY SHOULD MAI
#39561160M
Jan 6, 2027
PENDING
$5,000
Oct 27, 2026Construction CLASS - 1
AT THE TIME OF MY INSPECTION 9 STORY NEW BUILDING,I OBSERVED AT EXPOSURE #1&2 NEEDLE BEAMS INSTALLED WITH SUPPORTED PIPE SCAFFOLD ON TOP, UPON REVIEW OF THE APPROVED PLANS IT REVEAL THAT SUPPORTING JACKS SHOULD
#39561161Y
Jan 6, 2027
PENDING
$2,500
Oct 27, 2026Unknown CLASS - 1
BC 3305.3.6.1.2 AT THE TIME OF MY INSPECTION OF A 9 STORY NEW BUILDING, I OBSERVED RESHORES JACKS ON THE 7&8 FLOORS CLOSE TO THE PERIMETER OF THE BUILDING THAT WERE NOT SECURED, FAILURE TO SECURE RESHORES JACKS
#39561164J
Jan 6, 2027
PENDING
$5,000
Oct 27, 2026Site Safety CLASS - 1
BC 3307.2.1 AT THE TIME OF MY INSPECTION OF A 9 STORY NEW BUILDING, I OBSERVED AT EXPOSURE #1 CONCRETE WASHOUT BOX MADE OF PLYWOOD AND 2X4, UPON REQUEST FOR DESIGN DRAWINGS NONE WAS PRESENTED OR AT JOBSITE, FAI
#39561162X
Jan 6, 2027
PENDING
$2,500
Oct 27, 2026Unknown CLASS - 1
BC 3307.2.1 AT THE TIME OF MY INSPECTION, I OBSERVED AT EXPOSURE #1 CONCRETE PUMP TRUCK ON STREET OCCUPYING 11 FEET OF ROAD WAY, UPON REVIEW OF THE DOT PERMIT IT REVEAL THAT WORKING HOURS IS FROM 9AM TO 4PM AND
#39561163H
Jan 6, 2027
PENDING
$5,000
Oct 23, 2026Construction CLASS - 2
ATI OBSERVED; AN ACTIVE SITE FOR 9-STORY NEW BUILDING, EGRESS NOT MAINTAINED AS PER CODE. OBSERVED UNUSED SCAFFOLD MATERIALS, PIPES, WOODEN PANELS AND OTHER FOREIGN MATERIALS STORED ON DIFFERENT FLOORS INSIDE,
#39560996H
Jan 6, 2027
PENDING
$1,250
Oct 17, 2026Unknown CLASS - 2
WORK OR STORAGE ZONE AS PE BC 3307.4.7 AT THE TIME OF INSPECTION ON A NON ACTIVE JOB SITE , AT BUILDING FRONT EXPOSURE 1 INADEQUATE STORAGE ZONE BARRIERS FALLING DOWN NOT FILLED OR INTERLOCKED AND EQUIPMENT S
#39560706K
Dec 23, 2026
PENDING
$2,500
Sep 15, 2026Construction CLASS - 1
@ACTIVE SITE IN 2ND FL STRUCTURE PHASE OBSERVE STREETS WORK&STORAGE ZONE IN USE W/ ADDITIONAL KNUCKLE BOOM TRUCK IN USE TO DELIVERY SITES STRUCTURAL RELATED MATERIAL NOT COMPLY WITH PARTIAL STOP WORK ORDER COMP
#39559185X
Nov 25, 2026
$10,000
Sep 12, 2026Unknown CLASS - 1
NOTE: AT THE TIME OF INSPECTION, AN INADEQUATE ROADWAY WORK/STORAGE ZONE WAS OBSERVED ADJACENT TO THE SIDEWALK WITH CONSTRUCTION MATERIALS AND MACHINERY NOT ENCLOSED WITH THE REQUIRED PROTECTIVE MEASURES AS PER
#39559114Z
Nov 18, 2026
$5,000
Sep 12, 2026Unknown CLASS - 2
NOTE: AT TIME OF INSPECTION, I OBSERVED THAT THE SIDEWALK IS CLOSED, UPON REVIEWING DOT RECORDS IT WAS NOTED THAT NO PERMIT WAS ISSUED FOR THE SIDEWALK CLOSURE CONTRARY TO 3307.2.1. CREATING A HAZARD AND OBSTRU
#39559115K
Nov 18, 2026
$2,500
Aug 26, 2026Construction CLASS - 1
AT THE TIME OF INSPECTION OF THE 9-STORY NEW BUILDING, I OBSERVED THAT THE EARTHWORK WAS COMPLETED. FURTHER RESEARCH OF THE DOB RECORDS SHOWED THAT NO NOTIFICATION OF COMMENCEMENT HAD BEEN PROVIDED TO THE DOB P
#39558401R
May 20, 2027
$2,500
Aug 26, 2026Construction CLASS - 1
DURING THE INSPECTION OF A 9STORY NB AT AN ACTIVE JOB SITE, IT WAS OBSERVED THAT TIMBER SOLDIER POSTS WITH 3 INCH TIMBER LAGGING, RAKERS WITH HEEL BLOCKS WERE NOT INSTALLED ACCORDING TO THE APPROVED SOE (SUPPO
#39558396L
May 20, 2027
PENDING
$2,500
