Bronx · Block 2261 · Lot 5 · 10454

500 East 134 Street

6 floors · 41,080 sq ft · built 1931 · class H9 · owner of record: 500 East 134th Owners Llc

3open violations
$2,810ECB/OATH penalties owed
0HPD class C (immediately hazardous)
164dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 43 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 41,080 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 164 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 164 days
Annual filing
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 774 days
Next cycle year 2028

Open violations

ECB / OATH (2) · $2,810 owed
IssuedViolationHearingBalance
Apr 28, 2026Elevators CLASS - 2
CLASS 2: HOIST CABLES SHOW SIGNS OF ROUGE/DEFECTIVE CONDITION. FIRE EXTINGUISHER PROVIDED IS CLASS B:C ONLY. MAINTENANCE LOG NOT UP TO DATE. CITY ID TAG ON CAR STATION UNREADABLE. TOP OF CAR JUNCTION BOX COVER
#39186325J
Jul 31, 2026
STIPULATION/IN-VIO
$310
Apr 28, 2026Construction CLASS - 1
OBSERVED IN LAUNDRY ROOM ON FIRST FLOOR 4IN PVC PIPE BEING USED ON ROOF DRAINS. WHICH IS CONTRARY TO CODE PC 701.9 PLASTIC PIPING AND FITTINGS SHALL NOT BE USED, REPAIR AND/REPLACE
#39186308H
Feb 19, 2027
PENDING
$2,500
DOB (1)
IssuedViolationStatus
Jan 13, 1997LOCAL LAW 10/81 - ELEVATOR

#01871
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 18, 2026, 5:38 AM ET. BBL 2022610005.

Look up another building