27 floors · 138,883 sq ft · built 1917 · class O4 · owner of record: Fifty East Forty Etc.
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 42 days | Keep the report on file (not filed with DOB) |
| Energy audit and retro-commissioning (2026) Likely applies Local Law 87 · Calendar year 2026 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1276). Agency page | Dec 31, 2026 in 42 days | Due this year |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 138,883 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 163 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 163 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1138 days | Next cycle year 2029 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-10-07 (Accepted). Agency page | On file | 2026 reports accepted |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $36,000 in late-filing or failure-to-file penalties. Agency page | On file | Cycle 10 filing on record: UNSAFE (2026-10-28) |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 10, 2026 | Unknown CLASS - 2 NOTE: AT TIME OF INSPECTION, I OBSERVED A TRASH TRUCK PARKED ON THE SIDEWALK WITHOUT ANY BARRIERS IN PLACE WHILE CONSTRUCTION DEBRIS IS BEING THROWN INTO THE BACK CREATING AN OBSTRUCTION FOR PEDESTRIANS AND VEH #39559005J | Nov 19, 2026 | $2,500 |
| Sep 10, 2026 | Unknown CLASS - 1 NOTE: AT THE TIME OF INSPECTION, I OBSERVED WORKERS THROWING WHITE DEBRIS BAGS FROM THE SIDEWALK SHED INTO A TRUCK AT EXPOSURE #4, CONTRARY TO 3303.5.2. THIS CREATES A HAZARDOUS CONDITION FOR PEDESTRIANS AS A D #39559004H | Nov 19, 2026 | $5,000 |
| Jun 17, 2024 | Construction CLASS - 2 27-929.1 FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER REPORT PREPARED BY A REGISTERED DESIGN PROFESSIONAL IN AN OFFICE BUILDING 100 FEET OR MORE IN HE #37028855K | Feb 6, 2025 IN VIOLATION | $0 |
| Feb 28, 2023 | Construction CLASS - 2 A.C.27-929.1,FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER REPORT PREPARED BY A REGISTERED DESIGN PROFESSIONAL IN AN OFFICE BUILDING 100' OR MORE IN HE #37025442Z | Dec 21, 2023 ADMIT/IN-VIO | $0 |
| Nov 1, 2021 | Construction CLASS - 2 27-929.1 FAILURE TO COMPLETE INSTALLATION OF FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE FINAL SPRINKLER REPORT PREPARED BY REGISTERED DESIGN PROFESSIONAL IN OFFICE BUILDING 100 FEET OR MORE IN HEIGHT IN EXIST #37022553H | Jul 21, 2022 IN VIOLATION | $0 |
| Mar 30, 2021 | Construction CLASS - 2 SEC. A.C 27-929.1,FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS & FILE A FINAL SPRINKLER REPORT PREPARED BY A REGISTERED DESIGN PROFESSIONAL IN AN OFFICE BLDG 100 FEET OR MORE IN #37020841N | Sep 30, 2021 IN VIOLATION | $0 |
| Mar 30, 2020 | Construction CLASS - 2 SEC. 27-929.1 AC 27-929.1 FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS & FILE A FINAL SPRINKLER REPORT PREPARED BY A REGISTERED DESIGN PROFESSIONAL BY 7/1/19,IN AN OFFICE BLDG #37018926J | Oct 29, 2020 IN VIOLATION | $0 |
| Nov 15, 2019 | Construction CLASS - 2 27-929.1 A.C. 27-929.1,FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER REPORT PREPARED BY A REGISTERED DESIGN PROFESSIONAL BY 7/1/19,IN AN OFFICE BUILDIN #37016542L | Feb 20, 2020 IN VIOLATION | $0 |
