Brooklyn · Block 789 · Lot 38 · 11220

5002 3 Avenue

4 floors · 6 apartments · 7,081 sq ft · built 1931 · class S9 · owner of record: Konstantinou, Loukas

12open violations
$1,250ECB/OATH penalties owed
6HPD class C (immediately hazardous)
67dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 67 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 67 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 83 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 311 days
Registered through 2027-09-01
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1163 days
Next cycle year 2029

Open violations

ECB / OATH (1) · $1,250 owed
IssuedViolationHearingBalance
Mar 8, 2026Construction CLASS - 2
INOPERABLE EMERGENCY EXIT LIGHTING OBSERVED AT DRINKING ESTABLISHMENT ON FIRST FLOOR AT BOTH EXIT DOORS. AS PER BC 1006.1;27-542., REPAIR AND/OR REPLACE LIGHTING; REPAIR LIGHTS.
#39179572L
Nov 9, 2026
PENDING
$1,250
DOB (0)

None open.

DOB NOW Safety (1)
IssuedViolationStatus
Sep 18, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle B (premises is in Community District 7)
Active
HPD (10) · C 6 · B 2 · A 2
IssuedClassViolationCorrect by
Mar 28, 2024CApt 2R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHApr 23, 2024
Mar 28, 2024CApt 2R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHApr 23, 2024
Mar 28, 2024CApt 2R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHApr 23, 2024
May 5, 2023C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE BUILDING FRONT ENTRANCE , 1st STORYMay 19, 2023
Nov 8, 2021BApt 5 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX. 8 SQ.FT. AT THE CEILING IN THE BATHROOM LOCATED AT APT 5, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 14427859 ISSUED 07-JUL-21 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-201Dec 13, 2021
Nov 8, 2021BApt 5 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX. 1 SQ.FT. AT THE CEILING IN THE KITCHEN LOCATED AT APT 5, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 14427871 ISSUED 07-JUL-21 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017Dec 13, 2021
Jul 13, 2021CApt 4R · § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE IN THE ENTRANCE LOCATED AT APT 4R, 4th STORY, APARTMENT AT EASTAug 8, 2021
Jul 12, 2021AApt 1 · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOWER SASH (STUCK IN SHUT POSITION) AT THE WINDOW AT NORTH IN THE KITCHEN LOCATED AT APT 1, 1st STORY, APARTMENT AT WESTOct 15, 2021
Jul 12, 2021AApt 1 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND SOUTH WALL IN THE 4th ROOM FROM NORTH LOCATED AT APT 1, 1st STORY, APARTMENT AT WESTOct 15, 2021
Jul 12, 2021CApt 1 · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE OF THE LOWER SASH AT THE 1ST., WINDOW FROM EAST AT SOUTH, IN THE 4th ROOM FROM NORTH LOCATED AT APT 1, 1st STORY, APARTMENT AT WESTJul 18, 2021

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 25, 2026, 12:09 PM ET. BBL 3007890038.

Look up another building