Brooklyn · Block 265 · Lot 43 · 11201

50 Court Street

13 floors · 128,000 sq ft · built 1913 · class O6 · owner of record: 50 Court Street Associates

19open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
164dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 43 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 128,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 164 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 164 days
Annual filing
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1139 days
Next cycle year 2029
Energy audit and retro-commissioning (2035) Likely applies
Local Law 87 · Calendar year 2035
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 265). Agency page

Dec 31, 2035
in 3330 days
Next due 2035
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-14 (Accepted). Agency page

On file2026 reports accepted
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $1,062,600 in late-filing or failure-to-file penalties. Agency page

On fileCycle 10 filing on record: SAFE (2025-11-04)

Open violations

ECB / OATH (1)
IssuedViolationHearingBalance
Apr 16, 2020Construction CLASS - 2
FAILURE TO MAINTAIN EXTERIOR FACADE AND APPURTENANCES.NOTE:ROOF TOP PARAPET WALLS ON THE SOUTH EAST ELEVA. AND BULKHEAD AND CHIMEY DISPLAY SPALLING BRICKFACE FROM TAR APPLICATION.ALSO CHIMNEY MASONRY DISPLAYS V
#35435645H
Jan 7, 2021
IN VIOLATION
$0
DOB (10)
IssuedViolationStatus
Feb 23, 2022HAZARDOUS CONDITION (FACADE)
CYCLE 9A UNSAFE REPORT FILED
#909608
DOB VIOLATION - ACTIVE
Dec 1, 2021FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2102099
DOB VIOLATION - ACTIVE
Apr 29, 2021FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2002893
DOB VIOLATION - ACTIVE
Mar 14, 2019CONSTRUCTION
STOP ALL WORK IMMEDIATELY, MAKE JOB SITE SAFE AND CONTACT THE BOROUGH COMMISSIONER AT 718 802-3677
#0203RH
DOB VIOLATION - ACTIVE
Mar 14, 2019CONSTRUCTION
STOP ALL WORK IMMEDIATELY MAKE JOB SITE SAFE, AND CONTACT THE BOROUGH COMM. OFFICEAT 718 802-3677
#0204RH
DOB VIOLATION - ACTIVE
Mar 2, 2019CONSTRUCTION
BORO. COMM. HAS ORDERED ALL WORK STOPPED UNDER PERMIT#321703714/REM: S TOP ALL WORK IMMEDIATELY MAKE THE SITE SAFE ONLY CONTACT BOROUGH COMM OFFICE
#0202RH
DOB VIOLATION - ACTIVE
May 31, 2017FACADE SAFETY PROGRAM

#HAZ86930
DOB VIOLATION - ACTIVE
May 26, 1999CONSTRUCTION
WORK WITHOUT A PERMIT. WORK NOTED: DEMOLITION OF PLASTER WALL SURFACES THRU-OUT PREMISES AT 2ND - 4TH FLOORS REMEDY: STOP ALL WORK, MAKE SITE SAFE, OBTAIN PERMITS. CONTACT THIS DEPT. (718) 802-3685 BEFORE RETURNING TO WORK
#02MJ10
VIOLATION WORK WITHOUT PERMIT - ACTIVE
Jun 15, 1998CONSTRUCTION
WORK WITHOUT A PERMIT. WORK NOTED: NEW SIDEWALK INSTALLED ON COURT AND JORALEMON ST OVER TRANSIT AUTHORITY PROPERTY. SIDEWALK SUPPORTED ON CORRUGATED METAL DECKING CONTRARY TO TRANSIT AUTHORITY SPECIFICATIONS. NOTE JOB#30063949 (NEW SIDEWALK) DISAPPROVED 6/5/97 REMEDY: FILE PLANS, OBTAIN PERMITS AND
#02SC03
VIOLATION WORK WITHOUT PERMIT - ACTIVE
Jan 15, 1998CONSTRUCTION
WORK WITHOUT A PERMIT - CREATING HAZARDOUS CONDITION NOTED. (1) ALT# 300639049 (NEW SIDEWALK) ON COURT STREET & JORALEMON ST. DISAPPROVED 6/5/97 (2)ALL WORK COMPLETED PRIOR TO INSPECTION 7/97 WITHOUT REQUIRED APP. & APPROVALS FROM NYC TRANSIT AUTHORITY. (3) DEFECTIVE AND NON-APP ROVED MATERIAL CORRU
#3PR01
VIOLATION WORK WITHOUT PERMIT - ACTIVE
DOB NOW Safety (8)
IssuedViolationStatus
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction
Active
Feb 23, 2022Facades FISPHAZ
CYCLE 9A UNSAFE REPORT FILED
Active
Dec 1, 2021Energy Grade - LL33 FTP-EN-EGRDEA
Active
Apr 29, 2021Energy Grade - LL33 FTP-EN-EGRDEA
Active
May 31, 2017Facades FISP
CYCLE 8A UNSAFE REPORT FILED
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 18, 2026, 5:18 AM ET. BBL 3002650043.