Manhattan · Block 1474 · Lot 31 · 10065

500 East 62 Street

20 floors · 132,966 sq ft · built 1974 · class HB · owner of record: Plaza East Hotel, Llc

11open violations
$8,125ECB/OATH penalties owed
2HPD class C (immediately hazardous)
43dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 43 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 43 days
Keep the report on file (not filed with DOB)
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $216,000 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2027
in 95 days
No Cycle 10 report on record yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 132,966 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 164 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 164 days
Annual filing
Energy audit and retro-commissioning (2034) Likely applies
Local Law 87 · Calendar year 2034
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1474). Agency page

Dec 31, 2034
in 2965 days
Next due 2034
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-06-10 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (7) · $8,125 owed
IssuedViolationHearingBalance
Aug 12, 2026Elevators CLASS - 2
CLASS 2: 1. DROP CEILING SECTION LEADING TO TOP EXIT (ESCAPE HATCH) UNLOCKED AND NOT SECURED AS REQUIRED. AS PER ASME A17.1 2.14. REMEDY: SECURE DROP CEILING SECTION AND VERIFY PROPER LOCKING. 2. TOP OF CAR OPE
#39200256N
Dec 3, 2026
$625
Aug 12, 2026Elevators CLASS - 1
CLASS 1: CLASS 1: 1. PIT DOOR UNLOCKED AND CAN BE OPENED, EXPOSING PERSONNEL TO HAZARDOUS CONDITIONS. AS PER ASME A17.1 2.12. REMEDY FOR CLASS 1: REPAIR/INSTALL A LOCK AND ENSURE THE DOOR STAYS LOCKED AT ALL TI
#39200255L
Dec 3, 2026
$1,250
Aug 12, 2026Elevators CLASS - 1
1. DROP CEILING SECTION LEADING TO TOP EXIT DOOR (ESCAPE HATCH) AND THE ESCAPE HATCH BOTH UNLOCKED, PROVIDING UNRESTRICTED ACCESS TO OPEN HOISTWAY AND CREATING A HAZARDOUS CONDITION. AS PER ASME A17.1 2.14. REM
#39200257P
Dec 3, 2026
$1,250
May 1, 2026Unknown CLASS - 2
FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION. AS NOTED: AT TIME OF INSPECTION ON AN OCCUPIED PARKING STRUCTURE CONSISTING OF 2 LEVELS(CELLAR LEVEL AND SUBCELLAR LEVEL), OBSERVED SPALLING STUCCO CONCR
#35729829X
Mar 5, 2027
PENDING
$1,250
Feb 20, 2026Construction CLASS - 2
NO ACCESS. NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 FAILURE-TO-MAINTAIN VIOLATION #357170152 ISSUED 4/13/2025 FOR SPALLING AND CRACKS AT CONCRETE SLABS AND BEAMS, AND AT THE RAMP BETWEEN CELLAR AND DRIV
#39178029P
Jan 22, 2027
$1,250
Apr 13, 2025Unknown CLASS - 1
FAILURE TO MAINTAIN PARKING STRUCTURE INSAFE CONDITION. AS NOTED AT TIME OF INSPECTION ON AN OCCUPIED PARKING STRUCTURE CONSISTING OF 2 LEVELS(CELLAR LEVEL AND SUBCELLAR LEVEL), OBSERVED SPALLING/CRACKED CONCRE
#35717015Z
Mar 19, 2027
$2,500
Oct 1, 2024Construction CLASS - 1
FAILURE TO SUBMIT THE REQUIRED PARKING STRUCTURE INITIAL OBSERVATION REPORT FOR AN EXISTING PARKING STRUCTURE OR A PERIODIC INSPECTION OF A PARKING STRUCTURE(PIPS)REPORT DOCUMENTING THE CONDITIONS OF PSID#M0000
#37030810J
Apr 3, 2025
IN VIOLATION
$0
DOB (2)
IssuedViolationStatus
Apr 13, 2025CONSTRUCTION
EMERGENCY WORK.AT TIME OF INSPCTN ON AN OCCUPIED PARKING STRCTRE CONSISTNG OF 1LEVEL(STREET LEVEL),OBSRVD HORIZNTL CRCK CNCRTE@WALLS@ EXP#4,CRCKD&SPALLNG CNCRTE@SLABS&BEAMS,EXPSD REBAR SLAB.IMMED EVAL BY QPSI.OWNR TO RTAIN A NYS REG DSGN PROF(RDP) TO DRCT&SUPERVISE THE IMMED INSTALLATION OF SFTY MEA
#PS10801JL
DOB VIOLATION - ACTIVE
Jan 22, 2025FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00032
DOB VIOLATION - ACTIVE
DOB NOW Safety (3)
IssuedViolationStatus
Sep 23, 2026Parking Structures FTF-PS-INITL
Failure to file parking structures compliance report by 12/31/2025 as required per 1 RCNY 103-13
Active
Oct 10, 2025Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction
Active
Jan 22, 2025AEUHAZ FTC-AEU-HAZ
Active
HPD (4) · C 2 · B 0 · A 2
IssuedClassViolationCorrect by
Oct 26, 2026C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM BOILER ROOM ENTRANCE DOOR FOR ROOF ENTRY LOCKED AT BOILER ROOMNov 1, 2026
Oct 26, 2026CApt 608 · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 608, 6th STORY, 1st APARTMENT FROM EAST AT SOUTHOct 26, 2026
Apr 29, 2026A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Aug 2, 2026
Jun 4, 2025A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Sep 7, 2025

Issued in the last 120 days

DateSourceWhatNow
Oct 26, 2026HPD C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM BOILER ROOM ENTRANCE DOOR FOR ROOF ENTRY LOCKED AT BOILER ROOMOpen
Oct 26, 2026HPD C§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 608, 6th STORY, 1st APARTMENT FROM EAST AT SOUTHOpen
Sep 23, 2026DOB SafetyParking Structures: Failure to file parking structures compliance report by 12/31/2025 as required per 1 RCNY 103-13Open
Aug 12, 2026ECBElevators: CLASS 2: 1. DROP CEILING SECTION LEADING TO TOP EXIT (ESCAPE HATCH) UNLOCKED AND NOT SECURED AS REQUIRED. AS PER ASME A17.1 2.14. REMEDY: SECURE DROP CEILING SECTION AND VERIFY PROPER LOCKING. 2. TOP OF CAR OPEClosed
Aug 12, 2026ECBElevators: CLASS 1: CLASS 1: 1. PIT DOOR UNLOCKED AND CAN BE OPENED, EXPOSING PERSONNEL TO HAZARDOUS CONDITIONS. AS PER ASME A17.1 2.12. REMEDY FOR CLASS 1: REPAIR/INSTALL A LOCK AND ENSURE THE DOOR STAYS LOCKED AT ALL TIClosed
Aug 12, 2026ECBConstruction: ATOI OBSERVED THROUGH OUT THE BUILDING PAINTED SPRINTER HEADS ON EVERY FLOOR SPRINKLER CAPS NEED TO BE REPLACED CONTRARY TO 903.3.3, REPAIR AND/OR REPLACEClosed
Aug 12, 2026ECBElevators: 1. DROP CEILING SECTION LEADING TO TOP EXIT DOOR (ESCAPE HATCH) AND THE ESCAPE HATCH BOTH UNLOCKED, PROVIDING UNRESTRICTED ACCESS TO OPEN HOISTWAY AND CREATING A HAZARDOUS CONDITION. AS PER ASME A17.1 2.14. REMClosed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 18, 2026, 2:32 AM ET. BBL 1014740031.

Look up another building