8 floors · 33 apartments · 84,634 sq ft · built 2013 · class RM · owner of record: Unavailable Owner
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 44 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 44 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 44 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 60 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 84,634 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 165 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 165 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 288 days | Registered through 2027-09-01 |
| Facade inspection report (Cycle 10C) Applies Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. Agency page | Feb 21, 2029 in 827 days | Filing window not open yet |
| Energy audit and retro-commissioning (2032) Likely applies Local Law 87 · Calendar year 2032 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 692). Agency page | Dec 31, 2032 in 2236 days | Next due 2032 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-11-09 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 6, 2026 | Plumbing CLASS - 1 FUMES ENTERING APARTMENTS FROM WOOD BURNING FIREPLACE; MC MISC, COMPLY WITH NOTICE OF VIOLATION; PERFORM A SMOKE TEST AS PER NYC MECHANICAL CODE 810 TO DETERMINE THE INTEGRITY AND TIGHTNESS OF THE FIREPLACE LIN #39207298N | Dec 17, 2026 PENDING | $2,500 |
| Oct 6, 2026 | Plumbing CLASS - 1 FUMES FROM WOOD-BURNING FIREPLACES ENTERING APARTMENTS 5A AND 7A. PERFORM A SMOKE TEST PER NYC MECHANICAL CODE 810 TO DETERMINE THE INTEGRITY AND TIGHTNESS OF THE FIREPLACE LINER WITHIN THE CHASE TO THE GARDEN #39209960H | Jan 7, 2027 PENDING | $2,500 |
| Oct 6, 2026 | Plumbing CLASS - 1 FUMES ENTERING APARTMENT FROM WOOD BURNING FIRE PLACE; MC MISC, COMPLY WITH NOTICE OF VIOLATION; PERFORM A SMOKE TEST AS PER NYC MECHANICAL CODE 810 TO DETERMINE THE INTEGRITY AND TIGHTNESS OF THE FIREPLACE LIN #39207308H | Dec 17, 2026 PENDING | $2,500 |
| Oct 6, 2026 | Plumbing CLASS - 1 FUMES ENTERING APARTMENT FROM WOOD BURNING FIRE PLACE; MC MISC, COMPLY WITH NOTICE OF VIOLATION; PERFORM A SMOKE TEST AS PER NYC MECHANICAL CODE 810 TO DETERMINE THE INTEGRITY AND TIGHTNESS OF THE FIREPLACE LIN #39207290Z | Dec 17, 2026 PENDING | $2,500 |
| Oct 6, 2026 | Plumbing CLASS - 1 FUMES ENTERING APARTMENT FROM WOOD BURNING FIRE PLACE; MC MISC, COMPLY WITH NOTICE OF VIOLATION; PERFORM A SMOKE TEST AS PER NYC MECHANICAL CODE 810 TO DETERMINE THE INTEGRITY AND TIGHTNESS OF THE FIREPLACE LIN #39207303Z | Dec 17, 2026 PENDING | $2,500 |
| Jun 5, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING FACADE WALL"S" AND APPURTENANCES. NOTE: AT THE TIME OF INSPECTION, I OBSERVED AT EX #1, NORTH ELEVATION CRACKEDSTORE BETWEEN 7TH AND 8TH FLOOR. AT EX #2, EAST ELEVATION, CRACKED STO #35729620P | Feb 26, 2027 PENDING | $2,500 |
| Mar 23, 2026 | Construction CLASS - 2 ATOI, OBSERVED THAT UNDERSIDE OF UNIT PH A BALCONY ABOVE APT 7A HAS SEVERAL AREAS OF WATER DAMAGE AND RUST. PH A BLOCK 692 LOT 1009, REPAIR AND/OR REPLACE; REPAIR WATER AND RUST DAMAGE AT UNDERSIDE OF UNIT PH A #39181470N | May 28, 2026 DEFAULT | $6,250 |
| Feb 20, 2026 | Plumbing CLASS - 2 PERFORM A SMOKE TEST TO DETERMINE THE TIGHTNESS OF THE CHIMNEY AS PER MC 2008 810.3; MC-MISC.,, COMPLY WITH NOTICE OF VIOLATION; PROVIDE PROPER DOCUMENTATION AS REQUESTED FOR CHIMNEY. #39177969K | Jan 12, 2027 PENDING | $1,250 |
| Issued | Violation | Status |
|---|---|---|
| Feb 3, 2025 | CONSTRUCTION DUE TO CIRCUMSTANCES BEYOND CONTROL: OBSERVED WATER LEAKING FROM PHA PATIO ABOVE WITH LARGE GAP SHOWING NO MEMBRANE & EXPOSED METAL STUDS ONTO APT.7A PATIO LEAVING MOLD/ RESIDUE ON FLOOR. #25-00195 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Apr 24, 2023 | A | Apt 7A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK OVER THE CEILING IN THE TERRACE LOCATED AT APT 7A, 7th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Jul 28, 2023 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 6, 2026 | ECB | Plumbing: FUMES ENTERING APARTMENTS FROM WOOD BURNING FIREPLACE; MC MISC, COMPLY WITH NOTICE OF VIOLATION; PERFORM A SMOKE TEST AS PER NYC MECHANICAL CODE 810 TO DETERMINE THE INTEGRITY AND TIGHTNESS OF THE FIREPLACE LIN | Open |
| Oct 6, 2026 | ECB | Plumbing: FUMES FROM WOOD-BURNING FIREPLACES ENTERING APARTMENTS 5A AND 7A. PERFORM A SMOKE TEST PER NYC MECHANICAL CODE 810 TO DETERMINE THE INTEGRITY AND TIGHTNESS OF THE FIREPLACE LINER WITHIN THE CHASE TO THE GARDEN | Open |
| Oct 6, 2026 | ECB | Plumbing: FUMES ENTERING APARTMENT FROM WOOD BURNING FIRE PLACE; MC MISC, COMPLY WITH NOTICE OF VIOLATION; PERFORM A SMOKE TEST AS PER NYC MECHANICAL CODE 810 TO DETERMINE THE INTEGRITY AND TIGHTNESS OF THE FIREPLACE LIN | Open |
| Oct 6, 2026 | ECB | Plumbing: FUMES ENTERING APARTMENT FROM WOOD BURNING FIRE PLACE; MC MISC, COMPLY WITH NOTICE OF VIOLATION; PERFORM A SMOKE TEST AS PER NYC MECHANICAL CODE 810 TO DETERMINE THE INTEGRITY AND TIGHTNESS OF THE FIREPLACE LIN | Open |
| Oct 6, 2026 | ECB | Plumbing: FUMES ENTERING APARTMENT FROM WOOD BURNING FIRE PLACE; MC MISC, COMPLY WITH NOTICE OF VIOLATION; PERFORM A SMOKE TEST AS PER NYC MECHANICAL CODE 810 TO DETERMINE THE INTEGRITY AND TIGHTNESS OF THE FIREPLACE LIN | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 17, 2026, 2:31 PM ET. BBL 1006927502.