DOB (1)
IssuedViolationStatus
Oct 30, 2026CONSTRUCTION
ATOI, PURSUANT TO THE BOROUGH COMMISSIONER'S DIRECTIVE THAT ALL WORK UNDER JOB #B01295753 MUST STOP DUE TO FAILURE TO OBTAIN A WRITTEN ACCESS AGREEMENT WITH THE ADJOINING PROPERTY AT 508-510 EAST 94TH STREET, AS REQUIRED BY NYC BUILDING CODE 3309.2, TO ENSURE PROTECTION OF ADJOINING PROPERTY. FULL S
#26-02498
DOB VIOLATION - ACTIVE
DOB NOW Safety (2)
IssuedViolationStatus
Jan 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle D (premises is in Community District 17)
Active
Jan 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle D (premises is in Community District 17)
Active
HPD (12) · C 2 · B 2 · A 6
IssuedClassViolationCorrect by
Nov 19, 2025I§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R—
Jan 16, 2024I§ 27-2142 ADM CODE APTS HAVE BEEN VACATED BY THIS DEPARTMENT AND CANNOT BE REOCCUPIED UNTIL SO ORDERED AFTER PROOF OF COMPLIANCE FOR APTS AT CELLAR AT WEST UNDER VACATE #246833—
May 4, 2026A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Aug 7, 2026
Jun 9, 2025A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Sep 12, 2025
Apr 9, 2024A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Jul 13, 2024
Jan 15, 2024CApt BSMT · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT BSMT, 1st APARTMENT FROM SOUTH AT WESTFeb 10, 2024
Jan 11, 2024B§ 27-2081 ADM CODE DISCONTINUE USE OF ROOMS FOR LIVING, DISCONNECT PLUMBING FIXTURES AND PROPERLY SEAL PIPE CONNECTIONS WATERCLOSET, WASHBASIN,BATHTUB AND KITCHEN SINK AT CELLARFeb 15, 2024
Jan 11, 2024B§ 27-2070 ADM CODE DISCONTINUE UNLAWFUL COOKING SPACE OR FILE PLANS AND APPLICATION WITH THIS DEPARTMENT TO LEGALIZE SAME, IF LAWFULLY FEASIBLE, AT RANGE AT CELLARFeb 15, 2024
Jan 8, 2024CApt BASEME · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE 1st ROOM FROM EAST LOCATED AT APT BASEME, 1st APARTMENT FROM SOUTH AT WESTFeb 3, 2024
Mar 22, 2023A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Jun 25, 2023
Feb 24, 2022A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.May 30, 2022
Apr 8, 2021A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Jul 12, 2021

Issued in the last 120 days

DateSourceWhatNow
Oct 30, 2026DOBCONSTRUCTION: ATOI, PURSUANT TO THE BOROUGH COMMISSIONER'S DIRECTIVE THAT ALL WORK UNDER JOB #B01295753 MUST STOP DUE TO FAILURE TO OBTAIN A WRITTEN ACCESS AGREEMENT WITH THE ADJOINING PROPERTY AT 508-510 EAST 94TH STREET, AS REQUIRED BY NYC BUILDING CODE 3309.2, TO ENSURE PROTECTION OF ADJOINING PROPERTY. FULL SOpen
Oct 28, 2026ECBSite Safety: AT THE TIME OF MY INSPECTION OF A 9 STORY NEW BUILDING, I OBSERVED BUILDING AT BULK HEAD LEVEL, WITH ROOF PROTECTION ON TOP OF ADJACENT PROPERTY AND NEEDLE BEAMS AT EXPOSURE #2,UPON REQUEST FOR ACCESS AGREEMENTOpen
Oct 28, 2026ECBConstruction: 28-110.2 AT THE TIME OF MY INSPECTION OF A 9 STORY NEW BUILDING, I OBSERVED BUILDING AT BULK HEAD LEVEL, UPON REVIEW OF THE DEPARTMENT RECORDS IT REVEAL THAT SITE SAFETY PLAN ONLY APPROVED TO THE FOUNDATION LEVOpen
Oct 28, 2026ECBConstruction: AT THE TIME OF MY INSPECTION OF A 9 STORY NEW BUILDING, I OBSERVED BUILDING AT BULK HEAD LEVEL, UPON REVIEW OF THE DEPARTMENT RECORDS IT REVEAL THAT SITE SAFETY PLAN ONLY APPROVED TO THE FOUNDATION LEVEL BUT JOOpen
