3 floors · 4 apartments · 6,888 sq ft · built 1930 · class S4 · owner of record: The Progressive Glorious Church Of Chris T
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 60 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 60 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 76 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 304 days | Registered through 2027-09-01 |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1156 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Apr 4, 2009 | Construction CLASS - 1 SEC.28-201.1. FAILURE TO COMPLY W/THE COMMISSIONERS ORDER TO OBTAIN A PERMIT VIS VIOLATION #34686614P IN THAT A 6 FAMILY DWELLING HAS BEEN CNVERTED TO A CHURCH & SRO'S RESIDENCE W/O A PERMIT.REMEDY:COMPLY W/# #34770407Y | Oct 28, 2009 WRITTEN OFF | $0 |
| Apr 4, 2009 | Construction CLASS - 1 OCCUPANCY CONTRARY TO THAT OF C OF O #176448 WHICH INDICATE THAT THE 1FL IS TO BE OCCUPIED BY 2"CLASS A" APARTMENTS, 1FL NOW OCCUPIED AS A CHURCH.REMEDY:DISCONTINUE ILLEGAL USE OR AMEND C OF O. #34770408X | Oct 28, 2009 WRITTEN OFF | $0 |
| Sep 17, 2008 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTE: AT THE CELLAR LEVEL THE BOILER ROOM DOES NOT CONFORMING TO CODE: (A) MOST OF THE BOILER RM CEILING IS MISSING, EXPOSING THE WOOD JOINTS. (B) THE FR #34686613N | Apr 22, 2009 WRITTEN OFF | $0 |
| Sep 17, 2008 | Construction CLASS - 1 WORK W/O A PERMIT NOTED C OF O 176448 ISSUED ON 8/14/1961 INDICATED THE BLDG TO BE OCCUPIED AS 6 FAMILY DWELLING (2 FAMILIES EACH FL) NOW THE BLDG ALTERED FOR OCCUPANCY AS 1ST FL CHURCH 2ND FL 1 APT 2 ROOMS AND #34686614P | Apr 22, 2009 WRITTEN OFF | $0 |
| Sep 17, 2008 | Construction CLASS - 1 OCCUPANCY CONTRARY TO THAT ALLOWED BY C/O. NOTED: C/O 176448 INDICATEDRESIDENCE TO BE LEGALLY APPROVED FOR 6 FAMILY. RESIDENCE IS NOW ALTERED FOR OCCUPANCY AS A MULTI-DWELLING. AT 1ST FL. AS CHURCH 2ND FL 2 RMS #34686615R | Apr 22, 2009 WRITTEN OFF | $0 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Sep 18, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle B (premises is in Community District 2) | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| May 6, 2026 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Aug 9, 2026 |
| Aug 30, 2007 | B | SECTION 300, 301, 302, M/D LAW FILE PLANS AND OBTAIN A CERTIFICATE OF OCCUPANCY TO LEGALIZE THE FOLLOWING ALTERATION OR RESTORE PREMISES TO PRIOR LEGAL CONDITION OCCUPANCY DECREASED FROM 6 CLASS A APARTMENTS TO 1 CLASS A APARTMENT | Oct 4, 2007 |
| Aug 30, 2007 | C | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT KITCHEN FIXTURE OF 3 STY APT. | Sep 5, 2007 |
| Aug 30, 2007 | C | Apt 3 · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK CEILING OVER ROOM SECOND FROM WEST AT NORTH AND WEST ROOM CEILING 3 STY SOUTHWEST APT 3 ER1 , SECTION '' '' | Sep 5, 2007 |
| Aug 30, 2007 | C | Apt 3 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING OVER ROOM SECOND FROM WEST AT NORTH AND WEST ROOM CEILING 3 STY SOUTHWEST APT 3 ER1 , SECTION '' '' | Sep 5, 2007 |
| Aug 30, 2007 | C | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD PLASTER AND PAINT IN HANGING FROM CEILING CENTER ROOM 3 STY FLOOR APT. | Sep 5, 2007 |
| Aug 30, 2007 | C | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING 2 ROOM FROM REAR 3 FLOOR APT. | Sep 5, 2007 |
| Aug 30, 2007 | C | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING KEY OPERATED DOUBLE CYLINDER LOCK AT ENTRANCE DOOR TO 3 STY APT. | Sep 5, 2007 |
| Sep 5, 1968 | I | D26-35.01 ADM CODE THE PREMISES HAVE BEEN VACATED BY AN ORDER OF THIS DEPARTMENT AND CANNOT BE REOCCUPIED EXCEPT FOR CARETAKER UNTIL A NEW CERTIFICATE OF OCCUPANCY HAS BEEN OBTAINED. | Nov 4, 1968 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 1, 2026, 3:07 PM ET. BBL 3019780028.