| Dec 6, 2011 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER NOTED THE FOLLOWING CONDITIONS:THE BLDGS CELLAR KNOWN AS LUCILLE ROBERTS HAS INADEQUATE SPRINKELR SYSTEM & NO CARBON MONOXIDE SMOKE DETECTORS.NOTED SOME SPRINKL #34937634X | Mar 8, 2012 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Sep 9, 2026 | CONSTRUCTION SHED NO LONGER CODE COMPLIANT DUE TO BEING HIT BY A CAR. DAMAGE TO 9 VERTICAL MEMBERS. #26-02169 | DOB VIOLATION - ACTIVE |
| Feb 18, 2022 | HAZARDOUS CONDITION (FACADE) CYCLE 9A UNSAFE REPORT FILED #910017 | DOB VIOLATION - ACTIVE |
| Feb 18, 2022 | FAILURE TO CORRECT SWARMP CONDITIONS (FACADE) CYCLE 9A FAILURE TO CORRECT SWARMP CONDITIONS #00296 | DOB VIOLATION - ACTIVE |
| Dec 1, 2021 | FAILURE TO POST ENERGY GRADE/SCORE FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 #2100689 | DOB VIOLATION - ACTIVE |
| Sep 3, 2019 | SPRINKLER FAILED TO FILE FINAL SPRINKLER REPORT BY JULY 1, 2019 #NRF00498 | DOB VIOLATION - ACTIVE |
| Sep 15, 2017 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2016 INSPECTION/TEST #02922 | DOB VIOLATION - ACTIVE |
| Sep 15, 2017 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2016 INSPECTION/TEST #02919 | DOB VIOLATION - ACTIVE |
| Sep 15, 2017 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2016 INSPECTION/TEST #02920 | DOB VIOLATION - ACTIVE |
| Sep 15, 2017 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2016 INSPECTION/TEST #02921 | DOB VIOLATION - ACTIVE |
| Sep 15, 2017 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2016 INSPECTION/TEST #02923 | DOB VIOLATION - ACTIVE |
| Oct 21, 2014 | HIGH PRESSURE BOILER #9028/523826 | DOB VIOLATION - ACTIVE |
| Mar 23, 2000 | ELEVATOR 1P10590 #9444/120948 | DOB VIOLATION - ACTIVE |
| Mar 23, 2000 | ELEVATOR #9444/120952 | DOB VIOLATION - ACTIVE |
| Mar 23, 2000 | ELEVATOR 1P10593 #9444/120951 | DOB VIOLATION - ACTIVE |
| Mar 23, 2000 | ELEVATOR 1P10591 #9444/120949 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 29, 2026 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Active |
| Oct 2, 2023 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Report | Active |
| Feb 18, 2022 | Facades FISPFCS CYCLE 9A FAILURE TO CORRECT SWARMP CONDITIONS | Active |
| Feb 18, 2022 | Facades FISPHAZ CYCLE 9A UNSAFE REPORT FILED | Active |
| Dec 1, 2021 | Energy Grade - LL33 FTP-EN-EGRDEA | Active |
| Sep 3, 2019 | Sprinklers FTF-SP-FINAL | Active |
| Sep 15, 2017 | Elevators EVCAT1 | Active |
| Sep 15, 2017 | Elevators EVCAT1 | Active |
| Sep 15, 2017 | Elevators EVCAT1 | Active |
| Sep 15, 2017 | Elevators EVCAT1 | Active |
| Sep 15, 2017 | Elevators EVCAT1 | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Open |
| Sep 10, 2026 | ECB | Unknown: NOTE: AT TIME OF INSPECTION, I OBSERVED A TRASH TRUCK PARKED ON THE SIDEWALK WITHOUT ANY BARRIERS IN PLACE WHILE CONSTRUCTION DEBRIS IS BEING THROWN INTO THE BACK CREATING AN OBSTRUCTION FOR PEDESTRIANS AND VEH | Closed |
| Sep 10, 2026 | ECB | Unknown: NOTE: AT THE TIME OF INSPECTION, I OBSERVED WORKERS THROWING WHITE DEBRIS BAGS FROM THE SIDEWALK SHED INTO A TRUCK AT EXPOSURE #4, CONTRARY TO 3303.5.2. THIS CREATES A HAZARDOUS CONDITION FOR PEDESTRIANS AS A D | Closed |
| Sep 9, 2026 | DOB | CONSTRUCTION: SHED NO LONGER CODE COMPLIANT DUE TO BEING HIT BY A CAR. DAMAGE TO 9 VERTICAL MEMBERS. | Open |
| Sep 9, 2026 | DOB | IMMEDIATE EMERGENCY: REMEDY :.REPAIR SHED VERTICAL MEMBERS. IF OWNER FAILS TO DO SO | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 19, 2026, 4:32 AM ET. BBL 1012760051.