Oct 27, 2026ECBUnknown: BC 3307.2.1 AT THE TIME OF MY INSPECTION, I OBSERVED AT EXPOSURE #1 CONCRETE PUMP TRUCK ON STREET OCCUPYING 11 FEET OF ROAD WAY, UPON REVIEW OF THE DOT PERMIT IT REVEAL THAT 5 FEET PEDESTRIAN WALKWAY SHOULD MAIOpen
Oct 27, 2026ECBConstruction: AT THE TIME OF MY INSPECTION 9 STORY NEW BUILDING,I OBSERVED AT EXPOSURE #1&2 NEEDLE BEAMS INSTALLED WITH SUPPORTED PIPE SCAFFOLD ON TOP, UPON REVIEW OF THE APPROVED PLANS IT REVEAL THAT SUPPORTING JACKS SHOULDOpen
Oct 27, 2026ECBUnknown: BC 3305.3.6.1.2 AT THE TIME OF MY INSPECTION OF A 9 STORY NEW BUILDING, I OBSERVED RESHORES JACKS ON THE 7&8 FLOORS CLOSE TO THE PERIMETER OF THE BUILDING THAT WERE NOT SECURED, FAILURE TO SECURE RESHORES JACKSOpen
Oct 27, 2026ECBSite Safety: BC 3307.2.1 AT THE TIME OF MY INSPECTION OF A 9 STORY NEW BUILDING, I OBSERVED AT EXPOSURE #1 CONCRETE WASHOUT BOX MADE OF PLYWOOD AND 2X4, UPON REQUEST FOR DESIGN DRAWINGS NONE WAS PRESENTED OR AT JOBSITE, FAIOpen
Oct 27, 2026ECBUnknown: BC 3307.2.1 AT THE TIME OF MY INSPECTION, I OBSERVED AT EXPOSURE #1 CONCRETE PUMP TRUCK ON STREET OCCUPYING 11 FEET OF ROAD WAY, UPON REVIEW OF THE DOT PERMIT IT REVEAL THAT WORKING HOURS IS FROM 9AM TO 4PM ANDOpen
Oct 23, 2026ECBConstruction: ATI OBSERVED; AN ACTIVE SITE FOR 9-STORY NEW BUILDING, EGRESS NOT MAINTAINED AS PER CODE. OBSERVED UNUSED SCAFFOLD MATERIALS, PIPES, WOODEN PANELS AND OTHER FOREIGN MATERIALS STORED ON DIFFERENT FLOORS INSIDE,Open
Oct 17, 2026ECBUnknown: WORK OR STORAGE ZONE AS PE BC 3307.4.7 AT THE TIME OF INSPECTION ON A NON ACTIVE JOB SITE , AT BUILDING FRONT EXPOSURE 1 INADEQUATE STORAGE ZONE BARRIERS FALLING DOWN NOT FILLED OR INTERLOCKED AND EQUIPMENT SOpen
Sep 15, 2026ECBConstruction: @ACTIVE SITE IN 2ND FL STRUCTURE PHASE OBSERVE STREETS WORK&STORAGE ZONE IN USE W/ ADDITIONAL KNUCKLE BOOM TRUCK IN USE TO DELIVERY SITES STRUCTURAL RELATED MATERIAL NOT COMPLY WITH PARTIAL STOP WORK ORDER COMPClosed
Sep 12, 2026ECBUnknown: NOTE: AT THE TIME OF INSPECTION, AN INADEQUATE ROADWAY WORK/STORAGE ZONE WAS OBSERVED ADJACENT TO THE SIDEWALK WITH CONSTRUCTION MATERIALS AND MACHINERY NOT ENCLOSED WITH THE REQUIRED PROTECTIVE MEASURES AS PERClosed
Sep 12, 2026ECBUnknown: NOTE: AT TIME OF INSPECTION, I OBSERVED THAT THE SIDEWALK IS CLOSED, UPON REVIEWING DOT RECORDS IT WAS NOTED THAT NO PERMIT WAS ISSUED FOR THE SIDEWALK CLOSURE CONTRARY TO 3307.2.1. CREATING A HAZARD AND OBSTRUClosed
Aug 26, 2026ECBConstruction: AT THE TIME OF INSPECTION OF THE 9-STORY NEW BUILDING, I OBSERVED THAT THE EARTHWORK WAS COMPLETED. FURTHER RESEARCH OF THE DOB RECORDS SHOWED THAT NO NOTIFICATION OF COMMENCEMENT HAD BEEN PROVIDED TO THE DOB PClosed
Aug 26, 2026ECBConstruction: DURING THE INSPECTION OF A 9STORY NB AT AN ACTIVE JOB SITE, IT WAS OBSERVED THAT TIMBER SOLDIER POSTS WITH 3 INCH TIMBER LAGGING, RAKERS WITH HEEL BLOCKS WERE NOT INSTALLED ACCORDING TO THE APPROVED SOE (SUPPOOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 18, 2026, 12:59 PM ET. BBL 3046900073.

Look up another building